Combination of shear-wave elastography with ultrasonography for detection of breast cancer and reduction of unnecessary biopsies: a systematic review and meta-analysis

被引:27
作者
Park, Sun-young [1 ]
Kang, Bong Joo [2 ]
机构
[1] Natl Evidence Based Healthcare Collaborating Agcy, Devis New Hlth Technol Assessment, Seoul, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Radiol, 222 Banpo Daero, Seoul 06591, South Korea
关键词
Shear wave elastography; Ultrasound; Breast; BI-RADS CLASSIFICATION; DIFFERENTIAL-DIAGNOSIS; ULTRASOUND ELASTOGRAPHY; CLINICAL-APPLICATION; QUANTITATIVE ELASTOGRAPHY; BENIGN; LESIONS; MASSES; PERFORMANCE; SWE;
D O I
10.14366/usg.20058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study was undertaken to compare the diagnostic performance and biopsy reduction rate of combined shear-wave elastography (SWE) and B-mode ultrasonography (US) versus B-mode US alone for breast lesions and to determine the most discriminatory parameter in SWE. Methods: A systematic review and meta-analysis were conducted. The resources for the study were obtained from MEDLINE, Embase, Cochrane Library, and KoreaMed on August 17, 2018. The quality of the articles was evaluated using the Scottish Intercollegiate Guidelines Network (SIGN) tool. Results: Twenty-five articles with 5,147 breast lesions were selected. The meta-analysis showed pooled sensitivities of 0.94 and 0.97 (P=0.087), pooled specificities of 0.85 and 0.61 (P=0.009), and area under the receiver operating characteristic curve (AUC) of 0.96 and 0.96 (P=0.095) for combined SWE and B-mode US versus B-mode US alone. When SWE was combined with B-mode US, the Breast Imaging Reporting and Data System category changed from 4 to 3 in 71.3% of the tests, decreasing the frequency of unnecessary biopsies by 41.1%. All four parameters of SWE (the color grade of lesion stiffness, maximum elasticity, mean elasticity, and color grade of lesion stiffness/homogeneity of the lesion) improved the specificity when they were added to B-mode US. The AUC for each SWE parameter was 0.99, 0.96, 0.96, and 0.93, respectively. Conclusion: Adding SWE to B-mode US not only provides additional diagnostic information for differentiating between benign and malignant breast lesions, but also decreases the likelihood of unnecessary biopsies.
引用
收藏
页码:318 / 332
页数:15
相关论文
共 50 条
[1]   Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging-Preliminary Results [J].
Athanasiou, Alexandra ;
Tardivon, Anne ;
Tanter, Mickael ;
Sigal-Zafrani, Brigitte ;
Bercoff, Jeremy ;
Eux, Thomas Deffi ;
Gennisson, Jean-Luc ;
Fink, Mathias ;
Neuenschwander, Sylvia .
RADIOLOGY, 2010, 256 (01) :297-303
[2]   Diagnostic Performance of Quantitative Shear Wave Elastography in the Evaluation of Solid Breast Masses: Determination of the Most Discriminatory Parameter [J].
Au, Frederick Wing-Fa ;
Ghai, Sandeep ;
Moshonov, Hadas ;
Kahn, Harriette ;
Brennan, Cressida ;
Dua, Hemi ;
Crystal, Pavel .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (03) :W328-W336
[3]   Future of breast elastography [J].
Barr, Richard Gary .
ULTRASONOGRAPHY, 2019, 38 (02) :93-105
[4]   Shear-wave Elastography Improves the Specificity of Breast US: The BE1 Multinational Study of 939 Masses [J].
Berg, Wendie A. ;
Cosgrove, David O. ;
Dore, Caroline J. ;
Schaefer, Fritz K. W. ;
Svensson, William E. ;
Hooley, Regina J. ;
Ohlinger, Ralf ;
Mendelson, Ellen B. ;
Balu-Maestro, Catherine ;
Locatelli, Martina ;
Tourasse, Christophe ;
Cavanaugh, Barbara C. ;
Juhan, Valerie ;
Stavros, A. Thomas ;
Tardivon, Anne ;
Gay, Joel ;
Henry, Jean-Pierre ;
Cohen-Bacrie, Claude .
RADIOLOGY, 2012, 262 (02) :435-449
[5]   Clinical application of shear wave elastography (SWE) in the diagnosis of benign and malignant breast diseases [J].
Chang, Jung Min ;
Moon, Woo Kyung ;
Cho, Nariya ;
Yi, Ann ;
Koo, Hye Ryoung ;
Han, Wonsik ;
Noh, Dong-Young ;
Moon, Hyeong-Gon ;
Kim, Seung Ja .
BREAST CANCER RESEARCH AND TREATMENT, 2011, 129 (01) :89-97
[6]   Breast Mass Evaluation: Factors Influencing the Quality of US Elastography [J].
Chang, Jung Min ;
Moon, Woo Kyung ;
Cho, Nariya ;
Kim, Seung Ja .
RADIOLOGY, 2011, 259 (01) :59-64
[7]   Comparison of 3D and 2D shear-wave elastography for differentiating benign and malignant breast masses: focus on the diagnostic performance [J].
Choi, H. Y. ;
Sohn, Y. -M. ;
Seo, M. .
CLINICAL RADIOLOGY, 2017, 72 (10) :878-886
[8]   Shear Wave Elastography for Surgically Verified Breast Papillary Lesions: Is It Effective for Differentiation Between Benign and Malignant Lesions? [J].
Choi, Hye Jeong ;
Ko, Kyung Hee ;
Jung, Hae Kyoung .
JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (10) :2007-2014
[9]   Additional diagnostic value of shear-wave elastography and color Doppler US for evaluation of breast non-mass lesions detected at B-mode US [J].
Choi, Ji Soo ;
Han, Boo-Kyung ;
Ko, Eun Young ;
Ko, Eun Sook ;
Shin, Jung Hee ;
Kim, Ga Ram .
EUROPEAN RADIOLOGY, 2016, 26 (10) :3542-3549
[10]  
D'orsi C., 2013, Breast imaging reporting and data system: ACR BI-RADS breast imaging atlas