Effect of blockage ratio on critical velocity in tunnel model fire tests

被引:52
作者
Jiang, Xuepeng [1 ,2 ,3 ]
Zhang, Hongxin [1 ,2 ]
Jing, An [1 ,2 ]
机构
[1] Wuhan Univ Sci & Technol, Sch Resource & Environm Engn, Wuhan 430081, Hubei, Peoples R China
[2] Ind Safety Engn Technol Res Ctr Hubei Prov, Wuhan 430081, Hubei, Peoples R China
[3] Wuhan Univ Sci & Technol, Fire Safety Technol Inst, Wuhan 430081, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Critical velocity; Blockage ratio; Fire test; Fire location; SMOKE TEMPERATURE DISTRIBUTION; LONGITUDINAL VENTILATION; ROAD TUNNEL; SLOPING TUNNEL; FLOW; WIND; GAS;
D O I
10.1016/j.tust.2018.09.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experiments are conducted in a model tunnel of (1:20 of a tunnel section) to study the effect of blockage ratio on critical velocity. The vehicle blockage of the model tunnel is varied at 11 different blockage ratios, 9.4%, 15.6%, 21.9%, 25.0%, 31.3%, 34.4%, 40.7%, 43.8%, 50.1%, 56.3%, 59.5%. At the same time, the influence of heat loss in the experimental model on critical velocity is considered. The test results show that the critical velocity decreases with the increase of the blockage ratio, and the reduction ratio is less than the blockage ratio. The blockage-ratio modified coefficient obtained by experiment result is 0.545, and thus the formula of the critical velocity containing blockage ratio is proposed. The test results showed excellent agreement with from the formula of the critical velocity. The relationship between the critical velocity reduction ratio and the blockage ratio of this test and Oka and Atkinson (1995), Lee and Tsai (2012) and Kang (2010) were compared and analyzed. It is found that the main factors which lead to the different relationships about the critical velocity decrease rate and the blockage ratio are brought up, which include the height of fire burning surface, the location of fire source (the relative position about the fire source and blockage vehicles and whether the fire source is inside or outside the vehicle) and the lateral wall open area of vehicle.
引用
收藏
页码:584 / 591
页数:8
相关论文
共 23 条
[11]   Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires [J].
Li, Ying Zhen ;
Lei, Bo ;
Ingason, Haukur .
FIRE SAFETY JOURNAL, 2010, 45 (6-8) :361-370
[12]  
Liu C.C., 2015, FIRE SCI TECH, P925
[13]  
Liu Y., 2014, CASE STUD FIRE SAF C, V2, P16, DOI [10.1016/j.csfs.2014.09.001, DOI 10.1016/J.CSFS.2014.09.001]
[14]  
Mei X J, 2011, J SAFETY SCI TECHNOL, V7, P10
[15]   Numerical study on the optimization of smoke ventilation mode at the conjunction area between tunnel track and platform in emergency of a train fire at subway station [J].
Meng, Na ;
Hu, Longhua ;
Wu, Long ;
Yang, Lizhong ;
Zhu, Shi ;
Chen, Longfei ;
Tang, Wei .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2014, 40 :151-159
[16]   CFD analysis of a realistic reduced-scale modeling equipped with axial jet fan [J].
Musto, Marilena ;
Rotondo, Giuseppe .
FIRE SAFETY JOURNAL, 2015, 74 :11-24
[17]   Control of smoke flow in tunnel fires [J].
Oka, Y ;
Atkinson, GT .
FIRE SAFETY JOURNAL, 1995, 25 (04) :305-322
[18]   Effect of blockage-fire distance on buoyancy driven back-layering length and critical velocity in a tunnel: An experimental investigation and global correlations [J].
Tang, W. ;
Hu, L. H. ;
Chen, L. F. .
APPLIED THERMAL ENGINEERING, 2013, 60 (1-2) :7-14
[19]   Study on the critical velocity in a sloping tunnel fire under longitudinal ventilation [J].
Weng, Miao-cheng ;
Lu, Xin-ling ;
Liu, Fang ;
Du, Cheng-xian .
APPLIED THERMAL ENGINEERING, 2016, 94 :422-434
[20]   Control of smoke flow in tunnel fires using longitudinal ventilation systems - a study of the critical velocity [J].
Wu, Y ;
Bakar, MZA .
FIRE SAFETY JOURNAL, 2000, 35 (04) :363-390