共 33 条
Visual Performance and Quality of Life after Femtosecond Laser-Assisted Cataract Surgery with Trifocal IOLs Implantation
被引:6
作者:
Gallenga, Carla Enrica
[1
]
D'Aloisio, Rossella
[2
]
D'Ugo, Erminia
[2
]
Vecchiarino, Luca
[2
]
Agnifili, Luca
[2
]
Simonelli, Maria Beatrice
[2
]
Di Nicola, Marta
[3
]
Toto, Lisa
[2
]
Perri, Paolo
[4
]
机构:
[1] Univ Ferrara, Dept Med Sci, I-44121 Ferrara, Italy
[2] Univ G dAnnunzio, Dept Med & Aging Sci, Ophthalmol Clin, I-66100 Chieti, Italy
[3] Univ G dAnnunzio, Dept Expt & Clin Sci, Lab Biostat, I-66100 Chieti, Italy
[4] Univ Ferrara, Dept Neurosci & Rehabil, Sect Ophthalmol, I-44121 Ferrara, Italy
关键词:
trifocal IOLs;
femtosecond laser-assisted cataract surgery;
quality of life;
MULTIFOCAL INTRAOCULAR LENSES;
BILATERAL IMPLANTATION;
CONTRAST SENSITIVITY;
REFRACTIVE OUTCOMES;
PRESBYOPIA;
DISTANCE;
EYES;
D O I:
10.3390/jcm10143038
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Purpose: To assess visual performance and quality of life after implantation of diffractive trifocal IOLs with enhanced depth of focus (Acriva Reviol Tri-ED) compared to monofocal IOLs. Setting: Ophthalmology Clinic, Department of Medicine and Science of Ageing, University "G. d'Annunzio" Chieti-Pescara, Italy. Design: Prospective clinical study. Methods: This study comprised 36 eyes of 18 patients with senile cataract candidates for phacoemulsification and implantation of the Acriva Reviol Tri-ED (Group 1-18 eyes) and the AcrySof IQ Monofocal IOL SN60WF (Group 2-18 eyes). The main outcome measures, over a 6-month follow-up period, were uncorrected and corrected visual acuity at different distances (40, 60 cm and 4 m), defocus curve, contrast sensitivity and wavefront error. Patient satisfaction was evaluated by means of the NEI-RQL-42 questionnaire. Results: At 180 days postoperatively, the difference of the UCDVA and CDVA between the groups was not statistically significant (p = 0.888 and p = 0.843, respectively). The difference between the groups was statistically significant for UCIVA (p = 0.019) and UCNVA (p = 0.036). The mean values of contrast sensitivity under photopic and mesopic conditions were not significantly different between the groups. The RMS of spherical aberration was significantly lower in Group 1 compared to Group 2. The NEI-RQL-42 questionnaire showed statistically significant differences between the groups for the dependence on correction (p < 0.001). Conclusions: The diffractive trifocal IOL with enhanced depth of focus Acriva Reviol Tri-ED was effective in improving functional capacity for intermediate and near vision compared to monofocal IOLs and provided a good quality of vision due to a significant reduction in spherical aberration.
引用
收藏
页数:13
相关论文