Effects of compressor frequency and heat exchanger geometry on dynamic performance characteristics of heat pump dryers

被引:20
|
作者
Choi, JunYoung [1 ]
Lee, DongChan [1 ]
Park, Myeong Hyeon [1 ]
Lee, Yongju [2 ]
Kim, Yongchan [1 ]
机构
[1] Korea Univ, Dept Mech Engn, Anam Ro 145, Seoul 02841, South Korea
[2] LG Elect Inc, H&A Co, Appliance R&D, Gasan Digital 1 Ro 51, Seoul 08592, South Korea
关键词
Heat pump dryer; Moisture extraction rate; Transient simulation; Finite volume method; MATHEMATICAL-MODEL; SPECIALTY CROPS; MASS-TRANSFER; TUMBLE DRYER; PART; CO2; SIMULATION; SYSTEM;
D O I
10.1016/j.energy.2021.121391
中图分类号
O414.1 [热力学];
学科分类号
摘要
A heat pump dryer (HPD) exhibits significant transient behaviors owing to the combined system of the heat pump cycle and closed-loop air cycle. However, a complete transient simulation for HPDs has not been yet developed owing to its complicated equations and lack of experimental data. In this study, a complete transient simulation of an HPD was developed using the finite volume method and was validated with experimental data, presenting validation errors less than 6.1%. Using the developed simulation model, the dynamic behavior and performance of the HPD were analyzed by varying operation modes and heat exchanger length. The operation mode with a higher compressor frequency showed a 16.5% higher moisture extraction rate (MER) due to the decreased drying time, whereas that with a lower frequency showed a 34.8% higher specific moisture extraction rate (SMER) due to the decreased energy consumption. As the heat exchanger length increased from 80% to 120%, the MER increased by 10% and the SMER increased by 14%. Additionally, as the compressor frequency increased, the optimum heat exchanger length for achieving maximum performance increased. In conclusion, the compressor control logic and heat exchanger length should be optimized according to the drying time, power consumption, and initial cost. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Effects of compressor frequency and heat exchanger geometry on dynamic performance characteristics of heat pump dryers
    Choi, JunYoung
    Lee, DongChan
    Park, Myeong Hyeon
    Lee, Yongju
    Kim, Yongchan
    Energy, 2021, 235
  • [2] CUMULATIVE EFFECTS OF OPERATION OF VAPOUR COMPRESSOR HEAT PUMP WITH GROUND HEAT EXCHANGER
    Hanuszkiewicz-Drapala, Malgorzata
    Skladzien, Jan
    RYNEK ENERGII, 2011, (05): : 58 - 65
  • [3] Performance and improvements in heat pump dryers
    Alves, O
    Strommen, I
    DRYING '96, VOL A, 1996, : 405 - 416
  • [4] Investigations of the performance of a heat pump with internal heat exchanger
    Róbert Sánta
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 8499 - 8508
  • [5] Investigations of the performance of a heat pump with internal heat exchanger
    Santa, Robert
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (15) : 8499 - 8508
  • [6] FLOW GEOMETRY AND HEAT EXCHANGER PERFORMANCE
    SHORT, BE
    CHEMICAL ENGINEERING PROGRESS, 1965, 61 (07) : 63 - &
  • [7] Effects of component arrangement and ambient and drying conditions on the performance of heat pump dryers
    Saensabai, P
    Prasertsan, S
    DRYING TECHNOLOGY, 2003, 21 (01) : 103 - 127
  • [8] The effects of ground heat exchanger parameters changes on geothermal heat pump performance - A review
    Noorollahi, Younes
    Saeidi, Reza
    Mohammadi, Mohammad
    Amiri, Ali
    Hosseinzadeh, Mehdi
    APPLIED THERMAL ENGINEERING, 2018, 129 : 1645 - 1658
  • [9] Exergy Characteristics of a Steam Compressor Heat Pump
    Malyshev, A. A.
    Malinina, O. S.
    Tatarenko, Y. V.
    Kireev, V. S.
    OIL AND GAS ENGINEERING (OGE-2019), 2019, 2141
  • [10] Heat Exchanger Network Design Considering the Heat Pump Performance
    Yang, Minbo
    Feng, Xiao
    Liu, Guilian
    PRES 2014, 17TH CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1-3, 2014, 39 : 1099 - +