Scanning of a Double-Sided Germanium Strip Detector

被引:4
|
作者
Sharma, Arzoo [1 ,3 ]
Palit, R. [2 ]
Kojouharov, I [3 ]
Gerl, J. [3 ]
Gorska-Ott, M. [3 ]
Schaffner, H. [3 ]
Habermann, T. [3 ]
Saha, S. [4 ]
Das, Biswajit [2 ]
Dey, P. [2 ]
Donthi, R. [2 ]
Naidu, B. S. [2 ]
Mandal, S. [5 ]
Singh, Pushpendra P. [1 ]
机构
[1] Indian Inst Technol Ropar, Dept Phys, Rupnagar 140001, Punjab, India
[2] Tata Inst Fundamental Res, Dept Nucl & Atom Phys, Homi Bhabha Rd, Mumbai 400005, Maharashtra, India
[3] GSI Helmholtzzentrum Schwerionenforsch GmbH, Planckstr 1, D-64291 Darmstadt, Germany
[4] Univ Massachusetts Lowell, Lowell, MA 01854 USA
[5] Univ Delhi, Dept Phys, North Campus, Delhi 110007, India
关键词
Double-Sided Strip Detector; Positron Annihilation Correlation; Position Sensitive Detector; Pulse Shape Analysis; POSITION;
D O I
10.1051/epjconf/202125311009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work presents the results from the characterization of a Position-Sensitive Planar Germanium (PSPGe) detector. The PSPGe detector is a double-sided orthogonal strip detector consisting of 10x10 electrical segmentation along the horizontal and vertical directions. The characterization was performed using the coincidence setup between the PSPGe detector and the well-characterized scanning system employing the positron annihilation correlation principle. The scanning system consists of a Position Sensitive Detector (PSD) and Na-22 positron source. The main objective of this study is to deploy PSPGe detector for future decay experiments at the Facility for Antiproton and Ion Research (FAIR), Germany. The measurements have been performed to find the depth of gamma-ray interaction in the planar segmented detector. The 2-Dimensional image obtained from the PSD has been used to find the depth of gamma-ray interaction in the planar strip detector using pulse shape analysis. In addition, the sensitivity of PSPGe detector has been investigated by calculating the rise-time from pulse shapes for the front and back strips of the detector.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] CMOS readout system for a double-sided germanium strip detector
    Kroeger, RA
    Johnson, WN
    Kurfess, JD
    Schwarz, WG
    Read, ME
    Allen, MD
    Alley, GT
    Britton, CL
    Clonts, LC
    Ericson, MN
    Simpson, ML
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 691 - 693
  • [2] CAPACITIVE CHARGE DIVISION READOUT OF A DOUBLE-SIDED GERMANIUM STRIP DETECTOR
    INDERHEES, SE
    KROEGER, RA
    JOHNSON, WN
    KINZER, RL
    KURFESS, JD
    GEHRELS, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 428 - 431
  • [3] Mapping the Response of a Double-Sided Strip High-Purity Germanium Detector
    Perea, Rose S.
    Furenlid, Lars
    Shokouhi, Sepideh
    Peterson, Todd E.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [4] Inter-Strip Interpolation Measurements in a High-Purity Germanium Double-Sided Strip Detector
    Hayward, Jason P.
    Wehe, David K.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 800 - 807
  • [5] Charge Loss Correction in a High-Purity Germanium Double-Sided Strip Detector
    Hayward, Jason P.
    Wehe, David K.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2789 - 2797
  • [6] INTERSTRIP CAPACITANCE OF THE DOUBLE-SIDED SILICON STRIP DETECTOR
    YAMAMOTO, K
    MURAMATSU, M
    YAMAMURA, K
    OHMURA, M
    UTSUYAMA, H
    ANZAI, H
    SAITO, K
    KONMURA, M
    NAKAMURA, M
    NIWA, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (06) : 2021 - 2025
  • [7] Development and test of double-sided silicon strip detector
    Sun, Li-Jie
    Lin, Cheng-Jian
    Yang, Feng
    Guo, Zhao-Qiao
    Guo, Tian-Shu
    Xu, Xin-Xing
    Bao, Peng-Fei
    Yang, Lei
    Jia, Hui-Ming
    Ma, Nan-Ru
    Zhang, Huan-Qiao
    Liu, Zu-Hua
    Xia, Qing-Liang
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (02): : 336 - 342
  • [8] High efficiency beta-decay spectroscopy using a planar germanium double-sided strip detector
    Larson, N.
    Liddick, S. N.
    Bennett, M.
    Bowe, A.
    Chemey, A.
    Prokop, C.
    Simon, A.
    Spyrou, A.
    Suchyta, S.
    Quinn, J.
    Tabor, L.
    Tai, P. L.
    Tripathi, Vandana
    VonMoss, J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 727 : 59 - 64
  • [9] Incomplete charge collection in an HPGe double-sided strip detector
    Hayward, Jason
    Wehe, David
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 586 (02): : 215 - 223
  • [10] Characterization of a double-sided silicon strip detector autoradiography system
    Orbom, Anders
    Ahlstedt, Jonas
    Seren, Tom
    Auterinen, Iiro
    Kotiluoto, Petri
    Hauge, Havard
    Ostlund, Karl
    Olafsen, Tove
    Wu, Anna M.
    Dahlbom, Magnus
    Strand, Sven-Erik
    MEDICAL PHYSICS, 2015, 42 (02) : 575 - 584