Detection of occult paroxysmal atrial fibrillation

被引:48
作者
Petrenas, Andrius [1 ]
Sornmo, Leif [2 ,3 ]
Lukosevicius, Arunas [1 ]
Marozas, Vaidotas [1 ]
机构
[1] Kaunas Univ Technol, Inst Biomed Engn, LT-44029 Kaunas, Lithuania
[2] Lund Univ, Dept Biomed Engn, Lund, Sweden
[3] Lund Univ, Ctr Integrat Electrocardiol, Lund, Sweden
关键词
Paroxysmal atrial fibrillation; Brief episodes; Detection; Echo state network; Fuzzy logic; AUTOMATIC DETECTION; ISCHEMIC-STROKE; SIGNALS; MODEL; RR;
D O I
10.1007/s11517-014-1234-y
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This work introduces a novel approach to the detection of brief episodes of paroxysmal atrial fibrillation (PAF). The proposed detector is based on four parameters which characterize RR interval irregularity, P-wave absence, f-wave presence, and noise level, of which the latter three are determined from a signal produced by an echo state network. The parameters are used for fuzzy logic classification where the decisions involve information on prevailing signal quality; no training is required. The performance is evaluated on a large set of test signals with brief episodes of PAF. The results show that episodes with as few as five beats can be reliably detected with an accuracy of 0.88, compared to 0.82 for a detector based on rhythm information only (the coefficient of sample entropy); this difference in accuracy increases when atrial premature beats are present. The results also show that the performance remains essentially unchanged at noise levels up to RMS. It is concluded that the combination of information on ventricular activity, atrial activity, and noise leads to substantial improvement when detecting brief episodes of PAF.
引用
收藏
页码:287 / 297
页数:11
相关论文
共 34 条
[1]   Improvements in atrial fibrillation detection for real-time monitoring [J].
Babaeizadeh, Saeed ;
Gregg, Richard E. ;
Helfenbein, Eric D. ;
Lindauer, James M. ;
Zhou, Sophia H. .
JOURNAL OF ELECTROCARDIOLOGY, 2009, 42 (06) :522-526
[2]   ECG Signal Quality During Arrhythmia and Its Application to False Alarm Reduction [J].
Behar, Joachim ;
Oster, Julien ;
Li, Qiao ;
Clifford, Gari D. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (06) :1660-1666
[3]  
Bousseljot R., 1995, BIOMED ENG-BIOMED TE, V40, P317, DOI [DOI 10.1016/J.SIGPRO.2007.11.014, 10.1515/bmte.1995.40.s1.317]
[4]   Spatiotemporal blind source separation approach to atrial activity estimation in atrial tachyarrhythmias [J].
Castells, F ;
Rieta, JJ ;
Millet, J ;
Zarzoso, V .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (02) :258-267
[5]   A Comprehensive Evaluation of Rhythm Monitoring Strategies for the Detection of Atrial Fibrillation Recurrence Insights From 647 Continuously Monitored Patients and Implications for Monitoring After Therapeutic Interventions [J].
Charitos, Efstratios I. ;
Stierle, Ulrich ;
Ziegler, Paul D. ;
Baldewig, Malte ;
Robinson, Derek R. ;
Sievers, Hans-Hinrich ;
Hanke, Thorsten .
CIRCULATION, 2012, 126 (07) :806-814
[6]   An Atrioventricular Node Model for Analysis of the Ventricular Response During Atrial Fibrillation [J].
Corino, Valentina D. A. ;
Sandberg, Frida ;
Mainardi, Luca T. ;
Sornmo, Leif .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (12) :3386-3395
[7]  
Couceiro R., 2008, 2008 19th International Conference on Pattern Recognition, P1
[8]   Automatic Real Time Detection of Atrial Fibrillation [J].
Dash, S. ;
Chon, K. H. ;
Lu, S. ;
Raeder, E. A. .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (09) :1701-1709
[9]  
de Carvalho P, 2012, ECG SIGNAL PROCESSING, CLASSIFICATION AND INTERPRETATION: A COMPREHENSIVE FRAMEWORK OF COMPUTATIONAL INTELLIGENCE, P99, DOI 10.1007/978-0-85729-868-3_5
[10]   PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220