Experimental studies on booster lens thermosyphon solar water heating system

被引:1
作者
Jaisankar, S. [1 ]
SenthilKumar, T. [2 ]
Arulmozhi, M. [3 ]
Karthik, R. [2 ]
机构
[1] Star Lion Coll Engn & Technol, Dept Mech Engn, Thanjavur 614206, India
[2] Anna Univ, Dept Mech Engn, Univ Coll Engn, BIT Campus, Trichy 620024, India
[3] Anna Univ, Dept Petrochem Engn, Univ Coll Engn, BIT Campus, Trichy 620024, India
关键词
Booster lens collector; Thermosyphon; Solar insolation; Floating glass; Efficiency; FLAT-PLATE COLLECTORS; THERMAL PERFORMANCE; HEATER; DESIGN; ENHANCEMENT; IMPROVEMENT;
D O I
10.1007/s10973-022-11260-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental studies on real conventional and modified thermosyphon (booster lens) solar flat plate collectors have been carried out from 9.00 am to 4.00 pm in open atmosphere. The mass flow rate, instantaneous heat gain and efficiency increase gradually from 9.30 am to 1.30 pm and decreases from 1.30 pm to 4.00 pm. The average mass flow rate obtained by booster lens collector is compared to conventional and is 18.1%. The highest heat gain noticed at 1.30 pm is 375.51 J s(-1) and 439.97 J s(-1) for real conventional and modified thermosyphon collector, respectively. Experimental outcome exposed that the average heat intensification and thermal performance for modified thermosyphon collector have 24.25% and 25.1% higher than the real conventional one. The experimental nusselt number and friction factor compared with Sieder-Tate and fanning equation and deviation falls with in 7.41% and 14% respectively.
引用
收藏
页码:11289 / 11299
页数:11
相关论文
共 50 条
[41]   Solar water heating systems and their market trends [J].
Islam, M. Raisul ;
Sumathy, K. ;
Khan, Samee Ullah .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 17 :1-25
[42]   Experimental Validation of Exergy Optimization of a Flat-Plate Solar Collector in a Thermosyphon Solar Water Heater [J].
Wenceslas, Kohole Yemeli ;
Ghislain, Tchuen .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2019, 44 (03) :2535-2549
[43]   OPTIMAL DESIGN FOR A THERMOSYPHON SOLAR WATER HEATER CONVENIENT FOR MALAYSIA [J].
Zahedi, H. R. ;
Adam, N. M. ;
Sapuan, S. M. ;
Ahmad, M. M. H. M. .
MULTIDISCIPLINE MODELING IN MATERIALS AND STRUCTURES, 2009, 5 (03) :247-250
[44]   DESIGN AND EXPERIMENTAL STUDY OF A SOLAR SYSTEM FOR HEATING WATER UTILIZING A LINEAR FRESNEL REFLECTOR [J].
Ghodbane, M. ;
Boumeddane, B. ;
Said, N. .
JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2016, 8 (03) :804-825
[45]   Optimization of the Parameters of Solar Water Heating System [J].
Iljins, U. ;
Ziemelis, I. ;
Putans, U. ;
Skele, A. ;
Navickas, I. .
ENVIRONMENT, TECHNOLOGY, RESOURCES, PROCEEDINGS, 2003, :353-358
[46]   EXPERIMENTAL INVESTIGATION OF SOLAR STILLS INTEGRATED WITH SOLAR WATER HEATING COLLECTORS [J].
Emin, E. L. ;
Cakmak, Gulsah ;
Argunhan, Zeki ;
Yildiz, Cengiz .
ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2017, 37 (02) :97-107
[47]   Thermal performance of a thermosyphon heat pipe evacuated tube solar collector using silver-water nanofluid for commercial applications [J].
Ozsoy, Ahmet ;
Corumlu, Vahit .
RENEWABLE ENERGY, 2018, 122 :26-34
[48]   Performance Studies and Energy-Saving Analysis of a Solar Water-Heating System [J].
Han, Xilian ;
Li, Chao ;
Ma, Hongqiang .
PROCESSES, 2021, 9 (09)
[49]   Performance of Thermosyphon Solar Water Heaters in Series [J].
Liu, Yi-Mei ;
Chung, Kung-Ming ;
Chang, Keh-Chin ;
Lee, Tsong-Sheng .
ENERGIES, 2012, 5 (09) :3266-3278
[50]   Experimental and numerical analysis of a parabolic trough solar collector for water heating application [J].
ozcan, Abdulkadir ;
Devecioglu, Atilla Gencer ;
Oruc, Vedat .
ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (02) :4184-4203