Combination of shear-wave elastography with ultrasonography for detection of breast cancer and reduction of unnecessary biopsies: a systematic review and meta-analysis

被引:27
|
作者
Park, Sun-young [1 ]
Kang, Bong Joo [2 ]
机构
[1] Natl Evidence Based Healthcare Collaborating Agcy, Devis New Hlth Technol Assessment, Seoul, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Radiol, 222 Banpo Daero, Seoul 06591, South Korea
关键词
Shear wave elastography; Ultrasound; Breast; BI-RADS CLASSIFICATION; DIFFERENTIAL-DIAGNOSIS; ULTRASOUND ELASTOGRAPHY; CLINICAL-APPLICATION; QUANTITATIVE ELASTOGRAPHY; BENIGN; LESIONS; MASSES; PERFORMANCE; SWE;
D O I
10.14366/usg.20058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study was undertaken to compare the diagnostic performance and biopsy reduction rate of combined shear-wave elastography (SWE) and B-mode ultrasonography (US) versus B-mode US alone for breast lesions and to determine the most discriminatory parameter in SWE. Methods: A systematic review and meta-analysis were conducted. The resources for the study were obtained from MEDLINE, Embase, Cochrane Library, and KoreaMed on August 17, 2018. The quality of the articles was evaluated using the Scottish Intercollegiate Guidelines Network (SIGN) tool. Results: Twenty-five articles with 5,147 breast lesions were selected. The meta-analysis showed pooled sensitivities of 0.94 and 0.97 (P=0.087), pooled specificities of 0.85 and 0.61 (P=0.009), and area under the receiver operating characteristic curve (AUC) of 0.96 and 0.96 (P=0.095) for combined SWE and B-mode US versus B-mode US alone. When SWE was combined with B-mode US, the Breast Imaging Reporting and Data System category changed from 4 to 3 in 71.3% of the tests, decreasing the frequency of unnecessary biopsies by 41.1%. All four parameters of SWE (the color grade of lesion stiffness, maximum elasticity, mean elasticity, and color grade of lesion stiffness/homogeneity of the lesion) improved the specificity when they were added to B-mode US. The AUC for each SWE parameter was 0.99, 0.96, 0.96, and 0.93, respectively. Conclusion: Adding SWE to B-mode US not only provides additional diagnostic information for differentiating between benign and malignant breast lesions, but also decreases the likelihood of unnecessary biopsies.
引用
收藏
页码:318 / 332
页数:15
相关论文
共 50 条
  • [31] Value of shear-wave elastography in the diagnosis of symptomatic invasive lobular breast cancer
    Sim, Y. T.
    Vinnicombe, S.
    Whelehan, P.
    Thomson, K.
    Evans, A.
    CLINICAL RADIOLOGY, 2015, 70 (06) : 604 - 609
  • [32] Combined use of shear-wave elastography and Doppler ultrasonography in equivocal fibroepithelial lesions of the breast diagnosed by core needle biopsy
    Choi, Ji Soo
    Ko, Eun Young
    Kim, Min-Ji
    Ko, Eun Sook
    Han, Boo-Kyung
    ULTRASONOGRAPHY, 2023, 42 (01) : 31 - 40
  • [33] Shear-wave elastography to predict hepatocellular carcinoma after hepatitis C virus eradication: A systematic review and meta-analysis
    Esposto, Giorgio
    Santini, Paolo
    Galasso, Linda
    Mignini, Irene
    Ainora, Maria Elena
    Gasbarrini, Antonio
    Zocco, Maria Assunta
    WORLD JOURNAL OF GASTROENTEROLOGY, 2024, 30 (10) : 1450 - 1460
  • [34] Shear-wave elastosonography for diagnosis of prostatic cancer: a meta-analysis
    Chen, Ming
    Cao, Chun-Li
    Cui, Xin-Wu
    Huang, Shu-Yan
    Wang, Jia-Jia
    Cheng, Jing
    Li, Jun
    Li, Shu-Gang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (08): : 9533 - 9547
  • [35] Shear-Wave Elastography of the Breast: Added Value of a Quality Map in Diagnosis and Prediction of the Biological Characteristics of Breast Cancer
    Zheng, Xueyi
    Huang, Yini
    Liu, Yubo
    Wang, Yun
    Mao, Rushuang
    Li, Fei
    Cao, Longhui
    Zhou, Jianhua
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (02) : 172 - 180
  • [36] Prediction of invasive breast cancer using shear-wave elastography in patients with biopsy-confirmed ductal carcinoma in situ
    Bae, Jae Seok
    Chang, Jung Min
    Lee, Su Hyun
    Shin, Sung Ui
    Moon, Woo Kyung
    EUROPEAN RADIOLOGY, 2017, 27 (01) : 7 - 15
  • [37] Diagnostic Performance of Strain and Shear Wave Elastography for the Response to Neoadjuvant Chemotherapy in Breast Cancer Patients Systematic Review and Meta-Analysis
    Jin, Jian
    Liu, Yong Hong
    Zhang, Bo
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (10) : 2459 - 2466
  • [38] Diagnostic potential of real-time elastography (RTE) and shear wave elastography (SWE) to differentiate benign and malignant thyroid nodules: A systematic review and meta-analysis
    Hu, Xiangdong
    Liu, Yujiang
    Qian, Linxue
    MEDICINE, 2017, 96 (43)
  • [39] QUANTIFICATION OF ELASTIC HETEROGENEITY USING CONTOURLET-BASED TEXTURE ANALYSIS IN SHEAR-WAVE ELASTOGRAPHY FOR BREAST TUMOR CLASSIFICATION
    Zhang, Qi
    Xiao, Yang
    Chen, Shuai
    Wang, Congzhi
    Zhengy, Hairong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (02) : 588 - 600
  • [40] Correlation analysis between shear-wave elastography and pathological profiles in breast cancer
    Junnan Li
    Bo Sun
    Yanbo Li
    Shuang Li
    Jiahui Wang
    Ying Zhu
    Hong Lu
    Breast Cancer Research and Treatment, 2023, 197 : 269 - 276