Amperometric inhibition-based detection of organophosphorus pesticides in unary and binary mixtures employing flow-injection analysis

被引:20
|
作者
Marinov, Ivaylo [1 ]
Ivanov, Yavor [1 ]
Vassileva, Nastya [2 ]
Godjevargova, Tzonka [1 ]
机构
[1] Univ Prof Dr Assen Zlatarov, Dept Biotechnol, Burgas 8010, Bulgaria
[2] Univ Rousse Angel Kanchev Technol Coll, Dept Biotechnol & Food Prod, Razgrad 7200, Bulgaria
关键词
Amperometric biosensor; Immobilized acetylcholinesterase; Pesticides; Flow-injection system; THROUGH BIOSENSOR; ENZYME SENSOR; ACETYLCHOLINESTERASE; SYSTEM; CHOLINESTERASE; REACTIVATION; INSECTICIDE; PARAOXON; FOOD;
D O I
10.1016/j.snb.2011.09.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present work is focused on the application of an acetylthiocholine (ATCh) biosensor in a flow-injection system for the detection of organophosphorus pesticides. The optimal operating conditions of the flow-injection system were determined: flow-rate -0.5 mL min(-1), substrate concentration - 100 mu M, incubation and reactivation time-10 min. A calibration plot was obtained for ATCh concentration ranging from 20 to 200 mu M. A linear interval was detected along the calibration curve from 20 to 100 mu M with a correlation coefficient R(2) = 0.996. The sensitivity of the constructed biosensor was calculated to be 0.083 mu A mu M(-1) cm(-2). The application of the flow-injection system for detection and quantification of three organophosphorus pesticides - paraoxon ethyl, monocrotophos and dichlorvos in unary solutions and in binary mixtures was investigated as well. The inhibition curves for each pesticide was plotted and the linear intervals were determined along with the corresponding equations and detection limits -0.87 x 10(-11) M for paraoxon, 1.08 x 10(-11) M for monocrotophos and 1.22 x 10(-10) M for dichlorvos. The bimolecular inhibition constants k(i) were calculated by performing amperometric measurements of the residual enzyme activity after incubation for 10 min in a series of samples with varying pesticide concentrations (from 2 to 100 mu M). The highest inhibition potency was observed for paraoxon (2.3 x 10(5) M(-1) min(-1)), and the lowest - for dichlorvos (3.5 x 10(4) M(-1) min(-1)). The flow-injection system was used in the detection of anti-cholinesterase activity of two binary mixtures - paraoxon + monocrotophos and paraoxon + dichlorvos. It was interesting to observe that the total anti-cholinesterase activity of the mixtures was lower than the anti-cholinesterase activity of paraoxon with the same concentration in the sample. The storage stability of the enzyme membrane was considerably improved with respect to our previous work. After storage for 30 days, the enzyme membrane retained over 90% of its initial response. The half-life storage time of the enzyme membrane (50% residual activity) was almost tripled - from 25 to 75 days. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1098 / 1105
页数:8
相关论文
共 11 条
  • [1] FLOW-INJECTION SYSTEM WITH SITE-SPECIFIC IMMOBILIZATION OF ACETYLCHOLINESTERASE BIOSENSOR FOR AMPEROMETRIC DETECTION OF ORGANOPHOSPHATE PESTICIDES
    Ivanov, Yavor
    Marinov, Ivailo
    Portaccio, Marianna
    Lepore, Maria
    Mita, Damiano Gustavo
    Godjevargova, Tzonka
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2012, 26 (03) : 3044 - 3053
  • [2] Flow-injection amperometric determination of pesticides on the basis of their inhibition of immobilized acetylcholinesterases of different origin
    Jeanty, G
    Wojciechowska, A
    Marty, JL
    Trojanowicz, M
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (08) : 691 - 695
  • [3] A novel biosensor based on photoelectro-synergistic catalysis for flow-injection analysis system/amperometric detection of organophosphorous pesticides
    Wei, Yinyin
    Li, Ying
    Qu, Yunhe
    Xiao, Fei
    Shi, Guoyue
    Jin, Litong
    ANALYTICA CHIMICA ACTA, 2009, 643 (1-2) : 13 - 18
  • [4] Biomonitoring of Organophosphorus Agent Exposure by Reactivation of Cholinesterase Enzyme Based on Carbon Nanotube-Enhanced Flow-Injection Amperometric Detection
    Du, Dan
    Wang, Jun
    Smith, Jordan N.
    Timchalk, Charles
    Lin, Yuehe
    ANALYTICAL CHEMISTRY, 2009, 81 (22) : 9314 - 9320
  • [5] Prussian-Blue-based amperometric biosensors in flow-injection analysis
    Karyakin, AA
    Karyakina, EE
    Gorton, L
    TALANTA, 1996, 43 (09) : 1597 - 1606
  • [6] Amperometric biosensor based on immobilization acetyleholinesterase on manganese porphyrin nanoparticles for detection of trichlorfon with flow-injection analysis system
    Li, Xiao-Hua
    Xie, Zong-Hong
    Min, Hong
    Xian, Yne-Zhong
    Jin, Li-Tong
    ELECTROANALYSIS, 2007, 19 (24) : 2551 - 2557
  • [7] Biosensor based on acetylcholinesterase immobilized onto layered double hydroxides for flow injection/amperometric detection of organophosphate pesticides
    Gong, Jingming
    Guan, Zhangqiong
    Song, Dandan
    BIOSENSORS & BIOELECTRONICS, 2013, 39 (01): : 320 - 323
  • [8] Sensitive detection of organophosphorus pesticides using a needle type amperometric acetylcholinesterase-based bioelectrode. Thiocholine electrochemistry and immobilised enzyme inhibition
    Turdean, GL
    Popescu, IC
    Oniciu, L
    Thevenot, DR
    JOURNAL OF ENZYME INHIBITION AND MEDICINAL CHEMISTRY, 2002, 17 (02) : 107 - 115
  • [9] Simultaneous determination of tert-butylhydroquinone, propyl gallate, and butylated hydroxyanisole by flow-injection analysis with multiple-pulse amperometric detection
    Bavol, Dmytro
    Economou, Anastasios
    Zima, Jiri
    Barek, Jiri
    Dejmkova, Hana
    TALANTA, 2018, 178 : 231 - 236
  • [10] Simultaneous Determination of Caffeine, Ibuprofen, and Paracetamol by Flow-injection Analysis with Multiple-pulse Amperometric Detection on Boron-doped Diamond Electrode
    Chaves, Sandro C.
    Aguiar, Priscila N. C.
    Torres, Livia M. F. C.
    Gil, Eric S.
    Luz, Rita C. S.
    Damos, Flavio S.
    Munoz, Rodrigo A. A.
    Richter, Eduardo M.
    dos Santos, Wallans T. P.
    ELECTROANALYSIS, 2015, 27 (12) : 2785 - 2791