Proposal of a novel compact cold atomic fountain clock

被引:0
|
作者
Wei, R [1 ]
Qian, Y [1 ]
Zhang, Y [1 ]
Wang, YZ [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Key Lab Quantum Opt, Shanghai 201800, Peoples R China
关键词
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We propose a novel atomic fountain clock which is compact and transportable. The clock is 60-cm in height. Its linewidth is expected to be 1.75Hz, with accuracy 10(-14), stability 10(-14) and signal-noise ratio 10(3). A hollow. beam is applied as atomic wave-guide, which can increase the stability and the signal-noise ratio by one order. The hollow beam will not affect the accuracy of the clock, if the frequency shift due to the hollow beam is amended and the fluctuation of the hollow beam intensity is controlled to be smaller than 0.6%.
引用
收藏
页码:57 / 60
页数:4
相关论文
共 50 条
  • [41] Portable compact cold atoms clock topology
    Pechoneri, R. D.
    Mueller, S. T.
    Bueno, C.
    Bagnato, V. S.
    Magalhaes, D. V.
    8TH BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2015), 2016, 733
  • [42] Stability of the compact cold atom clock HORACE
    Esnault, F. X.
    Perrin, S.
    Tremine, S.
    Guerandel, S.
    Holleville, D.
    Dimarcq, N.
    Hermann, V.
    Delporte, J.
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM-JOINTLY WITH THE 21ST EUROPEAN FREQUENCY AND TIME FORUM, VOLS 1-4, 2007, : 1342 - +
  • [43] Cold Atom Gravimeter Based on an Atomic Fountain and a Microwave Transition
    A. E. Afanasiev
    P. I. Skakunenko
    V. I. Balykin
    JETP Letters, 2024, 119 : 84 - 88
  • [44] Cold Atom Gravimeter Based on an Atomic Fountain and a Microwave Transition
    Afanasiev, A. E.
    Skakunenko, P. I.
    Balykin, V. I.
    JETP LETTERS, 2024, 119 (02) : 84 - 88
  • [45] Collisions in a ballistically expanding cloud of cold atoms in an atomic fountain
    Chalupczak, Witold
    Szymaniec, Krzysztof
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2007, 40 (02) : 343 - 350
  • [46] Proposal of a truncated atomic beam fountain for reduction of collisional frequency shift
    Takamizawa, A.
    Shirakawa, Y.
    Yanagimachi, S.
    Ikegami, T.
    PHYSICAL REVIEW A, 2010, 82 (01):
  • [47] Fountain Clock Accuracy
    Gibble, Kurt
    2012 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), 2012, : 16 - 18
  • [48] A Cold Atomic Beam Ramsey CPT Clock
    Elgin, John D.
    Heavner, Thomas P.
    Kitching, John
    Donley, Elizabeth A.
    Denney, Jayson
    Salim, Evan
    2018 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (IFCS), 2018, : 29 - 30
  • [49] Characterization of the collisional frequency shift in an atomic fountain clock using absorption imaging
    Beattie, Scott
    Jian, Bin
    METROLOGIA, 2023, 60 (04)
  • [50] A high stability atomic fountain clock using a cryogenic sapphire interrogation oscillator
    Mann, AG
    Santarelli, G
    Chang, S
    Luiten, AN
    Laurent, P
    Salomon, C
    Blair, DG
    Clairon, A
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1998, : 13 - 17