Real time localized corrosion monitoring in industrial cooling water systems

被引:1
|
作者
Yang, B [1 ]
机构
[1] ONDEO Nalco, Naperville, IL 60563 USA
来源
CORROSION REVIEWS | 2001年 / 19卷 / 3-4期
关键词
cooling water; corrosion monitoring; crevice corrosion; heat exchanger; localized corrosion; mild steel; on line measurement; pitting; service life; water reuse;
D O I
10.1515/CORRREV.2001.19.3-4.315
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Localized corrosion, such as pitting and crevice/underdeposit corrosion, is responsible for the majority of plant equipment corrosion failures. However, the assessment of localized corrosion in plant operating conditions is often overlooked, partly due to the fact that none of the techniques commonly used today can provide realistic and effective monitoring of localized corrosion. Research carried out has resulted in the development of the Localized Corrosion Monitor (LCM) as a solution to this problem. The LCM is based on a new and patented electrochemical method capable of in situ on-line determination of underdeposit corrosion rates. Experimental results have shown that the LCM technique can be used to determine the rate of propagation of localized corrosion in mild steel accurately and reliably. It is ideally suited to monitor the performance of corrosion inhibition programs in industrial systems. In this paper, the scientific principles behind the LCM will be described. The usefulness of the LCM will be demonstrated by the results obtained in two refinery cooling water system trials. The results demonstrate clearly that the LCM localized corrosion rate is far more sensitive to process variable changes than general corrosion rate and real time on-line localized corrosion monitoring is most effective for treatment optimization to minimize the damaging effects of process variations.
引用
收藏
页码:315 / 346
页数:32
相关论文
共 50 条
  • [31] Real time monitoring of corrosion of rebar in concrete
    He, Hong-Zhu
    Cui, Yu-Li
    Shi, Mei-Lun
    Gu, You-Yan
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2013, 16 (01): : 50 - 54
  • [32] Usefulness of real-time PCR as a complementary tool to the monitoring of Legionella spp. and Legionella pneumophila by culture in industrial cooling systems
    Touron-Bodilis, A.
    Pougnard, C.
    Frenkiel-Lebosse, H.
    Hallier-Soulier, S.
    JOURNAL OF APPLIED MICROBIOLOGY, 2011, 111 (02) : 499 - 510
  • [33] A study of natural compounds as corrosion inhibitors for industrial cooling systems
    Minhaj, A
    Saini, PA
    Quraishi, MA
    Farooqi, IH
    CORROSION PREVENTION & CONTROL, 1999, 46 (02): : 32 - +
  • [34] In situ corrosion control in industrial water systems
    Batista, JF
    Pereira, RFC
    Lopes, JM
    Carvalho, MFM
    Feio, MJ
    Reis, MAM
    BIODEGRADATION, 2000, 11 (06) : 441 - 448
  • [35] In situ corrosion control in industrial water systems
    J.F. Batista
    R.F.C. Pereira
    J.M. Lopes
    M.F.M. Carvalho
    M.J. Feio
    M.A.M. Reis
    Biodegradation, 2000, 11 : 441 - 448
  • [36] Non-chromate anodic corrosion inhibition with desired deposition control in industrial cooling water systems
    Rajan, KS
    Venkatnath, K
    CORROSION AND ITS CONTROLS, VOLS I AND II, 1998, : 627 - 633
  • [37] Monitoring microbial fouling and corrosion problems in industrial systems
    Jack, TR
    CORROSION REVIEWS, 1999, 17 (01) : 1 - 31
  • [38] Corrosion Inhibitors for Water–Glycol Based Cooling Systems
    N. Yu. Bashkirtseva
    O. Yu. Sladovskaya
    Yu. S. Ovchinnikova
    L. A Vazetdinova
    Sh. N. Yusupov
    Chemistry and Technology of Fuels and Oils, 2017, 52 : 751 - 755
  • [39] CORROSION RATE MEASUREMENTS IN REFINERY COOLING WATER SYSTEMS
    BACKENSTO, EB
    GUSTAFSO.VM
    MATERIALS PROTECTION, 1967, 6 (12): : 25 - +
  • [40] CORROSION OF COOLING SYSTEMS AND HOT AND COLD WATER PIPES
    不详
    KALTE UND KLIMATECHNIK, 1979, 32 (02): : 87 - 88