Comparison among Ocular Response Analyzer, Corvis ST and Goldmann applanation tonometry in healthy children

被引:14
作者
Salouti, Ramin [1 ]
Alishiri, Ali Agha [2 ]
Gharebaghi, Reza [1 ]
Naderi, Mostafa [2 ]
Jadidi, Khosmw [2 ]
Shojaei-Baghini, Ahmad [2 ]
Talebnejad, Mohammadreza [1 ]
Nasiri, Zahra [3 ]
Hosseini, Seyedmorteza [2 ]
Heidary, Fatemeh [4 ,5 ]
机构
[1] Shiraz Univ Med Sci, Dept Ophthalmol, Poostchi Ophthalmol Res Ctr, Shiraz 7134814336, Iran
[2] Baqiyatallah Univ Med Sci, Dept Ophthalmol, Tehran 141551856, Iran
[3] Tarbiat Modares Univ, Fac Math Sci, Tehran 141551856, Iran
[4] Shahid Beheshti Univ Med Sci, Ophthalm Res Ctr, Tehran 141551856, Iran
[5] Shahed Univ, Inununoregulat Res Ctr, Tehran 141551856, Iran
关键词
Goldmann applanation tonometer; Ocular Response Analyzer; Corvis ST; intraocular pressure; children; CORNEAL BIOMECHANICAL PROPERTIES; INTRAOCULAR-PRESSURE MEASUREMENT; THICKNESS;
D O I
10.18240/ijo.2018.08.13
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To explore the relationship between different parameters of Ocular Response Analyzer (ORA) and Corvis ST (CST) in a sample of healthy Iranian school-aged children and the relationship between parameters of these 2 instruments against intraocular pressure (IOP), measured by the Goldmann applanation tonometer (GAT-IOP), age and gender, and find possible correlation between ORA and CST with GAT. METHODS: This cross-sectional study included 90 healthy children. A general interview and complete eye examination were performed. Following successful GAT-IOP measurement, ORA and CST were conducted. The CST parameters were A 1/2 length (A1L, A2L), A 1/2 velocity (A1V, A2V), highest concavity deformation amplitude (HCDA), radius of curvature (RoC), peak distance (PD), central corneal thickness (CCT) and IOP. The ORA parameters were corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated IOP (IOP-G) and corneal compensated IOP (IOP-CC). Extracted data was analyzed using the Statistical Package for Social Science software. RESULTS: Totally 39 males with age of 9.08 +/- 1.60 (6-12) y and 51 females with age of 8.96 +/- 1.55 (6-13) y were included. Many CST parameters were significantly correlated with CH, CRF, IOP-G and IOP-CC. Some CST parameters had a significant correlation with GAT-IOP, including IOP-CST in both eyes and HCDA, A2L, PD, and RoC in the left eye, but none with age, except A2L in the right eye. The CRF measurement showed a significant correlation with GAT-IOP in both eyes and CH in the right eye, yet, none with age. Among all CST and ORA parameters, CCT-CST in both eyes and A1L in right eye had a significant correlation with gender, although this was a negligible negative correlation. Comparison of mean IOP values by different devices showed a significantly highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Also, IOP-G versus IOP-CST significantly had the lowest IOP overestimation among others. Overall, either low positive correlation or negligible correlation was found between IOP measurements by 3 instruments. CONCLUSION: The study finds the highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Overall, either low positive correlation or negligible correlation is found between IOP measurements by the 3 instruments.
引用
收藏
页码:1330 / 1336
页数:7
相关论文
共 50 条
[31]   Effectiveness of the Goldmann Applanation Tonometer, the Dynamic Contour Tonometer, the Ocular Response Analyzer and the Corvis ST in Measuring Intraocular Pressure following FS-LASIK [J].
Bao, Fangjun ;
Huang, Wei ;
Zhu, Rong ;
Lu, Nanji ;
Wang, Yuan ;
Li, Hechen ;
Wu, Songan ;
Lin, Huini ;
Wang, Junjie ;
Zheng, Xiaobo ;
Huang, JinHai ;
Li, Yiyu ;
Wang, Qinmei ;
Elsheikh, Ahmed .
CURRENT EYE RESEARCH, 2020, 45 (02) :144-152
[32]   Comparison of ICare, dynamic contour tonometer, and ocular response analyzer with Goldmann applanation tonometer in patients with glaucoma [J].
Vandewalle, Evelien ;
Vandenbroeck, Sofie ;
Stalmans, Ingeborg ;
Zeyen, Thierry .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (05) :783-789
[33]   Comparison of the Icare rebound tonometry with the Goldmann applanation tonometry in a pediatric population [J].
Grigorian, Florin ;
Grigorian, A. Paula ;
Li, Ang ;
Sattar, Abdus ;
Krishna, Rohit ;
Olitsky, Scott E. .
JOURNAL OF AAPOS, 2015, 19 (06) :572-574
[34]   Clinical comparison of the Icare tonometer and Goldmann applanation tonometry [J].
Pakrou, Nima ;
Gray, Tim ;
Mills, Richard ;
Landers, John ;
Craig, Jamie .
JOURNAL OF GLAUCOMA, 2008, 17 (01) :43-47
[35]   Goldmann Applanation Tonometer Versus Ocular Response Analyzer for Measuring Intraocular Pressure After Descemet Stripping Automated Endothelial Keratoplasty [J].
Feizi, Sepehr ;
Faramarzi, Amir ;
Masoudi, Ali ;
Azari, Amir A. ;
Veisi, Amirreza .
CORNEA, 2018, 37 (11) :1370-1375
[36]   Goldmann applanation tonometer versus ocular response analyzer for measuring intraocular pressure after congenital cataract surgery [J].
Feizi, Sepehr ;
Faramarzi, Amir ;
Kheiri, Bahareh .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (05) :582-589
[37]   Associations Between Diurnal Changes in Goldmann Tonometry, Corneal Geometry, and Ocular Response Analyzer Parameters [J].
Lau, William ;
Pye, David C. .
CORNEA, 2012, 31 (06) :639-644
[38]   Intraocular Pressure Before and After Corneal Refractive Surgery: A Prospective Comparison of Corvis ST and Ocular Response Analyzer [J].
Salouti, Ramin ;
Azimi, Ali ;
Meshksar, Aidin ;
Takapouy, Ramin ;
Ghoreyshi, Maryam ;
Salouti, Kia ;
Razeghinejad, Reza ;
Nowroozzadeh, Mohammad Hossein .
JOURNAL OF GLAUCOMA, 2024, 33 (10) :780-784
[39]   Methods for Intraocular Pressure Measurement: Evaluation of Agreement Between Goldmann Applanation Tonometry and Goldmann Correlated Intraocular Pressure With Reichert's Ocular Response Analyzer [J].
Fraser, C. E. ;
Ehrlich, J. R. ;
Haseltine, S. J. ;
Shimmyo, M. ;
Radcliffe, N. M. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
[40]   Agreement in central corneal thickness measurement between Corvis ST and ocular response analyzer [J].
Salouti, Ramin ;
Razeghinejad, Reza ;
Masihpour, Nasrin ;
Ghoreyshi, Maryam ;
Nowroozzadeh, M. Hossein .
INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (10) :2563-2567