DM make up water reduction in thermal power plants using Six Sigma DMAIC methodology

被引:0
作者
Kaushik, Prabhakar [1 ]
Khanduja, Dinesh [2 ]
机构
[1] NC Engn Coll, Dept Mech Engn, Israna 132107, Paniput, India
[2] Natl Inst Technol, Dept Mech Engn, Kurukshetra 136119, Haryana, India
来源
JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH | 2008年 / 67卷 / 01期
关键词
CTQ; DM; DMAIC; process industry; six sigma;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Six Sigma DMAIC (define, measure, analysis, improve, control) methodology has been applied to a process industry seeking energy conservation, taking a specific case of a thermal power plant. DM (De-mineralize) water in these plants is an expensive input material. It has been found that 0.1% increase in DM make up water consumption increases generation cost by Rs 82.82 lakhs per annum. In present study, implementation of Six Sigma project recommendations brought down mean make up water from 0.90% to 0.54% of MCR (Maximum Continuous Rating), accruing with it a comprehensive energy savings of nearly Rs 304.77 laklis per annum.
引用
收藏
页码:36 / 42
页数:7
相关论文
共 9 条
[1]  
Coronado R.B., 2002, TQM MAGAZINE, V14, P92, DOI DOI 10.1108/09544780210416702
[2]  
HENDERSON KM, 2000, BENCHMARKING INT J, V7, P260, DOI DOI 10.1108/14635770010378909
[3]  
Kapur K. C., 2005, International Journal of Six Sigma and Competitive Advantage, V1, P210, DOI 10.1504/IJSSCA.2005.006426
[4]  
KUMAR P, 2002, PROD J, V43, P196
[5]   Confluence of six sigma, simulation and software development [J].
Mahanti, Rupa ;
Antony, Jiju .
MANAGERIAL AUDITING JOURNAL, 2005, 20 (07) :739-+
[6]  
MATHEW H, 2005, INT J 6 SIGMA COMP A, V1, P121
[7]  
Pandey P, 2000, 6 SIGMA WAY GE MOTOR
[8]  
Park S. H., 2002, PRODUCTIVITY, V43, P173
[9]   Six Sigma: concepts, tools, and applications [J].
Raisinghani, MS ;
Ette, H ;
Pierce, R ;
Cannon, G ;
Daripaly, P .
INDUSTRIAL MANAGEMENT & DATA SYSTEMS, 2005, 105 (3-4) :491-505