A comparative clinical and functional assessment of cortical button versus suture anchor in distal biceps brachii tendon repair

被引:16
作者
Reichert, Pawel [1 ]
Krolikowska, Aleksandra [2 ]
Kentel, Maciej [3 ]
Witkowski, Jaroslaw [1 ]
Gnus, Jan [1 ]
Satora, Wojciech [4 ]
Czamara, Andrzej [2 ]
机构
[1] Wroclaw Med Univ, Div Sports Med, Bartla 5, PL-50556 Wroclaw, Poland
[2] Coll Physiotherapy Wroclaw, Dept Physiotherapy, Wroclaw, Poland
[3] eMKaMED Med Ctr, Wroclaw, Poland
[4] St Lukes Hosp, Dept Trauma & Orthoped Surg, Bielsko Biala, Poland
关键词
RUPTURES; RELIABILITY; ENDOBUTTON; FIXATION; VALIDITY; STRENGTH;
D O I
10.1016/j.jos.2018.08.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The studies comparing the fixation methods being used for the ruptured distal biceps brachii tendon reinsertion show similar outcomes of cortical button and suture anchors usage, however, longer follow-up studies remain necessary. The goal of this study was to compare the clinical and functional three-year outcomes of the cortical button in contrast to the suture anchor fixation. Methods: A retrospective cohort study comprised of 28 males on average 3 years after surgical reinsertion of the distal biceps brachii tendon with the use of a cortical button (Group I, n = 11) or a suture anchor (Group II, n = 17). The outcomes assessed were range of elbow joint and forearm motion (ROM), arm circumferences, visual analogue scale (VAS), Mayo Elbow Performance Index (MEPI), Quick Disability of the Arm, Shoulder, and Hand (Quick DASH) and forearm flexor and supinator muscle torques measured under isometric and isokinetic conditions. Results: The comparison between the two studied groups revealed no statistically significant differences in ROM (p = 0.24-1.00), circumferences (p = 0.15-0.50), VAS (p = 0.71), MEPI (p = 0.23), Quick DASH (p = 0.61) or in the obtained muscle torque values (p = 0.07-1.00). However, differences in supination ROM between the surgical and non-surgical side were found in both groups (p = 0.01-0.02), and differences in pronation (p = 0.02) were found in Group II. The muscle torque values obtained in the surgical, dominant limb were lower than those in the nonsurgical, nondominant limb. Conclusion: The comprehensive comparison of three-year outcomes of cortical button versus suture anchor fixations did not favour one fixation method over the other, and the results justify the clinical usage of both methods. (C) 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
[41]   Single Versus Double-Incision Technique for the Repair of Acute Distal Biceps Tendon Ruptures A Randomized Clinical Trial [J].
Grewal, Ruby ;
Athwal, George S. ;
MacDermid, Joy C. ;
Faber, Kenneth J. ;
Drosdowech, Darren S. ;
El-Hawary, Ron ;
King, Graham J. W. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (13) :1166-1174
[42]   Biomechanical Analysis of Patellar Tendon Repair With Knotless Suture Anchor Tape Versus Transosseous Suture [J].
Massey, Patrick A. ;
Myers, Mitchell ;
McClary, Kaylan ;
Brown, Jimmy ;
Barton, R. Shane ;
Solitro, Giovanni F. .
ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (10)
[43]   Retrospective Study of the Distal Biceps Tendon Repair Using "All-suture" Soft Anchors [J].
Metikalc, Sreenivasulu ;
Saleh, Zena ;
Bader, Dov A. ;
Sebastianelli, Wayne J. ;
Sherbondy, Paul S. .
TECHNIQUES IN ORTHOPAEDICS, 2022, 37 (03) :142-148
[44]   Suture-Only Repair Versus Suture AnchorAugmented Repair for Achilles Tendon Ruptures With a Short Distal Stump A Biomechanical Comparison [J].
Boin, Michael A. ;
Dorweiler, Matthew A. ;
McMellen, Christopher J. ;
Gould, Gregory C. ;
Laughlin, Richard T. .
ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2017, 5 (01)
[45]   The Effect of Drill Trajectory on Proximity to the Posterior Interosseous Nerve During Cortical Button Distal Biceps Repair [J].
Lo, Eddie Y. ;
Li, Chin-Shang ;
Van den Bogaerde, James M. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (08) :1048-1054
[46]   Prevalence and clinical implications of heterotopic ossification after distal biceps tendon repair [J].
Geuskens, W. ;
Caekebeke, P. ;
Van Riet, R. .
ACTA ORTHOPAEDICA BELGICA, 2023, 89 (04) :695-700
[47]   Biomechanical Evaluation of Suture Anchor versus Transosseous Tunnel Patellar Tendon Repair Techniques [J].
Sherman, Seth L. ;
Black, Brandee ;
Mooberry, Matthew A. ;
Freeman, Katie L. ;
Gulbrandsen, Trevor R. ;
Milles, Jeffrey L. ;
Evans, Laura ;
Flood, David ;
Pfeiffer, Ferris .
JOURNAL OF KNEE SURGERY, 2019, 32 (08) :825-831
[48]   Two Intramedullary and 1 Extramedullary Cortical Button, With or Without Interference Screw, Show Biomechanical Properties Superior to Native Tendon in Repair of the Distal Biceps Tendon: A Systematic Review and Network Meta-analysis of Biomechanical Performance [J].
Forlenza, Enrico M. ;
Lavoie-Gagne, Ophelie ;
Parvaresh, Kevin C. ;
Berlinberg, Elyse J. ;
Agarwalla, Avinesh ;
Forsythe, Brian .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2023, 39 (02) :390-401
[49]   Transosseous Repair With Nice Knot Augmentation Versus Knotless Suture Anchor Repair With Suture Tape for Quadriceps Tendon Rupturer A Cadaveric Study [J].
Duell, Bryan ;
Long, Mitchell K. ;
Divella, Michael ;
Fogel, Joshua ;
Ruotolo, Charles .
ORTHOPEDICS, 2023, 46 (03) :135-140
[50]   Distal biceps brachii tendon repair: a systematic review of patient outcome determination using modified Coleman methodology score criteria [J].
Nyland, John ;
Causey, Brandon ;
Wera, Jeff ;
Krupp, Ryan ;
Tate, David ;
Gupta, Amit .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (07) :2293-2297