Fine scale resolution of ceramic microstructures by X-ray computed tomography: An economical approach

被引:0
|
作者
Huss, SP [1 ]
Gray, JN [1 ]
Schilling, CH [1 ]
机构
[1] Iowa State Univ, Ames Lab, Ames, IA 50010 USA
来源
关键词
D O I
暂无
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
High-magnification, 3-dimensional imaging of ceramics by x-ray computed tomography (CT) typically requires use of a synchrotron and / or a massive array of solid-state detectors. The high cost of this research equipment generally limits its use as a process-development tool by ceramic manufacturers. In this paper, we demonstrate a more economical approach which produces image quality comparable to that of standard, high performance equipment. In this method we utilized an inexpensive image intensifier and applied techniques of frame averaging, gray-scale sub-ranging and other noise reduction and artifact removal methods in order to improve contrast sensitivity while maintaining low cost. After discussing critical factors affecting image quality, we discuss cost / performance tradeoffs associated with different CT equipment options.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [1] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [2] Microstructures characterization of TATB based granules by high resolution X-ray computed tomography
    Zhang, W.-B. (weibinzhang1@163.com), 1600, Editorial Board of Chinese Journal of Energetic Materials, P.O. Box 919-310, Mianyang, 621900, China (21):
  • [3] CERAMIC SCINTILLATORS FOR X-RAY COMPUTED-TOMOGRAPHY
    GRABMAIER, BC
    ROSSNER, W
    LEPPERT, J
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 1992, 130 (02): : K183 - K187
  • [4] Fine Scale Metrology on Cylindrical Structures using X-ray Micro-computed Tomography
    Roth, D. J.
    Rauser, R. W.
    Shin, E. E.
    Martin, R. E.
    Burke, C.
    MATERIALS EVALUATION, 2015, 73 (05) : 611 - 620
  • [5] High-resolution X-ray computed tomography of impactites
    Koeberl, C
    Denison, C
    Ketcham, RA
    Reimold, WU
    JOURNAL OF GEOPHYSICAL RESEARCH-PLANETS, 2002, 107 (E10)
  • [6] High-resolution x-ray luminescence computed tomography
    Lun, Michael C.
    Li, Changqing
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317
  • [7] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (01): : 36 - 41
  • [8] X-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13): : R29 - R43
  • [9] X-ray computed tomography
    Withers, Philip J.
    Bouman, Charles
    Carmignato, Simone
    Cnudde, Veerle
    Grimaldi, David
    Hagen, Charlotte K.
    Maire, Eric
    Manley, Marena
    Du Plessis, Anton
    Stock, Stuart R.
    NATURE REVIEWS METHODS PRIMERS, 2021, 1 (01):
  • [10] X-ray computed tomography
    Nature Reviews Methods Primers, 1