Performance of corrosion inhibitors in reinforced concrete elements under electrical voltage

被引:12
|
作者
Lapiro, Igor [1 ]
Mezhov, Alexander [1 ,2 ]
Kovler, Konstantin [1 ]
机构
[1] Technion Israel Inst Technol, Natl Bldg Res Inst, Fac Civil & Environm Engn, Haifa, Israel
[2] Bundesanstalt Mat Forsch & Prufung BAM, Div Technol Construct Mat, Berlin, Germany
关键词
Steel corrosion; Reinforced concrete; Accelerated test; Corrosion inhibitor; Stray current; STEEL; BEHAVIOR; IRON;
D O I
10.1016/j.conbuildmat.2022.127656
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The current paper develops a novel accelerated corrosion test method based on Faraday's law to investigate the performance of different inhibitors in reinforced concrete elements under electrical voltage. Using the proposed method two commercially available and three lab-made inhibitors were tested. Lab-made inhibitors based on potassium fluorosilicate and amine carboxylate showed the best performance over others. Furthermore, it is found that under an electrical potential environment beyond 3.6 V, the higher the concrete strength, the more efficient is the corrosion inhibition. Based on experimental results, a novel model describing the corrosion evolution in reinforced concrete was proposed.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Corrosion inhibitors for high performance reinforced concrete structures
    Mulheron, M
    Nwaubani, SO
    ROLE OF ADMIXTURES IN HIGH PERFORMANCE CONCRETE, 1999, 5 : 183 - 198
  • [2] Modelling Strategies for Reinforced Concrete Elements under Corrosion Degradation
    Imperatore, Stefania
    MATERIALS, 2022, 15 (13)
  • [3] Experiences on corrosion inhibitors for reinforced concrete
    Bolzoni, F.
    Brenna, A.
    Fumagalli, G.
    Goidanich, S.
    Lazzari, L.
    Ormellese, M.
    Pedeferri, M. P.
    INTERNATIONAL JOURNAL OF CORROSION AND SCALE INHIBITION, 2014, 3 (04): : 254 - 278
  • [4] Chloride-induced corrosion in reinforced concrete and fiber reinforced concrete elements under tensile service loads
    Leporace-Guimil, Bruno
    Conforti, Antonio
    Zerbino, Raul
    Plizzari, Giovanni A.
    CEMENT & CONCRETE COMPOSITES, 2021, 124
  • [5] Corrosion damage of centrifuged reinforced concrete elements
    Pepenar, I.
    CONCRETE SOLUTIONS, 2012, : 101 - 104
  • [6] Flexural performance of reinforced concrete beams strengthened with fibre reinforced geopolymer concrete under accelerated corrosion
    Al-Majidi, Mohammed Haloob
    Lampropoulos, Andreas P.
    Cundy, Andrew B.
    Tsioulou, Ourania T.
    Alrekabi, Salam
    STRUCTURES, 2019, 19 : 394 - 410
  • [7] Sacrificial Elements for Corrosion Detection in Reinforced Concrete
    Abu-Yosef, Ali
    Pasupathy, Praveen
    Wood, Sharon L.
    Neikirk, Dean
    Wheat, Harovel
    ACI MATERIALS JOURNAL, 2022, 119 (02) : 43 - 51
  • [8] A new generation of corrosion inhibitors for reinforced concrete
    Mäder, U
    REPAIR AND MAINTENANCE OF CONCRETE AND REINFORCED CONCRETE STRUCTURES, 1997, : 71 - 80
  • [9] Evaluation of corrosion inhibitors for reinforced concrete structures
    Trevisol, Cesar Augusto
    Paes da Silva, Paulo Roberto
    da Silva Paula, Marcos Marques
    Pelisser, Fernando
    MATERIA-RIO DE JANEIRO, 2017, 22 (04):
  • [10] Research on Effects of Inhibitors on Anti-corrosion Performance of Reinforced Bar in the Concrete
    Song, Liubin
    Yang, Daowu
    Xiao, Zhongliang
    Zhang, Feng
    ADVANCED MATERIALS, PTS 1-4, 2011, 239-242 : 1195 - 1198