Human Core Temperature Prediction for Heat-Injury Prevention

被引:14
作者
Laxminarayan, Srinivas [1 ]
Buller, Mark J. [2 ,3 ]
Tharion, William J. [2 ,3 ]
Reifman, Jaques [1 ]
机构
[1] US Army Med Res & Mat Command, Dept Def Biotechnol, High Performance Comp Software Applicat Inst, Telemed & Adv Technol Res Ctr, Ft Detrick, MD 21702 USA
[2] US Army Res Inst Environm Med, Natick, MA 01760 USA
[3] Biophys & Biomed Modeling Div, Natick, MA 01760 USA
关键词
Autoregressive (AR) model; core temperature; hyperthermia; prediction interval (PI); sequential probability ratio test (SPRT); GLUCOSE-CONCENTRATION; EXERCISE; TIME;
D O I
10.1109/JBHI.2014.2332294
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Previously, our group developed autoregressive (AR) models to predict human core temperature and help prevent hyperthermia (temperature > 39 degrees C). However, the models often yielded delayed predictions, limiting their application as a real-time warning system. To mitigate this problem, here we combined AR-model point estimates with statistically derived prediction intervals (PIs) and assessed the performance of three new alert algorithms [AR model plus PI, median filter of AR model plus PI decisions, and an adaptation of the sequential probability ratio test (SPRT)]. Using field-study data from 22 soldiers, including five subjects who experienced hyperthermia, we assessed the alert algorithms for AR-model prediction windows from 15-30 min. Cross-validation simulations showed that, as the prediction windows increased, improvements in the algorithms' effective prediction horizons were offset by deteriorating accuracy, with a 20-min window providing a reasonable compromise. Model plus PI and SPRT yielded the largest effective prediction horizons (>= 18 min), but these were offset by other performance measures. If high sensitivity and a long effective prediction horizon are desired, model plus PI provides the best choice, assuming decision switches can be tolerated. In contrast, if a small number of decision switches are desired, SPRT provides the best compromise as an early warning system of impending heat illnesses.
引用
收藏
页码:883 / 891
页数:9
相关论文
共 24 条
[1]  
Armed Forces Health Surveillance Center (AFHSC), 2011, MSMR, V18, P6
[2]  
Bequette B Wayne, 2010, J Diabetes Sci Technol, V4, P404
[3]  
Brearley M, 2012, J MIL VETERANS HEALT, V20, P25
[4]   Estimation of human core temperature from sequential heart rate observations [J].
Buller, Mark J. ;
Tharion, William J. ;
Cheuvront, Samuel N. ;
Montain, Scott J. ;
Kenefick, Robert W. ;
Castellani, John ;
Latzka, William A. ;
Roberts, Warren S. ;
Richter, Mark ;
Jenkins, Odest Chadwicke ;
Hoyt, Reed W. .
PHYSIOLOGICAL MEASUREMENT, 2013, 34 (07) :781-798
[5]   The ingestible telemetric body core temperature sensor: a review of validity and exercise applications [J].
Byrne, Christopher ;
Lim, Chin Leong .
BRITISH JOURNAL OF SPORTS MEDICINE, 2007, 41 (03) :126-133
[6]  
Chatfield Chris., 2002, Time-series forecasting
[7]   Are Standard Diagnostic Test Characteristics Sufficient for the Assessment of Continual Patient Monitoring? [J].
Chen, Liangyou ;
Reisner, Andrew T. ;
Chen, Xiaoxiao ;
Gribok, Andrei ;
Reifman, Jaques .
MEDICAL DECISION MAKING, 2013, 33 (02) :225-234
[8]  
Efron B., 1993, An introduction to the bootstrap
[9]   The pathopysiology of heat stroke: an integrative view of the final common pathway [J].
Epstein, Y. ;
Roberts, W. O. .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2011, 21 (06) :742-748
[10]   Providing statistical measures of reliability for body core temperature predictions [J].
Gribok, Andrei V. ;
Buller, Mark J. ;
Hoyt, Reed W. ;
Reifman, Jaques .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :545-+