Variations in cone beam CT numbers as a function of patient size: In vivo demonstration in bladder cancer patients

被引:7
作者
Mullen, Ajit [1 ,4 ]
Kron, Tomas [1 ,4 ]
Thomas, Jessica [2 ]
Foroudi, Farshad [3 ,5 ]
机构
[1] Peter MacCallum Canc Ctr, Dept Phys Sci, Melbourne, Vic 3002, Australia
[2] Peter MacCallum Canc Ctr, Ctr Biostat & Clin Trials, Melbourne, Vic 3002, Australia
[3] Peter MacCallum Canc Ctr, Dept Radiat Oncol, Melbourne, Vic 3002, Australia
[4] RMIT Univ, Melbourne, Vic, Australia
[5] Univ Melbourne, Dept Pathol, Parkville, Vic 3052, Australia
关键词
bladder cancer; cone-beam CT; dose calculation; Hounsfield numbers; radiation therapy;
D O I
10.1111/j.1754-9485.2010.02203.x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
P>We determined Hounsfield numbers, using cone beam CT (CBCT), in the bladder of 27 muscle invasive bladder cancer patients treated with online adaptive radiotherapy using a Varian linear accelerator. The CBCT number of urine was found to increase by 130 from the thinnest to the largest patient (249 mm to 346 mm average diameter) demonstrating the effect of patient size on Hounsfield number in CBCT in vivo.
引用
收藏
页码:505 / 507
页数:3
相关论文
共 9 条
[1]   A quality assurance program for image quality of cone-beam CT guidance in radiation therapy [J].
Bissonnette, Jean-Pierre ;
Moseley, Douglas J. ;
Jaffray, David A. .
MEDICAL PHYSICS, 2008, 35 (05) :1807-1815
[2]   Offline adaptive radiotherapy for bladder cancer using cone beam computed tomography [J].
Foroudi, F. ;
Wong, J. ;
Haworth, A. ;
Baille, A. ;
McAlpine, J. ;
Rolfo, A. ;
Kron, T. ;
Roxby, P. ;
Paneghel, A. ;
Williams, S. ;
Duchesne, G. ;
Tai, K. H. .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2009, 53 (02) :226-233
[3]   Compensators for dose and scatter management in cone-beam computed tomography [J].
Graham, S. A. ;
Moseley, D. J. ;
Siewerdsen, J. H. ;
Jaffray, D. A. .
MEDICAL PHYSICS, 2007, 34 (07) :2691-2703
[4]   Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy [J].
Hatton, Joan ;
McCurdy, Boyd ;
Greer, Peter B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15) :N329-N346
[5]  
RASBAND W, 2008, IMAGEJ PUBLIC DOMAIN
[6]   A new method for x-ray scatter correction:: first assessment on a cone-beam CT experimental setup [J].
Rinkel, J. ;
Gerfault, L. ;
Esteve, F. ;
Dinten, J-M .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15) :4633-4652
[7]   Simple methods to reduce patient dose in a Varian cone beam CT system for delivery verification in pelvic radiotherapy [J].
Roxby, P. ;
Kron, T. ;
Foroudi, F. ;
Haworth, A. ;
Fox, C. ;
Mullen, A. ;
Cramb, J. .
BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (982) :855-859
[8]   A simple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT [J].
Siewerdsen, JH ;
Daly, MJ ;
Bakhtiar, B ;
Moseley, DJ ;
Richard, S ;
Keller, H ;
Jaffray, DA .
MEDICAL PHYSICS, 2006, 33 (01) :187-197
[9]   Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning [J].
Yoo, Sua ;
Yin, Fang-Fang .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (05) :1553-1561