Comparison of repeat videokeratography: Repeatability and accuracy

被引:33
作者
Jeandervin, M [1 ]
Barr, J [1 ]
机构
[1] Ohio State Univ, Coll Optometry, Columbus, OH 43210 USA
关键词
videokeratography; corneal topography; repeatability; accuracy; corneal curvature;
D O I
10.1097/00006324-199809000-00021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. We compared the repeatability and accuracy of four commercially available videokeratography instruments and a manual keratometer. Methods. Ten optometry students and two university employees who had no history of rigid contact lens wear and no soft contact lens wear within 6 months of the study were measured. Two independent measurements were taken on the right eyes only using the Alcon EyeMap EH-290 topography system (both manual and automatic focus), the EyeSys System 2000 corneal topography system, the Humphrey Mastervue topography system, the Humphrey Atlas topography system, and a Marco manual keratometer. A three-factor repeated measures analysis of variance with all factors repeated was performed using SAS and BMDP statistical software. Separate analyses were conducted for paracentral and peripheral data. To test accuracy, measurements were taken with the Alcon EyeMap automatic focus system, the EyeSys System 2000, the Humphrey Atlas system, and the Humphrey Mastervue system using four calibration spheres. Results. There were no statistically significant differences in the repeatability of the instruments. The EyeSys corneal topography system had the most narrow 95% limits of agreement around the mean difference. The two Humphrey instruments performed similarly to the EyeSys. Although the Alcon EyeMap EH-290 had the widest 95% limits of agreement around the mean difference, it showed better repeatability when the manual focus was used compared with the automatic focus. The instruments varied in their level of accuracy, but the highest percentage of data points within +/-0.37 D of the known values of the calibration spheres was found with the Humphrey Atlas. Conclusions. Although there were no statistically significant differences in repeatability, the EyeSys System 2000 had the highest repeatability, which may have clinical relevance. The accuracy measured in this study varied tremendously; however, the Humphrey Atlas was found to be the most accurate of the instruments tested.
引用
收藏
页码:663 / 669
页数:7
相关论文
共 15 条
[1]  
[Anonymous], INT CONTACT LENS CLI
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
DAVIS L J, 1991, CLAO Journal, V17, P191
[4]   EYESYS CORNEAL TOPOGRAPHY MEASUREMENT APPLIED TO CALIBRATED ELLIPSOIDAL CONVEX SURFACES [J].
DOUTHWAITE, WA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (09) :797-801
[5]  
Hamburg Tracey, 1997, Investigative Ophthalmology and Visual Science, V38, pS851
[6]   ACCURACY AND PRECISION OF KERATOMETRY, PHOTOKERATOSCOPY, AND CORNEAL MODELING ON CALIBRATED STEEL BALLS [J].
HANNUSH, SB ;
CRAWFORD, SL ;
WARING, GO ;
GEMMILL, MC ;
LYNN, MJ ;
NIZAM, A .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (08) :1235-1239
[7]   REPRODUCIBILITY OF NORMAL CORNEAL POWER MEASUREMENTS WITH A KERATOMETER, PHOTOKERATOSCOPE, AND VIDEO IMAGING-SYSTEM [J].
HANNUSH, SB ;
CRAWFORD, SL ;
WARING, GO ;
GEMMILL, MC ;
LYNN, MJ ;
NIZAM, A .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (04) :539-544
[8]   RELIABILITY AND VALIDITY OF VIDEOKERATOSCOPIC MEASUREMENTS [J].
HEATH, GG ;
GERSTMAN, DR ;
WHEELER, WH ;
SONI, PS ;
HORNER, DG .
OPTOMETRY AND VISION SCIENCE, 1991, 68 (12) :946-949
[9]  
Koch D D, 1989, Refract Corneal Surg, V5, P424
[10]   COMPARISON OF THE ACCURACY AND REPRODUCIBILITY OF THE KERATOMETER AND THE EYESYS CORNEAL ANALYSIS SYSTEM MODEL-I [J].
KOCH, DD ;
WAKIL, JS ;
SAMUELSON, SW ;
HAFT, EA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (04) :342-347