Quantifying variability in radiation dose due to respiratory-induced tumor motion

被引:13
作者
Geneser, S. E. [1 ]
Hinkle, J. D. [1 ]
Kirby, R. M. [1 ]
Wang, B. [2 ]
Salter, B. [2 ]
Joshi, S. [1 ]
机构
[1] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT USA
[2] Univ Utah, Huntsman Canc Inst, Salt Lake City, UT USA
关键词
Respiratory-induced dose variation; Stochastic modeling; Polynomial chaos; Stochastic collocation; Stereotactic body radiation therapy; ORGAN MOTION; DIFFERENTIAL-EQUATIONS; IMAGE REGISTRATION; LUNG MOTION; THERAPY; CT; UNCERTAINTY; MANAGEMENT; DELIVERY; IMPACT;
D O I
10.1016/j.media.2010.07.003
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
State of the art radiation treatment methods such as hypo-fractionated stereotactic body radiation therapy (SBRT) can successfully destroy tumor cells and avoid damaging healthy tissue by delivering high-level radiation dose that precisely conforms to the tumor shape. Though these methods work well for stationary tumors, SBRT dose delivery is particularly susceptible to organ motion, and few techniques capable of resolving and compensating for respiratory-induced organ motion have reached clinical practice. The current treatment pipeline cannot accurately predict nor account for respiratory-induced motion in the abdomen that may result in significant displacement of target lesions during the breathing cycle. Sensitivity of dose deposition to respiratory-induced organ motion represents a significant challenge and may account for observed discrepancies between predictive treatment plan indicators and clinical patient outcomes. Improved treatment-planning and delivery of SBRT requires an accurate prediction of dose deposition uncertainties resulting from respiratory motion. To accomplish this goal, we developed a framework that models both organ displacement in response to respiration and the underlying random variations in patient-specific breathing patterns. Our organ deformation model is a four-dimensional maximum a posteriori (MAP) estimation of tissue deformation as a function of chest wall amplitudes computed from clinically obtained respiratory-correlated computed tomography (RCCT) images. We characterize patient specific respiration as the probability density function (PDF) of chest wall amplitudes and model patient breathing patterns as a random process. We then combine the patient-specific organ motion and stochastic breathing models to calculate the resulting variability in radiation dose accumulation. This process allows us to predict uncertainties in dose delivery in the presence of organ motion and identify tissues at risk of receiving insufficient or harmful levels of radiation. (C) 2010 Elsevier By. All rights reserved.
引用
收藏
页码:640 / 649
页数:10
相关论文
共 68 条
  • [1] Phase and amplitude binning for 4D-CT imaging
    Abdelnour, A. F.
    Nehmeh, S. A.
    Pan, T.
    Humm, J. L.
    Vernon, P.
    Schoder, H.
    Rosenzweig, K. E.
    Mageras, G. S.
    Yorke, E.
    Larson, S. M.
    Erdi, Y. E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12) : 3515 - 3529
  • [2] [Anonymous], 2003, NASACR2003212153
  • [3] [Anonymous], 1997, Internat. Ser. Numer. Math. Birkhauser, DOI DOI 10.1007/978-3-0348-8871-4
  • [4] BABUSKA I, 2005, 0547 ICES U TEX AUST
  • [5] Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT
    Beddar, A. Sam
    Kainz, Kristofer
    Briere, Tina Marie
    Tsunashima, Yoshikazu
    Pan, Tinsu
    Prado, Karl
    Mohan, Radhe
    Gillin, Michael
    Krishnan, Sunil
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (02): : 630 - 638
  • [6] Computing large deformation metric mappings via geodesic flows of diffeomorphisms
    Beg, MF
    Miller, MI
    Trouvé, A
    Younes, L
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 2005, 61 (02) : 139 - 157
  • [7] 4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis
    Boldea, Vlad
    Sharp, Gregory C.
    Jiang, Steve B.
    Sarrut, David
    [J]. MEDICAL PHYSICS, 2008, 35 (03) : 1008 - 1018
  • [8] Effects of motion on the total dose distribution
    Bortfeld, T
    Jiang, SB
    Rietzel, E
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) : 41 - 51
  • [9] Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation
    Bortfeld, T
    Jokivarsi, K
    Goitein, M
    Kung, J
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (13) : 2203 - 2220
  • [10] Intensity-modulated radiotherapy: Current status and issues of interest
    Boyer, AL
    Butler, EB
    DiPetrillo, TA
    Engler, MJ
    Fraass, B
    Grant, W
    Ling, CC
    Low, DA
    Mackie, TR
    Mohan, R
    Purdy, JA
    Roach, M
    Rosenman, JG
    Verhey, LJ
    Wong, JW
    Cumberlin, RL
    Stone, H
    Palta, JR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04): : 880 - 914