Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position - A radiographic analysis

被引:78
|
作者
Maestro, A [1 ]
Harwin, SF [1 ]
Sandovaal, MG [1 ]
Vaquero, DH [1 ]
Murcia, A [1 ]
机构
[1] Cabuenes Hosp, Dept Orthopaed Surg, Gijon, Spain
关键词
total knee arthroplasty; alignment; intramedullary guides; extramedullary guides; radiographic analysis;
D O I
10.1016/S0883-5403(98)90055-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A prospective study of 116 consecutive Kinemax cemented posterior cruciate ligament-retaining total knee arthroplasties was carried out. Similar surgical technique was used with a single variable: 61 were implanted using intramedullary guides on the tibia and 55 were implanted using extramedullary guides on the tibia. A radiographic study was performed after at least 1 year of follow-up to evaluate postoperative component position and compare the difference in the accuracy of positioning of the femoral and tibial components. Radiographic analysis showed that satisfactory position was achieved using both types of instrumentation. No statistically significant difference was observed in either the coronal or sagittal plane of the femoral component and the sagittal plane positioning of the tibial component. However, the coronal plane positioning of the tibial component revealed a statistically significant difference (P < .01), with intramedullary guides being superior to extramedullary guides. Also observed, was that using either technique, patients with less accurate postoperative positioning tended to be obese, with wide intramedullary canals. Patients with significant extraarticular deformities, marked bowing, and those with prior surgery or fractures may not be suitable for intramedullary guides, and they may require the use of extramedullary guides and intraoperative radiographic control. The ideal indication for the use of intramedullary instrumentation is in the patient who is not obese, with no extraarticular deformity, and with a well-defined, but not excessively wide, tibial medullary canal. Since tibial component malalignment in general, and coronal plane malalignment in particular, may adversely affect the long-term survival of total knee arthroplasties, the use of intramedullary alignment instrumentation is recommended when possible.
引用
收藏
页码:552 / 558
页数:7
相关论文
共 50 条
  • [31] Leg alignment and tibial slope after minimal invasive total knee arthroplasty: A prospective, randomized radiological study of intramedullary versus extramedullary tibial instrumentation
    de Kroon, Karin E.
    Houterman, Saskia
    Janssen, Rob P. A.
    KNEE, 2012, 19 (04) : 270 - 274
  • [32] Alignment in knee flexion position during navigation-assisted total knee arthroplasty
    Jae-Hyuk Yang
    Anshul Dahuja
    Jin-Kak Kim
    Se-Hyeok Yun
    Jung-Ro Yoon
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 2422 - 2429
  • [33] Alignment in knee flexion position during navigation-assisted total knee arthroplasty
    Yang, Jae-Hyuk
    Dahuja, Anshul
    Kim, Jin-Kak
    Yun, Se-Hyeok
    Yoon, Jung-Ro
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2422 - 2429
  • [34] Radiographic outcome of limb-based versus knee-based patient specific guides in total knee arthroplasty
    Crane, Catherine
    Marimuthu, Kanniraj
    Chen, Darren B.
    Harris, Ian A.
    Wheatley, Emma
    MacDessi, Samuel J.
    KNEE, 2014, 21 (06) : 1244 - 1249
  • [35] Coronal and Sagittal Component Position in Contemporary Total Knee Arthroplasty: Targeting Native Alignment Optimizes Clinical Outcomes
    Farooq, Hassan
    Deckard, Evan R.
    Carlson, Justin
    Ghattas, Nathan
    Meneghini, R. Michael
    JOURNAL OF ARTHROPLASTY, 2023, 38 (07) : S245 - S251
  • [36] Evaluation of the rotational alignment of the tibial component in total knee arthroplasty: position prioritizing maximum coverage
    Hirakawa M.
    Miyazaki M.
    Ikeda S.
    Matsumoto Y.
    Kondo M.
    Tsumura H.
    European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (1) : 119 - 124
  • [37] Landmarks for optimizing component position in total knee arthroplasty
    Hepinstall, Matthew S.
    Ranawat, Amar S.
    CURRENT ORTHOPAEDIC PRACTICE, 2008, 19 (02): : 147 - 154
  • [38] Surgeon variability in total knee arthroplasty component alignment: a Monte Carlo analysis
    Gatti, Christopher J.
    Hallstrom, Brian R.
    Hughes, Richard E.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (15) : 1738 - 1750
  • [39] The dorsal pedis artery as a new distal landmark for extramedullary tibial alignment in total knee arthroplasty
    Natsuki Sugimura
    Masahiko Ikeuchi
    Masashi Izumi
    Koji Aso
    Takahiro Ushida
    Toshikazu Tani
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 2618 - 2622
  • [40] Radiographic assessment of knee-ankle alignment after total knee arthroplasty for varus and valgus knee osteoarthritis
    Gao, Fuqiang
    Ma, Jinhui
    Sun, Wei
    Guo, Wanshou
    Li, Zirong
    Wang, Weiguo
    KNEE, 2017, 24 (01) : 107 - 115