Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position - A radiographic analysis

被引:78
|
作者
Maestro, A [1 ]
Harwin, SF [1 ]
Sandovaal, MG [1 ]
Vaquero, DH [1 ]
Murcia, A [1 ]
机构
[1] Cabuenes Hosp, Dept Orthopaed Surg, Gijon, Spain
关键词
total knee arthroplasty; alignment; intramedullary guides; extramedullary guides; radiographic analysis;
D O I
10.1016/S0883-5403(98)90055-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A prospective study of 116 consecutive Kinemax cemented posterior cruciate ligament-retaining total knee arthroplasties was carried out. Similar surgical technique was used with a single variable: 61 were implanted using intramedullary guides on the tibia and 55 were implanted using extramedullary guides on the tibia. A radiographic study was performed after at least 1 year of follow-up to evaluate postoperative component position and compare the difference in the accuracy of positioning of the femoral and tibial components. Radiographic analysis showed that satisfactory position was achieved using both types of instrumentation. No statistically significant difference was observed in either the coronal or sagittal plane of the femoral component and the sagittal plane positioning of the tibial component. However, the coronal plane positioning of the tibial component revealed a statistically significant difference (P < .01), with intramedullary guides being superior to extramedullary guides. Also observed, was that using either technique, patients with less accurate postoperative positioning tended to be obese, with wide intramedullary canals. Patients with significant extraarticular deformities, marked bowing, and those with prior surgery or fractures may not be suitable for intramedullary guides, and they may require the use of extramedullary guides and intraoperative radiographic control. The ideal indication for the use of intramedullary instrumentation is in the patient who is not obese, with no extraarticular deformity, and with a well-defined, but not excessively wide, tibial medullary canal. Since tibial component malalignment in general, and coronal plane malalignment in particular, may adversely affect the long-term survival of total knee arthroplasties, the use of intramedullary alignment instrumentation is recommended when possible.
引用
收藏
页码:552 / 558
页数:7
相关论文
共 50 条
  • [21] Angle Accuracy of Intramedullary Bone Resection Guides for Total Knee Arthroplasty
    Kane, Matthew C.
    Cates, Harold E.
    Chang, Iou-Ren
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [22] Is the femoral intramedullary alignment already actual in total knee arthroplasty?
    Tecame, Andrea
    Gambineri, Andrea
    Za, Pierangelo
    Adravanti, Paolo
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2023, 10 (01)
  • [23] Mechanical versus kinematic alignment for total knee arthroplasty: a meta-analysis
    Migliorini, Filippo
    Maffulli, Nicola
    Pilone, Marco
    Schafer, Luise
    Ullmann, David
    Huber, Thorsten
    Rath, Bjoern
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [24] Potential errors in axial alignment using intramedullary instrumentation for total knee arthroplasty
    Nuño-Siebrecht, N
    Tanzer, M
    Bobyn, JD
    JOURNAL OF ARTHROPLASTY, 2000, 15 (02) : 228 - 230
  • [25] Extramedullary Guide Alignment Is not Affected by Obesity in Primary Total Knee Arthroplasty
    Compton, Jocelyn
    Owens, Jessell
    Otero, Jesse
    Noiseux, Nicolas
    Brown, Timothy
    JOURNAL OF KNEE SURGERY, 2021, 34 (10) : 1076 - 1079
  • [26] Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty
    Ma, B
    Long, W
    Rudan, JF
    Ellis, RE
    JOURNAL OF ARTHROPLASTY, 2006, 21 (02) : 271 - 278
  • [27] Improving tibial component alignment in total knee arthroplasty
    G. Cinotti
    P. Sessa
    A. D’Arino
    F. R. Ripani
    G. Giannicola
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 3563 - 3570
  • [28] Effect of Obesity on Component Alignment in Total Knee Arthroplasty
    Ojard, Connor
    Habashy, Alexander
    Meyer, Mark
    Chimento, George
    Ochsner, John L.
    OCHSNER JOURNAL, 2018, 18 (03) : 226 - 229
  • [29] Rotational alignment of the tibial component in total knee arthroplasty
    Indelli, Pier Francesco
    Graceffa, Angelo
    Marcucci, Massimiliano
    Baldini, Andrea
    ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (01)
  • [30] Improving tibial component alignment in total knee arthroplasty
    Cinotti, G.
    Sessa, P.
    D'Arino, A.
    Ripani, F. R.
    Giannicola, G.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (12) : 3563 - 3570