Integrated impacts of turbulent mixing and NOX-O3 photochemistry on reactive pollutant dispersion and intake fraction in shallow and deep street canyons

被引:66
作者
Zhang, Keer [1 ]
Chen, Guanwen [1 ]
Zhang, Yong [1 ]
Liu, Shanhe [1 ]
Wang, Xuemei [2 ]
Wang, Baoming [1 ]
Hang, Jian [1 ]
机构
[1] Sun Yat Sen Univ, Guangdong Prov Key Lab Climate Change & Nat Disas, Sch Atmospher Sci, Guangzhou, Peoples R China
[2] Jinan Univ, Inst Environm & Climate Res, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Computational fluid dynamics (CFD) simulation; Deep street canyon; Elevated-building design; Wind catcher; Reactive pollutant exposure; Personal intake fraction (P_IF); BUILDING INTAKE FRACTION; PEDESTRIAN-LEVEL WIND; LARGE-EDDY SIMULATION; CITY BREATHABILITY; URBAN CANOPY; AIR-QUALITY; NUMERICAL-SIMULATION; POPULATION EXPOSURE; VENTILATION; FLOW;
D O I
10.1016/j.scitotenv.2019.135553
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We employ computational fluid dynamics (CFD) simulations with NO-NO2-O-3 chemistry to investigate the impacts of aspect ratios (H/W = 1,3,5), elevated-building design, wind catchers and two background ozone concentrations ([O-3](b) = 100/20 ppb) on reactive pollulant. dispersion in two-dimensional (2D) street canyons. Personal intake fraction of NO2 (P_IFNO2) and its spatial mean value in entire street. (i.e. street intake fraction < P_IFNO2 >) are calculated to quantity pollutant exposure in near-road buildings. Chemical reaction contribution of NO2 exposure (CRC < P_IF >), O-3 depletion rate (d(ozone)) and photostationary state defect (delta(ps)) are used to analyze the interplay of turbulent and chemical processes. As H/W increases from 1,3 to 5 with [O-3](b) = 100 ppb, the flow pattern turns from single-main-vortex structure to two-counter-rotating-vortex structure, and pedestrian-level velocity becomes 1-2 orders smaller. The high-regions d(ozone) and low-vertical bar delta(ps)vertical bar regions get larger with more complete chemical reactions. Consequently, passive < P_IFNO2 > rises 1 order (4.09-5.71 ppm to 41.76 ppm), but reactive < P_IFNO2 > only increases several times (17.80-21.28 ppm to 58.50 ppm) and the contribution of chemistry (CRC < P_IF >) decreases with higher H/W. Thus, chemistry raises < P_IFNO2 > more effectively in shallow street canyons (H/W = 1-3). In deep street canyons (H/W = 5), elevated-building design and wind catchers destroy two-counter-rotating-vortex structure, improve street ventilation and reduce passive < P_IFNO2 > by 2 and 1 orders (41.76 ppm to 0.38-5.16 ppm), however they only reduce reactive < P_IFNO2 > by about 97.5% and 75% (5850 ppm to 1.61-14.48 ppm). Such building techniques induce lower O-3 depletion rate but greater chemical contribution. Finally, raising [O-3](b) from 20 to 100 ppb causes greater O-3 depletion rate and chemical contribution and produces larger < P_IFNO2 >. For deep street canyons, the impact of higher [O-3](b) on < P_IFNO2 > is weaker than that in shallow street canyons, while it becomes stronger when fixing elevated-building design and wind catchers. This study provides some innovative findings on reactive pollutant exposure in 2D street canyons and offers effective CFD methodologies to evaluate pollutant exposure with more complicated chemistry and urban configurations. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:24
相关论文
共 75 条
  • [21] Fine particulate air pollution and hospital admission for cardiovascular and respiratory diseases
    Dominici, F
    Peng, RD
    Bell, ML
    Pham, L
    McDermott, A
    Zeger, SL
    Samet, JM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (10): : 1127 - 1134
  • [22] Effects of lift-up design on pedestrian level wind comfort in different building configurations under three wind directions
    Du, Yaxing
    Mak, Cheuk Ming
    Liu, Jianlin
    Xia, Qian
    Niu, Jianlei
    Kwok, K. C. S.
    [J]. BUILDING AND ENVIRONMENT, 2017, 117 : 84 - 99
  • [23] Urban air quality
    Fenger, J
    [J]. ATMOSPHERIC ENVIRONMENT, 1999, 33 (29) : 4877 - 4900
  • [24] Simulations of the dispersion of reactive pollutants in a street canyon, considering different chemical mechanisms and micromixing
    Garmory, A.
    Kim, I. S.
    Britter, R. E.
    Mastorakos, E.
    [J]. ATMOSPHERIC ENVIRONMENT, 2009, 43 (31) : 4670 - 4680
  • [25] Large eddy simulation of shading effects on NO2 and O3 concentrations within an idealised street canyon
    Grawe, David
    Cai, Xiao-Ming
    Harrison, Roy M.
    [J]. ATMOSPHERIC ENVIRONMENT, 2007, 41 (34) : 7304 - 7314
  • [26] Effect of uneven building layout on air flow and pollutant dispersion in non-uniform street canyons
    Gu, Zhao-Lin
    Zhang, Yun-Wei
    Cheng, Yan
    Lee, Shun-Cheng
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (12) : 2657 - 2665
  • [27] A CFD modeling study in an urban street canyon for ultrafine particles and population exposure: The intake fraction approach
    Habilomatis, George
    Chaloulakou, Archontoula
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 530 : 227 - 232
  • [28] The influence of street layouts and viaduct settings on daily carbon monoxide exposure and intake fraction in idealized urban canyons
    Hang, Jian
    Luo, Zhiwen
    Wang, Xuemei
    He, Lejian
    Wang, Baomin
    Zhu, Wei
    [J]. ENVIRONMENTAL POLLUTION, 2017, 220 : 72 - 86
  • [29] City breathability in medium density urban-like geometries evaluated through the pollutant transport rate and the net escape velocity
    Hang, Jian
    Wang, Qun
    Chen, Xieyuan
    Sandberg, Mats
    Zhu, Wei
    Buccolieri, Riccardo
    Di Sabatino, Silvana
    [J]. BUILDING AND ENVIRONMENT, 2015, 94 : 166 - 182
  • [30] The influence of building height variability on pollutant dispersion and pedestrian ventilation in idealized high-rise urban areas
    Hang, Jian
    Li, Yuguo
    Sandberg, Mats
    Buccolieri, Riccardo
    Di Sabatino, Silvana
    [J]. BUILDING AND ENVIRONMENT, 2012, 56 : 346 - 360