Effect of crown-to-implant ratio and crown height space on marginal bone stress: a finite element analysis

被引:17
作者
da Rocha Ferreira, Jose Joaquim [1 ]
Machado, Luis Filipe Meira [2 ]
Oliveira, Jose Manuel [1 ]
Ramos, Joao Carlos Tomas [3 ]
机构
[1] Inst Sci & Innovat Mech & Ind Engn INEGI, Oporto, Portugal
[2] Univ Minho, Cte Math, Campus Azurem, P-4800058 Guimaraes, Portugal
[3] Univ Coimbra, Fac Med, Dept Dent Stomatol & Maxillofacial Surg, Av Bissaya Barreto Blocos de Celas, P-3000075 Coimbra, Portugal
关键词
SHORT DENTAL IMPLANTS; OSSEOINTEGRATED IMPLANTS; CROWN/IMPLANT RATIO; EXTERNAL HEXAGON; WIDE IMPLANTS; PROSTHESES; SURVIVAL; 15-YEAR; STRAIN; MODEL;
D O I
10.1186/s40729-021-00368-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Crown-to-implant ratio and crown height space, associated with the use of short implants, have been related with marginal bone loss. However, it is unclear which of the two entities would play the most important role on the bone remodelling process. Using a finite element analysis, the present work aims to help clarifying how those two factors contribute for the stress generation at the marginal bone level. A numerical model (reference model), with a crown-to-implant ratio of 4, was double validated and submitted to a numerical calculation. Then, it was modified in two different ways: (a) by decreasing the prosthetic height obtaining crown-to-implant ratios of 3, 2.5 and 2 and (b) by increasing the implants length obtaining a crown-to-implant ratio of 2.08. The new models were also submitted to numerical calculations. Results: The reference model showed a marginal bone stress of 96.9 MPa. The increase in the implants' length did not show statistically significant differences in the marginal bone stress (p-value = 0.2364). The decrease in the prosthetic height was accompanied with a statistically significant decrease in the marginal bone stresses (p-value = 2.2e- 16). Conclusions: The results represent a paradigm change as the crown height space appears to be more responsible for marginal bone stress than the high crown-to-implant ratios or the implants' length. New prosthetic designs should be attempted to decrease the stress generated at the marginal bone level.
引用
收藏
页数:15
相关论文
共 74 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]  
American Society for Testing and Materials, 2003, D63802A ASTM
[3]   Implant Survival and Crestal Bone Loss Around Extra-Short Implants Supporting a Fixed Denture: The Effect of Crown Height Space, Crown-to-Implant Ratio, and Offset Placement of the Prosthesis [J].
Anitua, Eduardo ;
Hamdan Alkhraist, Mohammad ;
Pinas, Laura ;
Begona, Leire ;
Orive, Gorka .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) :682-689
[4]   Short Dental Implants: A Systematic Review [J].
Annibali, S. ;
Cristalli, M. P. ;
Dell'Aquila, D. ;
Bignozzi, I. ;
La Monaca, G. ;
Pilloni, A. .
JOURNAL OF DENTAL RESEARCH, 2012, 91 (01) :25-32
[5]   PHOTOELASTIC STRESS ANALYSIS OF EXTERNAL VERSUS INTERNAL IMPLANT-ABUTMENT CONNECTIONS [J].
Asvanund, Pattapon ;
Morgano, Steven M. .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (04) :266-271
[6]  
Avinent, 2013, INF ESTR FRES CRCO
[7]   In vivo evaluation of occlusalcontact area and maximum bite force in patients with various types of implant-supported prostheses [J].
Baca, Emrah ;
Yengin, Esengn ;
Gokcen-Rohlig, Bilge ;
Sato, Suichi .
ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (05) :1181-1187
[8]   TRIBOLOGICAL PROPERTIES OF TITANIUM-ALLOYS [J].
BUDINSKI, KG .
WEAR, 1991, 151 (02) :203-217
[9]   Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis [J].
Bulaqi, Haddad Arabi ;
Mashhadi, Mahmoud Mousavi ;
Safari, Hamed ;
Samandari, Mohammad Mahdi ;
Geramipanah, Farideh .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (06) :548-557
[10]  
Carlsson Gunnar E, 2004, Gerodontology, V21, P65, DOI 10.1111/j.1741-2358.2004.00005.x