Enantioseparation of of four amide herbicide stereoisomers using high-performance liquid chromatography

被引:24
|
作者
Xie, Jingqian [1 ]
Zhao, Lu [1 ]
Liu, Kai [2 ]
Guo, Fangjie [1 ]
Liu, Weiping [1 ]
机构
[1] Zhejiang Univ, Coll Environm & Resource Sci, MOE Key Lab Environm Remediat & Ecosyst Hlth, Hangzhou 310058, Zhejiang, Peoples R China
[2] CALTECH, WM Keck Labs, Div Engn & Appl Sci, 1200 East Calif Blvd, Pasadena, CA 91125 USA
基金
中国国家自然科学基金;
关键词
Chirality; Amide herbicides; Enantioseparation; Absolute configuration; Separation mechanisms; ENANTIOMERIC RESOLUTION; SEPARATIONS; HPLC;
D O I
10.1016/j.chroma.2016.10.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The chirality of herbicides has been the focus of research. However, there is little information on the enantioseparation of amide herbicides with different chiral elements. In this study, the need for different chiral stationary phases (CSPs), mobile phases, temperatures and flow rates for the separation of napropamide, acetochlor and propisochlor was discussed in detail and compared to metolachlor. Resolution of C-chiral enantiomers was easier than that of axial-chiral enantiomers. Metolachlor and acetochlor could achieve baseline separation only on AY-H and AS-H columns, respectively. Propisochlor had satisfactory separations on OD-H and AS-H columns. Napropamide was separated on OJ-H, AY-H and AS-H columns. Both the structures of the compounds and CSPs and the interactions between them played significant roles in the enantioseparations. Molecule dockings were also used to elucidate the separation mechanisms. C-chiral enantiomers had perfect symmetry in their optical properties, whereas the axial-chiral enantiomers did not. The elution order for napropamide, acetochlor and propisochlor, with a single chiral location, was R- prior to S-. These results were the first that compare the enantioseparations of four amide herbicides with different chirality, and they provided the absolute configurations for the herbicides. The paper also illustrated certain mechanisms for enantioseparations. (C) 2016 Elsevier B.V. All rights reserved,
引用
收藏
页码:145 / 154
页数:10
相关论文
共 50 条
  • [1] Determination of Four Nadolol Stereoisomers in Capsules by High-Performance Liquid Chromatography and Circular Dichroism
    Alexandre, Grazielle Prado
    Wandermuren, Marcio Nardelli
    Peron, Adriano
    Tavares, Vanessa Franco
    Ramalho Padeiro, Denis Alexandre
    Sakiara, Kelly Alessandra
    Aurora-Prado, Maria Segunda
    Singh, Anil Kumar
    Maria Kedor-Hackmann, Erika Rosa
    Rocha Meritello Santoro, Maria Ines
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (04) : 1016 - 1022
  • [2] Enantioseparation of phenethylamines by using high-performance liquid chromatography column permanently coated with methylated β-cyclodextrin
    Terashima, Hiroyuki
    Yamamoto, Atsushi
    Aizawa, Sen-ichi
    Taga, Atsushi
    Mikami, Ikko
    Ishihara, Yoshimi
    Kodama, Shuji
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (15) : 2932 - 2940
  • [3] Enantioseparation of benazepril intermediates by high-performance liquid chromatography on chiral CDMPC column
    Chen, Juanjuan
    Shen, Baochun
    Zhang, Xuejun
    Xu, Xiuzhu
    ANALYTICAL LETTERS, 2007, 40 (01) : 173 - 182
  • [4] ENANTIOSEPARATION OF INDAPAMIDE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING OVOMUCOID GLYCOPROTEIN AS CHIRAL SELECTOR
    Carje, Anca Gabriela
    Ion, Valentin
    Muntean, Daniela-Lucia
    Hancu, Gabriel
    Balint, Alina
    Imre, Silvia
    FARMACIA, 2016, 64 (02) : 181 - 186
  • [5] Enantioseparation using amylose esters as chiral stationary phases for high-performance liquid chromatography
    Yuri Sugiura
    Chiyo Yamamoto
    Tomoyuki Ikai
    Masami Kamigaito
    Yoshio Okamoto
    Polymer Journal, 2010, 42 : 31 - 36
  • [6] Enantioseparation using amylose esters as chiral stationary phases for high-performance liquid chromatography
    Sugiura, Yuri
    Yamamoto, Chiyo
    Ikai, Tomoyuki
    Kamigaito, Masami
    Okamoto, Yoshio
    POLYMER JOURNAL, 2010, 42 (01) : 31 - 36
  • [7] Superiority of thin-layer chromatography over high-performance liquid chromatography in enantioseparation
    Dipshi Singh
    Poonam Malik
    Ravi Bhushan
    JPC – Journal of Planar Chromatography – Modern TLC, 2019, 32 : 7 - 12
  • [8] Enantioseparation of 38 Racemates on Four Chiral Columns in High Performance Liquid Chromatography
    Zhang Mei
    Xi Wen-Hui
    Zi Min
    Peng Ya
    Xie Sheng-Ming
    Yuan Li-Ming
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (02) : 181 - 186
  • [9] Superiority of Thin-Layer Chromatography over High-Performance Liquid Chromatography in Enantioseparation
    Singh, Dipshi
    Malik, Poonam
    Bhushan, Ravi
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2019, 32 (01) : 7 - 12
  • [10] Enantioseparation using alkoxyphenylcarbamates of cellulose and amylose as chiral stationary phase for high-performance liquid chromatography
    Yamamoto, C
    Inagaki, S
    Okamoto, Y
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (06) : 915 - 923