A comparative clinical and functional assessment of cortical button versus suture anchor in distal biceps brachii tendon repair

被引:15
|
作者
Reichert, Pawel [1 ]
Krolikowska, Aleksandra [2 ]
Kentel, Maciej [3 ]
Witkowski, Jaroslaw [1 ]
Gnus, Jan [1 ]
Satora, Wojciech [4 ]
Czamara, Andrzej [2 ]
机构
[1] Wroclaw Med Univ, Div Sports Med, Bartla 5, PL-50556 Wroclaw, Poland
[2] Coll Physiotherapy Wroclaw, Dept Physiotherapy, Wroclaw, Poland
[3] eMKaMED Med Ctr, Wroclaw, Poland
[4] St Lukes Hosp, Dept Trauma & Orthoped Surg, Bielsko Biala, Poland
关键词
RUPTURES; RELIABILITY; ENDOBUTTON; FIXATION; VALIDITY; STRENGTH;
D O I
10.1016/j.jos.2018.08.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The studies comparing the fixation methods being used for the ruptured distal biceps brachii tendon reinsertion show similar outcomes of cortical button and suture anchors usage, however, longer follow-up studies remain necessary. The goal of this study was to compare the clinical and functional three-year outcomes of the cortical button in contrast to the suture anchor fixation. Methods: A retrospective cohort study comprised of 28 males on average 3 years after surgical reinsertion of the distal biceps brachii tendon with the use of a cortical button (Group I, n = 11) or a suture anchor (Group II, n = 17). The outcomes assessed were range of elbow joint and forearm motion (ROM), arm circumferences, visual analogue scale (VAS), Mayo Elbow Performance Index (MEPI), Quick Disability of the Arm, Shoulder, and Hand (Quick DASH) and forearm flexor and supinator muscle torques measured under isometric and isokinetic conditions. Results: The comparison between the two studied groups revealed no statistically significant differences in ROM (p = 0.24-1.00), circumferences (p = 0.15-0.50), VAS (p = 0.71), MEPI (p = 0.23), Quick DASH (p = 0.61) or in the obtained muscle torque values (p = 0.07-1.00). However, differences in supination ROM between the surgical and non-surgical side were found in both groups (p = 0.01-0.02), and differences in pronation (p = 0.02) were found in Group II. The muscle torque values obtained in the surgical, dominant limb were lower than those in the nonsurgical, nondominant limb. Conclusion: The comprehensive comparison of three-year outcomes of cortical button versus suture anchor fixations did not favour one fixation method over the other, and the results justify the clinical usage of both methods. (C) 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [1] Double intramedullary cortical button versus suture anchors for distal biceps tendon repair: a biomechanical comparison
    Siebenlist, Sebastian
    Buchholz, Arne
    Zapf, Julian
    Sandmann, Gunther H.
    Braun, Karl F.
    Martetschlaeger, Frank
    Hapfelmeier, Alexander
    Kraus, Tobias M.
    Lenich, Andreas
    Biberthaler, Peter
    Elser, Florian
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (03) : 926 - 933
  • [2] Retrospective Evaluation of Surgical Anatomical Repair of Distal Biceps Brachii Tendon Rupture Using Suture Anchor Fixation
    Witkowski, Jaroslaw
    Krolikowska, Aleksandra
    Czamara, Andrzej
    Reichert, Pawel
    MEDICAL SCIENCE MONITOR, 2017, 23 : 4961 - 4972
  • [3] Distal Biceps Tendon Repair: Suture Anchor Technique
    Colliton, Eileen
    Scheiderer, Bastian
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (02) : 114 - 116
  • [4] The Intramedullary Cortical Button Technique for Distal Biceps Tendon Repair
    Buchholz, Arne
    Siebenlist, Sebastian
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (02) : 126 - 129
  • [5] Bicortical suspensory button fixation yields greater ultimate load to failure over unicortical all-suture anchor fixation in distal biceps brachii tendon repair
    Garvin, Patrick M.
    Wellington, Ian J.
    Connors, John P.
    LeVasseur, Matthew R.
    Obopilwe, Elifho
    Hawthorne, Benjamin C.
    Trudeau, Maxwell
    Dorsey, Caitlin
    Mazzocca, Augustus D.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (11) : 2347 - 2357
  • [6] Biomechanical Comparison of Interference Screw and Cortical Button With Screw Hybrid Technique for Distal Biceps Brachii Tendon Repair
    Arianjam, Afshin
    Camisa, William
    Leasure, Jeremi M.
    Montgomery, William H.
    ORTHOPEDICS, 2013, 36 (11) : E1371 - E1377
  • [7] Suture anchor reinsertion of distal biceps rupture: Clinical results and radiological assessment of tendon healing
    Gallinet, D.
    Dietsch, E.
    Barbier-Brion, B.
    Lerais, J. -M.
    Obert, L.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (03) : 252 - 259
  • [8] Reconstruction of distal biceps tendon ruptures with a cortical button
    Kodde, Izaak F.
    van den Bekerom, Michel P. J.
    Eygendaal, Denise
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (03) : 919 - 925
  • [9] Treatment of primary total distal biceps tendon rupture using cortical button, transosseus fixation and suture anchor: A single center experience
    Lang, Nikolaus W.
    Bukaty, Adam
    Sturz, Geraldine D.
    Platzer, Patrick
    Joestl, Julian
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (06) : 859 - 863
  • [10] Biomechanical Comparison of Onlay Distal Biceps Tendon Repair: All-Suture Anchors Versus Titanium Suture Anchors
    Otto, Alexander
    Mehl, Julian
    Obopilwe, Elifho
    Cote, Mark
    Lacheta, Lucca
    Scheiderer, Bastian
    Imhoff, Andreas B.
    Mazzocca, Augustus D.
    Siebenlist, Sebastian
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (10): : 2478 - 2483