Retinal adaptive optics imaging with a pyramid wavefront sensor

被引:13
作者
Brunner, Elisabeth [1 ]
Shatokhina, Julia [2 ]
Shirazi, Muhammad Faizan [1 ]
Drexler, Wolfgang [1 ]
Leitgeb, Rainer [1 ]
Pollreisz, Andreas [3 ]
Hitzenberger, Christoph K.
Ramlau, Ronny [1 ,2 ,4 ]
Pircher, Michael [1 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Johann Radon Inst Computat & Appl Math, Altenbergerstr 69, A-4040 Linz, Austria
[3] Med Univ Vienna, Dept Ophthalmol & Optometry, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[4] Johannes Kepler Univ Linz, Ind Math Inst, Altenbergerstr 69, A-4040 Linz, Austria
来源
BIOMEDICAL OPTICS EXPRESS | 2021年 / 12卷 / 10期
基金
奥地利科学基金会; 欧盟地平线“2020”;
关键词
PUPIL;
D O I
10.1364/BOE.438915
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The pyramid wavefront sensor (P-WFS) has replaced the Shack-Har tmann (SH-) WFS as the sensor of choice for high-performance adaptive optics (AO) systems in astronomy. Many advantages of the P-WFS, such as its adjustable pupil sampling and superior sensitivity, are potentially of great benefit for AO-supported imaging in ophthalmology as well. However, so far no high quality ophthalmic AO imaging was achieved using this novel sensor. Usually, a P-WFS requires modulation and high precision optics that lead to high complexity and costs of the sensor. These factors limit the competitiveness of the P-WFS with respect to other WFS devices for AO correction in visual science. Here, we present a cost-effective realization of AO correction with a non-modulated P-WFS based on standard components and apply this technique to human retinal in vivo imaging using optical coherence tomography (OCT). P-WFS based high quality AO imaging was successfully performed in 5 healthy subjects and smallest retinal cells such as central foveal cone photoreceptors are visualized. The robustness and versatility of the sensor is demonstrated in the model eye under various conditions and in vivo by high-resolution imaging of other structures in the retina using standard and extended fields of view. As a quality benchmark, the performance of conventional SH-WFS based AO was used and successfully met. This work may trigger a paradigm shift with respect to the wavefront sensor of choice for AO in ophthalmic imaging.
引用
收藏
页码:5969 / 5990
页数:22
相关论文
共 52 条
  • [41] WAVE-FRONT RECONSTRUCTION FROM DEFOCUSED IMAGES AND THE TESTING OF GROUND-BASED OPTICAL TELESCOPES
    RODDIER, C
    RODDIER, F
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (11): : 2277 - 2287
  • [42] Adaptive optics scanning laser ophthalmoscopy
    Roorda, A
    Romero-Borja, F
    Donnelly, WJ
    Queener, H
    Hebert, TJ
    Campbell, MCW
    [J]. OPTICS EXPRESS, 2002, 10 (09): : 405 - 412
  • [43] ROUSSET G, 1990, ASTRON ASTROPHYS, V230, pL29
  • [44] SHACK RV, 1971, J OPT SOC AM, V61, P656
  • [45] Review on methods for wavefront reconstruction from pyramid wavefront sensor data
    Shatokhina, Iuliia
    Hutterer, Victoria
    Ramlau, Ronny
    [J]. JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2020, 6 (01)
  • [46] Visualizing human photoreceptor and retinal pigment epithelium cell mosaics in a single volume scan over an extended field of view with adaptive optics optical coherence tomography
    Shirazi, Muhammad Faizan
    Brunner, Elisabeth
    Laslandes, Marie
    Pollreisz, Andreas
    Hitzenberger, Christoph K.
    Pircher, Michael
    [J]. BIOMEDICAL OPTICS EXPRESS, 2020, 11 (08) : 4520 - 4535
  • [47] Validation of a Clinical Aberrometer Using Pyramidal Wavefront Sensing
    Singh, Neeraj K.
    Jaskulski, Matt
    Ramasubramanian, Viswanathan
    Meyer, Dawn
    Reed, Olivia
    Rickert, Martin E.
    Bradley, Arthur
    Kollbaum, Pete S.
    [J]. OPTOMETRY AND VISION SCIENCE, 2019, 96 (10) : 733 - 744
  • [48] Adaptive optics for high-contrast imaging:: pyramid sensor versus spatially filtered Shack-Hartmann sensor
    Vérinaud, C
    Le Louarn, M
    Korkiakoski, V
    Carbillet, M
    [J]. MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2005, 357 (01) : L26 - L30
  • [49] On the nature of the measurements provided by a pyramid wave-front sensor
    Vérinaud, C
    [J]. OPTICS COMMUNICATIONS, 2004, 233 (1-3) : 27 - 38
  • [50] High-speed adaptive optics for imaging of the living human eye
    Yu, Yongxin
    Zhang, Tianjiao
    Meadway, Alexander
    Wang, Xiaolin
    Zhang, Yuhua
    [J]. OPTICS EXPRESS, 2015, 23 (18): : 23035 - 23052