Polymeric Insulator Conditions Estimation by Using Leakage Current Characteristics Based on Simulation and Experimental Investigation

被引:13
作者
Salem, Ali Ahmed [1 ]
Lau, Kwan Yiew [1 ]
Abdul-Malek, Zulkurnain [1 ]
Mohammed, Nabil [2 ]
Al-Shaalan, Abdullah M. [3 ]
Al-Shamma'a, Abdullrahman A. [3 ]
Farh, Hassan M. H. [4 ]
机构
[1] Univ Teknol Malaysia, Sch Elect Engn, Inst High Voltage & High Current, Johor Baharu 81310, Malaysia
[2] Monash Univ, Dept Elect & Comp Syst Engn, Wellington Rd, Clayton, Vic 3800, Australia
[3] King Saud Univ, Coll Engn, Elect Engn Dept, Riyadh 11421, Saudi Arabia
[4] Hong Kong Polytech Univ, Fac Construct & Environm, Dept Bldg & Real Estate, Kowloon, Hong Kong 999077, Peoples R China
关键词
polymer insulator; prediction; pollution; leakage current indices; CONTAMINATION LEVEL; FLASHOVER PROCESS; CURRENT INDEX; POLLUTION; PERFORMANCE;
D O I
10.3390/polym14040737
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The current work contributes an estimate of the time-frequency characteristics of a leakage current in assessing the health condition of a polluted polymeric insulator. A 33 kV polymer insulator string was subjected to a series of laboratory tests under a range of environmental conditions, including pollution, wetting rate (WR), non-soluble deposit density (NSDD), and non-uniform distribution pollution (F-T/B). The temporal and frequency features of the leakage current were then extracted and used as assessment indicators for insulator conditions based on laboratory test findings. Two indices were generated from the leakage current waveform in the time domain: the curve slope index (F-1), which is determined by measuring the inclination of the curve between two successive time peaks of the leakage current, and the crest factor indicator (F-2). The frequency domain of the leakage current signal was used to calculate the other two indices. These are the odd harmonic indicators derived from the odd frequency harmonics of the leakage current up to the 9th component (F-3) and the 5th to 3rd harmonics ratio (F-4). The findings showed that the suggested indicators were capable of evaluating insulator conditions. Finally, the confusion matrix for the experimental and prediction results obtained with the proposed indices was used to assess which indicator performed the best. Therefore, the analysis suggests an alternative and effective method for estimating the health condition of a polluted insulator through leakage current characteristics obtained in the time and frequency domains.
引用
收藏
页数:17
相关论文
共 36 条
[1]  
Al-Ameri, 2019, INT J POWER ELECT DR, DOI [10.11591/ijpeds.v10.i2.pp602-610, DOI 10.11591/IJPEDS.V10.I2.PP602-610]
[2]   Forecasting Flashover Parameters of Polymeric Insulators under Contaminated Conditions Using the Machine Learning Technique [J].
Arshad ;
Ahmad, Jawad ;
Tahir, Ahsen ;
Stewart, Brian G. ;
Nekahi, Azam .
ENERGIES, 2020, 13 (15)
[3]   Using the Method of Harmonic Distortion Analysis in Partial Discharge Assessment in Mineral Oil in a Non-Uniform Electric Field [J].
Aydogan, Alper ;
Atalar, Fatih ;
Ersoy Yilmaz, Aysel ;
Rozga, Pawel .
ENERGIES, 2020, 13 (18)
[4]   Insulator Contamination Forecasting Based on Fractal Analysis of Leakage Current [J].
Chen, Weigen ;
Wang, Wanping ;
Xia, Qing ;
Luo, Bing ;
Li, Licheng .
ENERGIES, 2012, 5 (07) :2594-2607
[5]   Damage Evaluation of Porcelain Insulators with 154 kV Transmission Lines by Various Support Vector Machine (SVM) and Ensemble Methods Using Frequency Response Data [J].
Choi, In Hyuk ;
Koo, Ja Bin ;
Woo, Jung Wook ;
Son, Ju Am ;
Bae, Do Yeon ;
Yoon, Young Geun ;
Oh, Tae Keun .
APPLIED SCIENCES-BASEL, 2020, 10 (01)
[6]   An Evaluation of Alternative Techniques for Monitoring Insulator Pollution [J].
de Barros Bezerra, Jose Mauricio ;
Nogueira Lima, Antonio Marcus ;
Deep, Gurdip Singh ;
da Costa, Edson Guedes .
IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) :1773-1780
[7]   Flashover Process and Frequency Analysis of the Leakage Current on Insulator Model under non-Uniform Pollution Conditions [J].
Douar, M. A. ;
Mekhaldi, A. ;
Bouzidi, M. C. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (04) :1284-1297
[8]   Dynamic modeling of flashover of polymer insulators under polluted conditions based on HGA-PSO algorithm [J].
Fahimi, Navid ;
Sezavar, Hamid Reza ;
Akmal, Amir Abbas Shayegani .
ELECTRIC POWER SYSTEMS RESEARCH, 2022, 205
[9]  
Faramarzi Palangar M, 2016, IEEE T DIELECTR ELEC, V23, P3
[10]   A review of methods for the assessment of prediction errors in conservation presence/absence models [J].
Fielding, AH ;
Bell, JF .
ENVIRONMENTAL CONSERVATION, 1997, 24 (01) :38-49