Feasibility of proton FLASH irradiation using a synchrocyclotron for preclinical studies

被引:79
作者
Darafsheh, Arash [1 ]
Hao, Yao [1 ]
Zwart, Townsend [2 ]
Wagner, Miles [2 ]
Catanzano, Daniel [2 ]
Williamson, Jeffrey F. [1 ]
Knutson, Nels [1 ]
Sun, Baozhou [1 ]
Mutic, Sasa [1 ]
Zhao, Tianyu [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
[2] Mevion Med Syst, 300 Foster St, Littleton, MA 01460 USA
关键词
FLASH; Monte Carlo; proton therapy; synchrocyclotron; ultrahigh dose rate; ELECTRON-BEAM DOSIMETRY; ION RECOMBINATION; PLATFORM;
D O I
10.1002/mp.14253
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: It has been recently shown that radiotherapy at ultrahigh dose rates (>40 Gy/s, FLASH) has a potential advantage in sparing healthy organs compared to that at conventional dose rates. The purpose of this work is to show the feasibility of proton FLASH irradiation using a gantry-mounted synchrocyclotron as a first step toward implementing an experimental setup for preclinical studies. Methods: A clinical Mevion HYPERSCAN(R)synchrocyclotron was modified to deliver ultrahigh dose rates. Pulse widths of protons with 230 MeV energy were manipulated from 1 to 20 mu s to deliver in conventional and ultrahigh dose rate. A boron carbide absorber was placed in the beam for range modulation. A Faraday cup was used to determine the number of protons per pulse at various dose rates. Dose rate was determined by the dose measured with a plane-parallel ionization chamber with respect to the actual delivery time. The integral depth dose (IDD) was measured with a Bragg ionization chamber. Monte Carlo simulation was performed in TOPAS as the secondary check for the measurements. Results: Maximum protons charge per pulse, measured with the Faraday cup, was 54.6 pC at 20 mu s pulse width. The measured IDD agreed well with the Monte Carlo simulation. The average dose rate measured using the ionization chamber showed 101 Gy/s at the entrance and 216 Gy/s at the Bragg peak with a full width at half maximum field size of 1.2 cm. Conclusions: It is feasible to deliver protons at 100 and 200 Gy/s average dose rate at the plateau and the Bragg peak, respectively, in a small similar to 1 cm(2)field using a gantry-mounted synchrocyclotron.
引用
收藏
页码:4348 / 4355
页数:8
相关论文
共 35 条
  • [21] FLASH radiotherapy: Newsflash or flash in the pan?
    Maxim, Peter G.
    Keall, Paul
    Cai, Jing
    [J]. MEDICAL PHYSICS, 2019, 46 (10) : 4287 - 4290
  • [22] Long-term neurocognitive benefits of FLASH radiotherapy driven by reduced reactive oxygen species
    Montay-Gruel, Pierre
    Acharya, Munjal M.
    Petersson, Kristoffer
    Alikhani, Leila
    Yakkala, Chakradhar
    Allen, Barrett D.
    Ollivier, Jonathan
    Petit, Benoit
    Jorge, Patrik Goncalves
    Syage, Amber R.
    Nguyen, Thuan A.
    Baddour, Al Anoud D.
    Lu, Celine
    Singh, Paramvir
    Moeckli, Raphael
    Bochud, Francois
    Germond, Jean-Francois
    Froidevaux, Pascal
    Bailat, Claude
    Bourhis, Jean
    Vozenin, Marie-Catherine
    Limoli, Charles L.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2019, 116 (22) : 10943 - 10951
  • [23] X-rays can trigger the FLASH effect: Ultra-high dose-rate synchrotron light source prevents normal brain injury after whole brain irradiation in mice
    Montay-Gruel, Pierre
    Bouchet, Audrey
    Jaccard, Maud
    Patin, David
    Serduc, Raphael
    Aim, Warren
    Petersson, Kristoffer
    Petit, Benoit
    Bailat, Claude
    Bourhis, Jean
    Brauer-Krisch, Elke
    Vozenin, Marie-Catherine
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 129 (03) : 582 - 588
  • [24] Irradiation in a flash: Unique sparing of memory in mice after whole brain irradiation with dose rates above 100 Gy/s
    Montay-Gruel, Pierre
    Petersson, Kristoffer
    Jaccard, Maud
    Boivin, Gael
    Germond, Jean-Francois
    Petit, Benoit
    Doenlen, Raphael
    Favaudon, Vincent
    Bochud, Francois
    Bailat, Claude
    Bourhis, Jean
    Vozenin, Marie-Catherine
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 124 (03) : 365 - 369
  • [25] Moyers M. F., 2012, PRACTICAL IMPLEMENTA
  • [26] O'Neal III CD, 2014, US patent, Patent No. [14/184,990, 14184990]
  • [27] Experimental Set-up for FLASH Proton Irradiation of Small Animals Using a Clinical System
    Patriarca, Annalisa
    Fouillade, Charles
    Auger, Michel
    Martin, Frederic
    Pouzoulet, Frederic
    Nauraye, Catherine
    Heinrich, Sophie
    Favaudon, Vincent
    Meyroneinc, Samuel
    Dendale, Remi
    Mazal, Alejandro
    Poortmans, Philip
    Verrelle, Pierre
    De Marzi, Ludovic
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : 619 - 626
  • [28] TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
    Perl, J.
    Shin, J.
    Schuemann, J.
    Faddegon, B.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2012, 39 (11) : 6818 - 6837
  • [29] High dose-per-pulse electron beam dosimetry - A model to correct for the ion recombination in the Advanced Markus ionization chamber
    Petersson, Kristoffer
    Jaccard, Maud
    Germond, Jean-Francois
    Buchillier, Thierry
    Bochud, Francois
    Bourhis, Jean
    Vozenin, Marie-Catherine
    Bailat, Claude
    [J]. MEDICAL PHYSICS, 2017, 44 (03) : 1157 - 1167
  • [30] Ultra-High-Dose-Rate FLASH Irradiation May Spare Hypoxic Stem Cell Niches in Normal Tissues
    Pratx, Guillem
    Kapp, Daniel S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : 190 - 192