Indices of cardiovascular function derived from peripheral pulse wave analysis using radial applanation tonometry: a measurement repeatability study

被引:59
作者
Crilly, Mike
Coch, Christoph
Bruce, Margaret
Clark, Hazel
Williams, David
机构
[1] Univ Aberdeen, Sch Med, Dept Publ Hlth, Aberdeen AB25 2ZD, Scotland
[2] Bonn Univ Hosp, Dept Clin Pharmacol, Bonn, Germany
[3] Aberdeen Royal Infirm, Dept Clin Pharmacol, Aberdeen, Scotland
关键词
applanation tonometry; measurement error; pulse wave analysis; radial artery; reproducibility; ARTERIAL STIFFNESS; BLOOD-PRESSURE; AUGMENTATION INDEX; AORTIC PRESSURE; REPRODUCIBILITY; REFLECTIONS; RISK;
D O I
10.1177/1358863x07081134
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Pulse wave analysis (PWA) using applanation tonometry is a non-invasive technique for assessing cardiovascular function. It produces three important indices: ejection duration index (ED%), augmentation index adjusted for heart rate (AIX@75), and subendocardial viability ratio (SEVR%). The aim of this study was to assess within- and between-observer repeatability of these measurements. After resting supine for 15 minutes, 20 ambulant patients (16 male) in sinus rhythm underwent four PWA measurements on a single occasion. Two nurses (A & B) independently and alternately undertook PWA measurements using the same equipment (Omron HEM-757; SphygmoCor with Millar hand-held tonometer) blind to the other nurse's PWA measurements. Within- and between-observer differences were analysed using the Bland-Altman 'limits of agreement' approach (mean difference +/- 2 standard deviations, 2SD). Mean age was 56 (blood pressure, BP 136/79; pulse rate 64). BP/PWA measurements remained stable during assessment. Based on the average of two PWA measurements the mean 2SD between-observer difference in ED% was 0.3 +/- 2.0; AIX@75 1.0 +/- 3.9; and SEVR% 1.7 +/- 14.2. Based on a single PWA measurement the between-observer difference was ED% 0.3 +/- 3.3; AIX@75 1.7 +/- 6.9; and SEVR% 0.6 +/- 22.6. Within-observer differences for nurse-A were ED% 0.0 +/- 5.4; AIX@75 1.5 +/- 7.0; and SEVR% 1.7 +/- 39.0 (nurse-B: 0.1 +/- 3.8; 0.1 +/- 8.0; and 0.6 +/- 23.3, respectively). PWA demonstrates high levels of repeatability even when used by relatively inexperienced staff and has the potential to be included in the routine cardiovascular assessment of ambulant patients.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 25 条
[1]  
Altman D., 2000, Statistics with confidence intervals and statistical guidelines"
[2]   Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[3]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[4]   EXPERIMENTAL SUBENDOCARDIAL ISCHEMIA IN DOGS WITH NORMAL CORONARY-ARTERIES [J].
BUCKBERG, GD ;
ARCHIE, JP ;
FIXLER, DE ;
HOFFMAN, JIE .
CIRCULATION RESEARCH, 1972, 30 (01) :67-+
[5]   Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT [J].
El Assaad, MA ;
Topouchian, JA ;
Asmar, RG .
BLOOD PRESSURE MONITORING, 2003, 8 (03) :127-133
[6]   Reproducibility of radial pulse wave analysis in healthy subjects [J].
Filipovsky, J ;
Svobodová, V ;
Pecen, L .
JOURNAL OF HYPERTENSION, 2000, 18 (08) :1033-1040
[7]   Pulse-wave morphology and pulse-wave velocity in healthy human volunteers: Examination conditions [J].
Frimodt-Moller, M. ;
Nielsen, A. H. ;
Kamper, A-L. ;
Strandgaard, S. .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2006, 66 (05) :385-394
[8]   Assessment of endothelial function using peripheral waveform analysis - A clinical application [J].
Hayward, CS ;
Kraidly, M ;
Webb, CM ;
Collins, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (03) :521-528
[9]   MYOCARDIAL SUPPLY/DEMAND RATIO - CRITICAL-REVIEW [J].
HOFFMAN, JIE ;
BUCKBERG, GD .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (02) :327-332
[10]   Arterial wave reflections and survival in end-stage renal failure [J].
London, GM ;
Blacher, J ;
Pannier, B ;
Guérin, AP ;
Marchais, SJ ;
Safar, ME .
HYPERTENSION, 2001, 38 (03) :434-438