Evaluation of microplate immunocapture method for detection of Vibrio cholerae, Salmonella Typhi and Shigella flexneri from food

被引:7
作者
Fakruddin, Md. [1 ]
Hossain, Md. Nur [1 ]
Ahmed, Monzur Morshed [1 ]
机构
[1] BCSIR, IFST, Ind Microbiol Lab, Dhaka 1205, Bangladesh
来源
BMC MICROBIOLOGY | 2017年 / 17卷
关键词
Immunocapture; Microplate; Enrichment; Detection; Pathogen; Food; POLYMERASE-CHAIN-REACTION; IMMUNOMAGNETIC SEPARATION METHOD; ESCHERICHIA-COLI O157; RAPID DETECTION; SURFACE WATERS; PARAHAEMOLYTICUS; ENRICHMENT; LISTERIA; FECES; SP;
D O I
10.1186/s12866-017-1099-y
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Improved methods with better separation and concentration ability for detection of foodborne pathogens are in constant need. The aim of this study was to evaluate microplate immunocapture (IC) method for detection of Salmonella Typhi, Shigella flexneri and Vibrio cholerae from food samples to provide a better alternative to conventional culture based methods. Results: The IC method was optimized for incubation time, bacterial concentration, and capture efficiency. 6 h incubation and log 6 CFU/ml cell concentration provided optimal results. The method was shown to be highly specific for the pathogens concerned. Capture efficiency (CE) was around 100% of the target pathogens, whereas CE was either zero or very low for non-target pathogens. The IC method also showed better pathogen detection ability at different concentrations of cells from artificially contaminated food samples in comparison with culture based methods. Performance parameter of the method was also comparable (Detection limit-25 CFU/25 g; sensitivity 100%; specificity-96.8%; Accuracy-96.7%), even better than culture based methods (Detection limit-125 CFU/25 g; sensitivity 95.9%; specificity-97%; Accuracy-96.2%). Conclusion: The IC method poses to be the potential to be used as a method of choice for detection of foodborne pathogens in routine laboratory practice after proper validation.
引用
收藏
页数:9
相关论文
共 34 条
[1]  
[Anonymous], 2187212007 ISOTS
[2]  
[Anonymous], 215672004 ISO
[3]  
[Anonymous], 657912002 ISODIS
[4]  
Arbault P, 2014 M INT ASS FOOD
[5]  
Arbault P, 2014, Patent, Patent No. [2014140381A1, 2014140381]
[6]  
Biosci IJ., 2016, INT J BIOSCI, V8, P16, DOI [10.12692/ijb/8.2.16-24, DOI 10.12692/ijb/8.2.16-24]
[7]   An evaluation of rapid methods for detecting Escherichia coli O157 on beef carcasses [J].
Chapman, PA ;
Ashton, R .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2003, 87 (03) :279-285
[8]   Immunomagnetic separation and coagglutination of Vibrio parahaemolyticus with anti-flagellar protein monoclonal antibody [J].
Datta, S. ;
Janes, M. E. ;
Simonson, J. G. .
CLINICAL AND VACCINE IMMUNOLOGY, 2008, 15 (10) :1541-1546
[9]  
da Conceiçao RDD, 2008, BRAZ J MICROBIOL, V39, P173, DOI [10.1590/S1517-83822008000100034, 10.1590/S1517-838220080001000034]
[10]  
Fakruddin M., 2012, Asian Journal of Biological Sciences, V5, P76, DOI 10.3923/ajbs.2012.76.85