A low power detection method for small ultrasonic echo signals

被引:0
|
作者
Dijkstra, EA [1 ]
Olthuis, W [1 ]
Holsheimer, J [1 ]
Bergveld, P [1 ]
机构
[1] Univ Twente, Res Inst, MESA, NL-7500 AE Enschede, Netherlands
来源
SENSOR TECHNOLOGY IN THE NETHERLANDS: STATE OF THE ART | 1998年
关键词
piezoelectric transducer; ultrasound; spinal cord stimulation; signal processing;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Spinal cord stimulation is used for the management of chronic, intractable pain and vascular insufficiency. However, when stimulating at a constant voltage, the current density in the spinal cord changes due to the varying separation d between the spinal cord and the stimulating electrode, thus, preventing a stable clinical effect. Ln order to control the stimulation of spinal nerve fibers, a closed-loop system using ultrasonic delay time detection is being developed. This system is based on pulse-echo measurements using a piezoelectric transducer. The spinal cord stimulation system is an implanted system. Therefore, low power consumption (mu W) is an important requirement. A low power electronic circuit is developed to detect the small echo signals (mV) from the spinal cord. The detection method is based on amplitude demodulation of the echo signal. The method is simulated in MATLAB, and the simulation results are compared to the results of a simulated matched filter method. The amplitude demodulation method shows results similar to the matched filter method.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 50 条
  • [41] Transmission and detection of light diffraction signal by low-frequency ultrasonic wave
    Sakoda, T
    Sonoda, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2003, 42 (9A): : 5821 - 5825
  • [42] Detection of ultrasonic cavitation based on low-frequency analysis of acoustic signal
    Brabec, Kamil
    Mornstein, Vojtech
    CENTRAL EUROPEAN JOURNAL OF BIOLOGY, 2007, 2 (02): : 213 - 221
  • [43] Time series anomaly detection in power electronics signals with recurrent and ConvLSTM autoencoders
    Radaideh, Majdi I.
    Pappas, Chris
    Walden, Jared
    Lu, Dan
    Vidyaratne, Lasitha
    Britton, Thomas
    Rajput, Kishansingh
    Schram, Malachi
    Cousineau, Sarah
    DIGITAL SIGNAL PROCESSING, 2022, 130
  • [44] A naked-eyes detection method and the influence of solid particles for the ultrasonic cavitation
    Jian Liu
    Shixing Wang
    Chenhui Liu
    Libo Zhang
    Wentong Sun
    Chemical Papers, 2021, 75 : 6389 - 6397
  • [45] Method of Processing Ultrasonic In-line Monitoring Signals in Polymer Mixing Extrusion to Determine Mixing State
    Zhao, Xia
    Chen, Youxing
    Wang, Zhaoba
    Jin, Yong
    Liu, Bin
    JOURNAL OF TESTING AND EVALUATION, 2015, 43 (03) : 582 - 586
  • [46] A naked-eyes detection method and the influence of solid particles for the ultrasonic cavitation
    Liu, Jian
    Wang, Shixing
    Liu, Chenhui
    Zhang, Libo
    Sun, Wentong
    CHEMICAL PAPERS, 2021, 75 (12) : 6389 - 6397
  • [47] Ultrasonic thyroid nodule detection method based on U-Net network
    Chu, Chen
    Zheng, Jihui
    Zhou, Yong
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 199
  • [48] Quantitative detection method of plate structure defects based on ultrasonic local resonance
    Jiao J.
    Li L.
    Ma B.
    He C.
    Wu B.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (12): : 1 - 8
  • [49] Mathematical analysis of the echo-impulse position detection by the dual-frequency sensing method
    Shulgina, Y., V
    Soldatov, A., I
    Shulgin, E. M.
    Rozanova, Y., V
    Kroening, M.
    2014 INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING, AUTOMATION AND CONTROL SYSTEMS (MEACS), 2014,
  • [50] Pulse-echo ultrasound method for detection of post-menopausal women with osteoporotic BMD
    Karjalainen, J. P.
    Riekkinen, O.
    Kroger, H.
    OSTEOPOROSIS INTERNATIONAL, 2018, 29 (05) : 1193 - 1199