Combination of shear-wave elastography with ultrasonography for detection of breast cancer and reduction of unnecessary biopsies: a systematic review and meta-analysis

被引:27
作者
Park, Sun-young [1 ]
Kang, Bong Joo [2 ]
机构
[1] Natl Evidence Based Healthcare Collaborating Agcy, Devis New Hlth Technol Assessment, Seoul, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Radiol, 222 Banpo Daero, Seoul 06591, South Korea
关键词
Shear wave elastography; Ultrasound; Breast; BI-RADS CLASSIFICATION; DIFFERENTIAL-DIAGNOSIS; ULTRASOUND ELASTOGRAPHY; CLINICAL-APPLICATION; QUANTITATIVE ELASTOGRAPHY; BENIGN; LESIONS; MASSES; PERFORMANCE; SWE;
D O I
10.14366/usg.20058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study was undertaken to compare the diagnostic performance and biopsy reduction rate of combined shear-wave elastography (SWE) and B-mode ultrasonography (US) versus B-mode US alone for breast lesions and to determine the most discriminatory parameter in SWE. Methods: A systematic review and meta-analysis were conducted. The resources for the study were obtained from MEDLINE, Embase, Cochrane Library, and KoreaMed on August 17, 2018. The quality of the articles was evaluated using the Scottish Intercollegiate Guidelines Network (SIGN) tool. Results: Twenty-five articles with 5,147 breast lesions were selected. The meta-analysis showed pooled sensitivities of 0.94 and 0.97 (P=0.087), pooled specificities of 0.85 and 0.61 (P=0.009), and area under the receiver operating characteristic curve (AUC) of 0.96 and 0.96 (P=0.095) for combined SWE and B-mode US versus B-mode US alone. When SWE was combined with B-mode US, the Breast Imaging Reporting and Data System category changed from 4 to 3 in 71.3% of the tests, decreasing the frequency of unnecessary biopsies by 41.1%. All four parameters of SWE (the color grade of lesion stiffness, maximum elasticity, mean elasticity, and color grade of lesion stiffness/homogeneity of the lesion) improved the specificity when they were added to B-mode US. The AUC for each SWE parameter was 0.99, 0.96, 0.96, and 0.93, respectively. Conclusion: Adding SWE to B-mode US not only provides additional diagnostic information for differentiating between benign and malignant breast lesions, but also decreases the likelihood of unnecessary biopsies.
引用
收藏
页码:318 / 332
页数:15
相关论文
共 50 条
[21]   Breast disease: Clinical application of US elastography for diagnosis [J].
Itoh, A ;
Ueno, E ;
Tohno, E ;
Kamma, H ;
Takahashi, H ;
Shiina, T ;
Yamakawa, M ;
Matsumura, T .
RADIOLOGY, 2006, 239 (02) :341-350
[22]   Principles and clinical application of ultrasound elastography for diffuse liver disease [J].
Jeong, Woo Kyoung ;
Lim, Hyo K. ;
Lee, Hyoung-Ki ;
Jo, Jae Moon ;
Kim, Yongsoo .
ULTRASONOGRAPHY, 2014, 33 (03) :149-160
[23]   Shear Wave Elastography: Is It a Valuable Additive Method to Conventional Ultrasound for the Diagnosis of Small (≤2 cm) Breast Cancer? [J].
Kim, So Jung ;
Ko, Kyung Hee ;
Jung, Hae Kyoung ;
Kim, Hyerin .
MEDICINE, 2015, 94 (42) :e1540
[24]   Potential role of shear-wave ultrasound elastography for the differential diagnosis of breast non-mass lesions: preliminary report [J].
Ko, Kyung Hee ;
Jung, Hae Kyoung ;
Kim, So Joong ;
Kim, Hyerin ;
Yoon, Jung Hyun .
EUROPEAN RADIOLOGY, 2014, 24 (02) :305-311
[25]   Role of shear-wave elastography (SWE) in complex cystic and solid breast lesions in comparison with conventional ultrasound [J].
Lee, Bo Eun ;
Chung, Jin ;
Cha, Eun-Suk ;
Lee, Jee Eun ;
Kim, Jeoung Hyun .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (07) :1236-1241
[26]   Breast Cancer Screening With Imaging: Recommendations From the Society of Breast Imaging and the ACR on the Use of Mammography, Breast MRI, Breast Ultrasound, and Other Technologies for the Detection of Clinically Occult Breast Cancer [J].
Lee, Carol H. ;
Dershaw, David ;
Kopans, Daniel ;
Evans, Phil ;
Monsees, Barbara ;
Monticciolo, Debra ;
Brenner, R. James ;
Bassett, Lawrence ;
Berg, Wendie ;
Feig, Stephen ;
Hendrick, Edward ;
Mendelson, Ellen ;
D'Orsi, Carl ;
Sickles, Edward ;
Burhenne, Linda Warren .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2010, 7 (01) :18-27
[27]   Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses? [J].
Lee, Eun Jung ;
Jung, Hae Kyoung ;
Ko, Kyung Hee ;
Lee, Jong Tae ;
Yoon, Jung Hyun .
EUROPEAN RADIOLOGY, 2013, 23 (07) :1803-1811
[28]   Added Value of Shear-Wave Elastography for Evaluation of Breast Masses Detected with Screening US Imaging [J].
Lee, Su Hyun ;
Chang, Jung Min ;
Kim, Won Hwa ;
Bae, Min Sun ;
Seo, Mirinae ;
Koo, Hye Ryoung ;
Chu, A. Jung ;
Gweon, Hye Mi ;
Cho, Nariya ;
Moon, Woo Kyung .
RADIOLOGY, 2014, 273 (01) :61-69
[29]   Two-View versus Single-View Shear-Wave Elastography: Comparison of Observer Performance in Differentiating Benign from Malignant Breast Masses [J].
Lee, Su Hyun ;
Cho, Nariya ;
Chang, Jung Min ;
Koo, Hye Ryoung ;
Kim, Jin You ;
Kim, Won Hwa ;
Bae, Min Sun ;
Yi, Ann ;
Moon, Woo Kyung .
RADIOLOGY, 2014, 270 (02) :344-353
[30]   Performance of Shear Wave Elastography for Differentiation of Benign and Malignant Solid Breast Masses [J].
Li, Guiling ;
Li, De-Wei ;
Fang, Yu-Xiao ;
Song, Yi-Jiang ;
Deng, Zhu-Jun ;
Gao, Jian ;
Xie, Yan ;
Yin, Tian-Sheng ;
Ying, Li ;
Tang, Kai-Fu .
PLOS ONE, 2013, 8 (10)