Characterization of a GaAs photon-counting detector for mammography

被引:8
|
作者
Ghammraoui, Bahaa [1 ]
Gkoumas, Spyridon [2 ]
Glick, Stephen J. [1 ]
机构
[1] US FDA, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
[2] DECTRIS Ltd, Baden, Switzerland
关键词
x-ray detectors; photon-counting detector; breast mammography; GaAs detector; SPECTRAL MAMMOGRAPHY; DIGITAL MAMMOGRAPHY; QUANTUM EFFICIENCY; RAY;
D O I
10.1117/1.JMI.8.3.033504
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the potential of a prototype gallium arsenide (GaAs) photon-counting detector (PCD) for imaging of the breast. Approach: First, the contrast-to-noise ratio (CNR) using different aluminum/poly(methyl methacrylate) (PMMA) phantoms of different thicknesses were measured. Second, microcalcification detection accuracy using a receiver operating characteristic study with three observers reading an ensemble of images was measured. Finally, the feasibility of using a GaAs system with two energy bins for contrast-enhanced mammography was investigated. Results: For the first two studies, the GaAs detector was compared with a commercial mammography system. The CNR was estimated by imaging 18-, 36-, and 110-mu m-thick aluminum targets placed on top of 6 cm of PMMA plates and was found to be similar or better over a range of exposures. We observed a similar performance of detecting microcalcifications with the GaAs detector over a range of clinically applicable dose levels with a small increase at lower dose levels. The results also showed that contrast-enhanced spectral mammography using a GaAs PCD is feasible and beneficial. Conclusions: Results from this study suggest that performance with this new detector seems either slightly improved or equivalent to a commercial mammography system that used an energy-integrated detector. No attempt at optimizing exposure techniques for the GaAs detector was performed. Further research is needed to determine optimal acquisition parameters for the GaAs detector and to develop more sophisticated material decomposition algorithms that promise to provide improved quantitative estimates of iodine uptake. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:14
相关论文
共 50 条
  • [21] The Dosepix detector - an energy-resolving photon-counting pixel detector for spectrometric measurements
    Zang, A.
    Anton, G.
    Ballabriga, R.
    Bisello, F.
    Campbell, M.
    Celi, J. C.
    Fauler, A.
    Fiederle, M.
    Jensch, M.
    Kochanski, N.
    Llopart, X.
    Michel, N.
    Mollenhauer, U.
    Ritter, I.
    Tennert, F.
    Woelfel, S.
    Wong, W.
    Michel, T.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [22] Multispectral photon-counting for medical imaging and beam characterization
    Brucken, E.
    Bharthuar, S.
    Emzir, M.
    Golovleva, M.
    Gadda, A.
    Hostettler, R.
    Harkonen, J.
    Kirschenmann, S.
    Litichevskyi, V.
    Luukka, P.
    Martikainen, L.
    Naaranoja, T.
    Ninca, I.
    Ott, J.
    Petrow, H.
    Purisha, Z.
    Siiskonen, T.
    Sarkka, S.
    Tikkanen, J.
    Tuuva, T.
    Winkler, A.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (02):
  • [23] Detector motion method to increase spatial resolution in photon-counting detectors
    Daehee Lee
    Kyeongjin Park
    Kyung Taek Lim
    Gyuseong Cho
    Journal of the Korean Physical Society, 2017, 70 : 567 - 573
  • [24] Detector Motion Method to Increase Spatial Resolution in Photon-Counting Detectors
    Lee, Daehee
    Park, Kyeongjin
    Lim, Kyung Taek
    Cho, Gyuseong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 70 (06) : 567 - 573
  • [25] Detective quantum efficiency of a silicon microstrip photon-counting detector having edge-on geometry under mammography imaging condition
    Yun, S.
    Kim, H. K.
    Youn, H.
    Joe, O.
    Kim, S.
    Park, J.
    Kang, D. G.
    Sung, Y. H.
    Marchal, J.
    Tanguay, J.
    Cunningham, I. A.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [26] Characterization of a Pixelated CdTe X-Ray Detector Using the Timepix Photon-Counting Readout Chip
    Ruat, Marie
    Ponchut, Cyril
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 2392 - 2401
  • [27] Tutorial on X-ray photon counting detector characterization
    Ren, Liqiang
    Zheng, Bin
    Liu, Hong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (01) : 1 - 28
  • [28] A project for digital mammography based on a GaAs pixel detector and on a self-triggering single photon counting acquisition system
    Amendolia, SR
    Bertolucci, E
    Bottigli, U
    Ciocci, MA
    Cola, A
    Conti, M
    Delogu, P
    Fantacci, ME
    Magistrati, G
    Pernigotti, E
    Romeo, N
    Russo, P
    Stefanini, A
    Stumbo, S
    PHYSICA MEDICA, 1997, 13 (04) : 157 - 165
  • [29] Feasibility study of contrast enhanced digital mammography based on photon-counting detector by projection-based weighting technique: A simulation study
    Lee, Minjae
    Lee, Donghoon
    Jo, Byungdu
    Kim, Hyemi
    Kim, Dohyeon
    Choi, Seungyeon
    Kim, Hee-Joung
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [30] Photon-counting CT review
    Flohr, Thomas
    Petersilka, Martin
    Henning, Andre
    Ulzheimer, Stefan
    Ferda, Jiri
    Schmidt, Bernhard
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 : 126 - 136