Feasibility of proton FLASH irradiation using a synchrocyclotron for preclinical studies

被引:88
作者
Darafsheh, Arash [1 ]
Hao, Yao [1 ]
Zwart, Townsend [2 ]
Wagner, Miles [2 ]
Catanzano, Daniel [2 ]
Williamson, Jeffrey F. [1 ]
Knutson, Nels [1 ]
Sun, Baozhou [1 ]
Mutic, Sasa [1 ]
Zhao, Tianyu [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
[2] Mevion Med Syst, 300 Foster St, Littleton, MA 01460 USA
关键词
FLASH; Monte Carlo; proton therapy; synchrocyclotron; ultrahigh dose rate; ELECTRON-BEAM DOSIMETRY; ION RECOMBINATION; PLATFORM;
D O I
10.1002/mp.14253
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: It has been recently shown that radiotherapy at ultrahigh dose rates (>40 Gy/s, FLASH) has a potential advantage in sparing healthy organs compared to that at conventional dose rates. The purpose of this work is to show the feasibility of proton FLASH irradiation using a gantry-mounted synchrocyclotron as a first step toward implementing an experimental setup for preclinical studies. Methods: A clinical Mevion HYPERSCAN(R)synchrocyclotron was modified to deliver ultrahigh dose rates. Pulse widths of protons with 230 MeV energy were manipulated from 1 to 20 mu s to deliver in conventional and ultrahigh dose rate. A boron carbide absorber was placed in the beam for range modulation. A Faraday cup was used to determine the number of protons per pulse at various dose rates. Dose rate was determined by the dose measured with a plane-parallel ionization chamber with respect to the actual delivery time. The integral depth dose (IDD) was measured with a Bragg ionization chamber. Monte Carlo simulation was performed in TOPAS as the secondary check for the measurements. Results: Maximum protons charge per pulse, measured with the Faraday cup, was 54.6 pC at 20 mu s pulse width. The measured IDD agreed well with the Monte Carlo simulation. The average dose rate measured using the ionization chamber showed 101 Gy/s at the entrance and 216 Gy/s at the Bragg peak with a full width at half maximum field size of 1.2 cm. Conclusions: It is feasible to deliver protons at 100 and 200 Gy/s average dose rate at the plateau and the Bragg peak, respectively, in a small similar to 1 cm(2)field using a gantry-mounted synchrocyclotron.
引用
收藏
页码:4348 / 4355
页数:8
相关论文
共 35 条
[21]   FLASH radiotherapy: Newsflash or flash in the pan? [J].
Maxim, Peter G. ;
Keall, Paul ;
Cai, Jing .
MEDICAL PHYSICS, 2019, 46 (10) :4287-4290
[22]   Long-term neurocognitive benefits of FLASH radiotherapy driven by reduced reactive oxygen species [J].
Montay-Gruel, Pierre ;
Acharya, Munjal M. ;
Petersson, Kristoffer ;
Alikhani, Leila ;
Yakkala, Chakradhar ;
Allen, Barrett D. ;
Ollivier, Jonathan ;
Petit, Benoit ;
Jorge, Patrik Goncalves ;
Syage, Amber R. ;
Nguyen, Thuan A. ;
Baddour, Al Anoud D. ;
Lu, Celine ;
Singh, Paramvir ;
Moeckli, Raphael ;
Bochud, Francois ;
Germond, Jean-Francois ;
Froidevaux, Pascal ;
Bailat, Claude ;
Bourhis, Jean ;
Vozenin, Marie-Catherine ;
Limoli, Charles L. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2019, 116 (22) :10943-10951
[23]   X-rays can trigger the FLASH effect: Ultra-high dose-rate synchrotron light source prevents normal brain injury after whole brain irradiation in mice [J].
Montay-Gruel, Pierre ;
Bouchet, Audrey ;
Jaccard, Maud ;
Patin, David ;
Serduc, Raphael ;
Aim, Warren ;
Petersson, Kristoffer ;
Petit, Benoit ;
Bailat, Claude ;
Bourhis, Jean ;
Brauer-Krisch, Elke ;
Vozenin, Marie-Catherine .
RADIOTHERAPY AND ONCOLOGY, 2018, 129 (03) :582-588
[24]   Irradiation in a flash: Unique sparing of memory in mice after whole brain irradiation with dose rates above 100 Gy/s [J].
Montay-Gruel, Pierre ;
Petersson, Kristoffer ;
Jaccard, Maud ;
Boivin, Gael ;
Germond, Jean-Francois ;
Petit, Benoit ;
Doenlen, Raphael ;
Favaudon, Vincent ;
Bochud, Francois ;
Bailat, Claude ;
Bourhis, Jean ;
Vozenin, Marie-Catherine .
RADIOTHERAPY AND ONCOLOGY, 2017, 124 (03) :365-369
[25]  
Moyers M. F., 2012, PRACTICAL IMPLEMENTA
[26]  
O'Neal III CD, 2014, US patent, Patent No. [14/184,990, 14184990]
[27]   Experimental Set-up for FLASH Proton Irradiation of Small Animals Using a Clinical System [J].
Patriarca, Annalisa ;
Fouillade, Charles ;
Auger, Michel ;
Martin, Frederic ;
Pouzoulet, Frederic ;
Nauraye, Catherine ;
Heinrich, Sophie ;
Favaudon, Vincent ;
Meyroneinc, Samuel ;
Dendale, Remi ;
Mazal, Alejandro ;
Poortmans, Philip ;
Verrelle, Pierre ;
De Marzi, Ludovic .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03) :619-626
[28]   TOPAS: An innovative proton Monte Carlo platform for research and clinical applications [J].
Perl, J. ;
Shin, J. ;
Schuemann, J. ;
Faddegon, B. ;
Paganetti, H. .
MEDICAL PHYSICS, 2012, 39 (11) :6818-6837
[29]   High dose-per-pulse electron beam dosimetry - A model to correct for the ion recombination in the Advanced Markus ionization chamber [J].
Petersson, Kristoffer ;
Jaccard, Maud ;
Germond, Jean-Francois ;
Buchillier, Thierry ;
Bochud, Francois ;
Bourhis, Jean ;
Vozenin, Marie-Catherine ;
Bailat, Claude .
MEDICAL PHYSICS, 2017, 44 (03) :1157-1167
[30]   Ultra-High-Dose-Rate FLASH Irradiation May Spare Hypoxic Stem Cell Niches in Normal Tissues [J].
Pratx, Guillem ;
Kapp, Daniel S. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01) :190-192