Determination of the safe penetration depth during all-inside meniscal repair of the posterior part of the lateral meniscus using the FasT-Fix suture repair system

被引:22
作者
Abouheif, Mohamed Mahmoud [1 ,2 ]
Shibuya, Hayatoshi [1 ]
Niimoto, Takuya [1 ]
Kongcharoensombat, Wirat [1 ]
Deie, Masataka [1 ]
Adachi, Nobuo [1 ]
Ochi, Mitsuo [1 ]
机构
[1] Hiroshima Univ, Dept Orthopaed Surg, Grad Sch Biomed Sci, Minami Ku, Hiroshima 7348551, Japan
[2] Univ Alexandria, Fac Med, El Hadra Univ Hosp, Dept Orthoped Surg & Traumatol, Alexandria, Egypt
关键词
Knee; Lateral meniscus; FasT-Fix; Meniscal repair; Safe penetration; BIOMECHANICAL EVALUATION; ROOT TEAR; DEVICES; KNEE; MENISCECTOMY;
D O I
10.1007/s00167-011-1489-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The objective of this study was to determine the safe penetration depth of the FasT-Fix meniscal suture repair system during all-inside repair of the posterior part of the lateral meniscus. Methods Thirty-one knees from 17 embalmed and formalin-fixed cadavers (11 women, 6 men) were used. In each case, the circumference of the cadaver knee was measured before dissection. After dissection, 41 Fast-Fix meniscal repair devices were used in different predetermined penetration depths ranging from 8 to 16 mm. In this study, non-involvement of the popliteal neurovascular bundle, common peroneal nerve or the inferior lateral genicular vessels by either needle penetration or affixment by the suture bar anchors was considered to be a safe trial. Results Out of the 41 FasT-Fix devices used in this study, only one device bent during introduction and was excluded from the study. For the remaining 40 trials, 27 of them were considered safe, while 13 trials were considered unsafe. The ratio of the average penetration depth to the average circumference of the cadaver knee was found to be >0.05 for the unsafe penetrations, and this was statistically significant P < 0.05. Additionally, for the first point, which is more central, there was a trend for the straight needles through the direct lateral approach to be less safe, and this was found to be statistically significant P < 0.05. Conclusions Correlating the needle-penetration depth to the measured circumference of the cadaver knee may be an important clinical predictor of safety whereby a ratio of less than 0.05 might be useful as a guide to determine the safe penetration depth of the FasT-Fix suture repair needle during repair of the posterior horn lateral meniscus. Also, it is better to avoid using straight needles through the direct lateral approach during repair of the more central portion of the posterior horn lateral meniscus.
引用
收藏
页码:1868 / 1875
页数:8
相关论文
共 34 条
  • [1] Arthroscopic all inside repair of the lateral meniscus root tear
    Ahn, Jin Hwan
    Lee, Yong Seuk
    Chang, Jae-Young
    Chang, Moon Jong
    Eun, Sang Soo
    Kim, Sang Min
    [J]. KNEE, 2009, 16 (01) : 77 - 80
  • [2] Mechanical comparison of meniscal repair devices with mattress suture devices in vitro
    Aros, Brian C.
    Pedroza, Angela
    Vasileff, William K.
    Litsky, Alan S.
    Flanigan, David C.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (11) : 1594 - 1598
  • [3] MENISCAL TEARS - THE EFFECT OF MENISCECTOMY AND OF REPAIR ON INTRAARTICULAR CONTACT AREAS AND STRESS IN THE HUMAN KNEE - A PRELIMINARY-REPORT
    BARATZ, ME
    FU, FH
    MENGATO, R
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1986, 14 (04) : 270 - 275
  • [4] Load to failure testing of new meniscal repair devices
    Barber, FA
    Herbert, MA
    Richards, DP
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (01) : 45 - 50
  • [5] Meniscal repair devices
    Barber, FA
    Herbert, MA
    [J]. ARTHROSCOPY, 2000, 16 (06): : 613 - 618
  • [6] Barrett G R, 1997, Am J Knee Surg, V10, P2
  • [7] Preliminary results of the T-fix endoscopic meniscus repair technique in an anterior cruciate ligament reconstruction population
    Barrett, GR
    Treacy, SH
    Ruff, CG
    [J]. ARTHROSCOPY, 1997, 13 (02): : 218 - 223
  • [8] Biomechanical comparison of the FasT-Fix meniscal repair suture system with vertical mattress sutures and meniscus arrows
    Borden, P
    Nyland, J
    Caborn, DNM
    Pienkowski, D
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (03) : 374 - 378
  • [9] Lateral meniscus root tear and meniscus extrusion with anterior cruciate ligament tear
    Brody, JM
    Lin, HM
    Hulstyn, MJ
    Tung, GA
    [J]. RADIOLOGY, 2006, 239 (03) : 805 - 810
  • [10] Biomechanical evaluation of meniscal repair systems - A comparison of the Meniscal Viper Repair System, the vertical mattress FasT-Fix device, and vertical mattress ethibond sutures
    Chang, HC
    Nyland, J
    Caborn, DNM
    Burden, R
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (12) : 1846 - 1852