Convective heat transfer coefficients in a full-scale room with and without furniture

被引:31
作者
Wallentén, P [1 ]
机构
[1] Lund Inst Technol, Dept Bldg Sci, S-22100 Lund, Sweden
关键词
heat transfer; convective; coefficient; envelope; energy; model; in situ measurements; wall; window; temperature dependency; air; thermocouples;
D O I
10.1016/S0360-1323(00)00070-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The convective heat transfer coefficient at an outer ambient wall with a window exposed to natural climate was measured in a room with and without furniture. The method used was to estimate the heat flow from measured temperatures and solar radiation. The convective heat transfer was calculated as the difference between the heat flow through the building element and the calculated long-wave radiation. Even though the accuracy was at best +/- 15%, the effect of different heating and ventilation strategies could clearly be detected. Local coefficients may be more than 10 times the expected, due to ventilation or position of the radiator. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:743 / 751
页数:9
相关论文
共 50 条
[21]   Effect of the variability of heat and mass transfer coefficients on convective and convective-radiative drying of porous media [J].
Boukadida, N ;
Ben Nasrallah, S .
DRYING TECHNOLOGY, 2002, 20 (01) :67-91
[22]   Analysis on convective heat transfer coefficients of external surfaces for typical building arrays [J].
Zheng, Shu ;
Wang, Yi ;
Feng, Fan ;
Xue, Yu ;
Wang, Zhichao ;
Duanmu, Lin .
JOURNAL OF BUILDING ENGINEERING, 2022, 62
[23]   Convective Heat Transfer Coefficients in a Building-Integrated Photovoltaic/Thermal System [J].
Candanedo, Luis M. ;
Athienitis, Andreas ;
Park, Kwang-Wook .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (02)
[24]   The development of an accurate tool to determine convective heat transfer coefficients in real buildings [J].
Davies, M ;
Martin, C ;
Watson, M ;
Riain, CN .
ENERGY AND BUILDINGS, 2005, 37 (02) :141-145
[25]   On the heat transfer coefficients between heated/cooled radiant ceiling and room [J].
Cholewa, Tomasz ;
Anasiewicz, Rafal ;
Siuta-Olcha, Alicja ;
Skwarczynski, Mariusz A. .
APPLIED THERMAL ENGINEERING, 2017, 117 :76-84
[26]   Experimental and numerical investigation of the correlation between radiative and convective heat-transfer coefficients at the cooled wall of a real-sized room [J].
Acikgoz, Ozgen ;
Kincay, Olcay .
ENERGY AND BUILDINGS, 2015, 108 :257-266
[27]   The Changing and Distribution Laws of Oxygen Transfer Efficiency in the Full-Scale IFAS Process [J].
Liu, Xuyang ;
Bi, Xuejun ;
Huang, Qing ;
Wang, Xiaodong ;
Gu, Ruihuan ;
Zhou, Xiaolin .
WATER, 2021, 13 (14)
[28]   Convective heat transfer on leeward building walls in an urban environment: Measurements in an outdoor scale model [J].
Nottrott, A. ;
Onomura, S. ;
Inagaki, A. ;
Kanda, M. ;
Kleissl, J. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (15-16) :3128-3138
[29]   Full-scale measurements of convective coefficient on external surface of a low-rise building in sheltered conditions [J].
Liu, Y. ;
Harris, D. J. .
BUILDING AND ENVIRONMENT, 2007, 42 (07) :2718-2736
[30]   Experimental determination of structural damping of a full-scale building with and without tuned liquid dampers [J].
Tarpo, Marius ;
Georgakis, Christos ;
Brandt, Anders ;
Brincker, Rune .
STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (03)