An alternative approach to the response function of Si(Li) X-ray detectors based on XPS study of silicon and front contact materials

被引:25
作者
Papp, T
Campbell, JL [1 ]
Varga, D
Kalinka, G
机构
[1] Univ Guelph, Dept Phys, Guelph, ON N1G 2W1, Canada
[2] Hungarian Acad Sci, Inst Nucl Res, H-4001 Debrecen, Hungary
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1016/S0168-9002(98)00339-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In a study of various Si(Li) X-ray detectors, strong variations of the response function were observed. In order to develop a physical understanding of the details of the response function, the photoelectron and Auger electron spectra of silicon generated by copper K alpha and silver L alpha X-rays were measured with a high-energy, high-resolution, electron spectrometer. The electron spectra of two of the variously reported front contact materials (gold and nickel) were also studied. Correspondence between these electron spectra and various components of the Si(Li) X-ray detector response function is proposed. Unavoidable contributions to the low-energy tails of the response function of a very good quality Si(Li) X-ray detector can be derived from the measured electron spectra. The peculiarity of the 5-10 keV photoelectron spectra of Si is the large plasmon loss peaks. The obtained electron spectra provide a background for testing the individual processes in Monte Carlo simulations of Si(Li) detectors, Si drift counters and CCD detectors. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:109 / 122
页数:14
相关论文
共 47 条
[21]   DESCRIPTION OF LOW-ENERGY PEAK DISTORTION OBSERVED IN X-RAY SPECTROMETRY WITH SI(LI) DETECTORS [J].
HECKEL, J ;
SCHOLZ, W .
X-RAY SPECTROMETRY, 1987, 16 (04) :181-185
[22]  
HOPKINSON GR, 1997, NUCL INSTRUM METHODS, V142, P213
[23]   RESPONSE FUNCTIONS OF A SI(LI) DETECTOR FOR 1.3-4.0 KEV MONOCHROMATIC PHOTONS [J].
INAGAKI, Y ;
SHIMA, K ;
MAEZAWA, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 27 (03) :353-359
[24]  
INAGAKI Y, 1996, 9517 KEK, P43
[25]   THE ENERGY DISPERSIVE-X-RAY DETECTOR - A QUANTITATIVE MODEL [J].
JOY, DC .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (09) :1772-1779
[26]   ENTRANCE WINDOW STRUCTURE OF A SI(LI) DETECTOR [J].
KALINKA, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 88 (04) :470-484
[27]   COMPLETE CHARACTERIZATION OF A SI(LI) DETECTOR IN THE PHOTON ENERGY-RANGE 0.9-5-KEV [J].
KRUMREY, M ;
TEGELER, E ;
ULM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :2287-2290
[28]  
Lepy MC, 1997, X-RAY SPECTROM, V26, P195, DOI 10.1002/(SICI)1097-4539(199707)26:4<195::AID-XRS212>3.0.CO
[29]  
2-5
[30]   ENTRANCE WINDOWS IN GERMANIUM LOW-ENERGY X-RAY DETECTORS [J].
LLACER, J ;
HALLER, EE ;
CORDI, RC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) :53-60