Evaluation and Improvement of Circumferential Uniformity for Blast Furnace Raceway

被引:9
作者
Tang, Jue [1 ,2 ]
Zhang, Zedong [1 ]
Shi, Quan [1 ]
Chu, Mansheng [3 ,4 ]
Lin, Anchuan [5 ]
Luo, Yingjie [5 ]
机构
[1] Northeastern Univ, Sch Met, 3-11 Wenhua Rd, Shenyang 110819, Peoples R China
[2] Northeastern Univ, Liaoning Prov Engn Res Ctr Technol Low Carbon Ste, 3-11 Wenhua Rd, Shenyang 110819, Peoples R China
[3] Northeastern Univ, State Key Lab Rolling & Automat, 3-11 Wenhua Rd, Shenyang 110819, Peoples R China
[4] Northeastern Univ, Key Lab Data Analyt & Optimizat Smart Ind, 3-11 Wenhua Rd, Shenyang 110819, Peoples R China
[5] Kun Steel Technol Ctr, 36 Gangkun Rd, Kuming 650302, Peoples R China
基金
中国国家自然科学基金;
关键词
blast furnace; tuyere; raceway; blast kinetic energy; circumferential uniformity; HEARTH; STATE; TEMPERATURE; PREDICTION; MODEL; SIZE;
D O I
10.2355/isijinternational.ISIJINT-2021-371
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The bustle pipe model of a running 2 500 m(3) blast furnace was established. The local and overall uniformity indexes of the raceway were defined and constructed. And then the effects of blast flow rate, the diameter and length of all tuyeres or No. 2 tuyere on the circumferential uniformity of raceway were quantitatively evaluated. It was shown that the circumferential uniformity of raceway decreased with the increasing blast flow rate, and when the blast flow rate increased from 4 300 m 3 /min to 4 700 m(3)/min, the circumferential uniformity index of raceway decreased from 0.1715 to 0.0760. The diameter of tuyere had a significant effect on the circumferential uniformity, while the length of tuyere showed little influence. The circumferential uniformity of raceway could be improved by increasing the diameter of all tuyeres or No. 2 tuyere with the minimum blast kinetic energy. When the diameter of all tuyeres increased to 140 mm, the overall uniformity index of raceway increased to 0.207, but the blast kinetic energy was only about 64 kJ/s which couldn't meet the smelting. requirement. While the diameter of No. 2 tuyere near the hot blast main increased to 126 mm, the overall uniformity of the raceway increased to 0.124, and the blast kinetic energy was 120.11 kJ/s which was still within the reasonable range. it was feasible to improve the circumferential uniformity of raceway by adjusting the diameter of one or some off-average tuyeres but not all.
引用
收藏
页码:477 / 486
页数:10
相关论文
共 24 条
  • [1] [陈辉 Chen Hui], 2011, [钢铁, Iron and Steel], V46, P22
  • [2] Improving the Junction Between the Hot-Blast Main and the Bustle Pipe of a Blast Furnace
    Druzhkov, V. G.
    Shirshov, M. Yu
    [J]. METALLURGIST, 2017, 60 (11-12) : 1239 - 1242
  • [3] Comparison of blast furnace raceway size with theory
    Gupta, G. S.
    Rudolph, V.
    [J]. ISIJ INTERNATIONAL, 2006, 46 (02) : 195 - 201
  • [4] Hua J. M., 2005, IRONMAKING, V24, P5
  • [5] Reconstruction of Three-dimensional Temperature Distribution with Radiative Image by Monte Carlo Method in Blast Furnace Raceway
    Li, Yan
    Cheng, Shusen
    Zhang, Ruixuan
    Zhou, Dongdong
    Chen, Tian
    [J]. ISIJ INTERNATIONAL, 2017, 57 (12) : 2141 - 2147
  • [6] Sensitive Influence of Floating State of Blast Furnace Deadman on Molten Iron Flow and Hearth Erosion
    Li, Yang-long
    Cheng, Shu-sen
    Zhang, Peng
    Zhou, Sheng-hua
    [J]. ISIJ INTERNATIONAL, 2015, 55 (11) : 2332 - 2341
  • [7] Uniformity of Blast-Furnace Parameters over the Perimeter
    Lyalyuk V.P.
    Tovarovskii I.G.
    Kassim D.A.
    [J]. Steel in Translation, 2018, 48 (3) : 179 - 184
  • [8] Improvement of the Uniformity of Blast Distribution over the Circumference of Blast-Furnace Hearth
    Lyalyuk, V. P.
    Tarakanov, A. K.
    Kassim, D. A.
    Riznitskii, I. G.
    [J]. METALLURGIST, 2018, 62 (1-2) : 119 - 124
  • [9] Lyalyuk V. P., 2020, FERROUS METALL, V76, P691, DOI [10.32339/0135-5910-2020-7-691-699, DOI 10.32339/0135-5910-2020-7-691-699]
  • [10] Malyshev A. A., 1964, METALLURGIST+, V8, P338, DOI [10.1007/ bf00748663, DOI 10.1007/BF00748663]