Simultaneous Mapping of T1 and T2 Using Cardiac Magnetic Resonance Fingerprinting in a Cohort of Healthy Subjects at 1.5T

被引:31
作者
Hamilton, Jesse I. [1 ,2 ]
Pahwa, Shivani [3 ]
Adedigba, Joseph [3 ]
Frankel, Samuel [3 ]
O'Connor, Gregory [3 ]
Thomas, Rahul [3 ]
Walker, Jonathan R. [3 ]
Killinc, Ozden [3 ]
Lo, Wei-Ching [2 ]
Batesole, Joshua [3 ]
Margevicius, Seunghee [4 ]
Griswold, Mark [2 ,3 ]
Rajagopalan, Sanjay [3 ,5 ]
Gulani, Vikas [1 ,2 ,3 ]
Seiberlich, Nicole [1 ,2 ,3 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Univ Hosp Cleveland Med Ctr, Dept Radiol, Cleveland, OH USA
[4] Case Western Reserve Univ, Dept Populat & Quantitat Hlth Sci, Cleveland, OH 44106 USA
[5] Univ Hosp Cleveland Med Ctr, Div Cardiovasc Med, Cleveland, OH 44106 USA
基金
美国国家科学基金会;
关键词
magnetic resonance fingerprinting; parameter mapping; spiral; relaxation times; MYOCARDIAL T-1; T1; MOLLI; RECOVERY; SASHA;
D O I
10.1002/jmri.27155
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Cardiac MR fingerprinting (cMRF) is a novel technique for simultaneous T-1 and T-2 mapping. Purpose To compare T-1/T-2 measurements, repeatability, and map quality between cMRF and standard mapping techniques in healthy subjects. Study Type Prospective. Population In all, 58 subjects (ages 18-60). Field Strength/Sequence cMRF, modified Look-Locker inversion recovery (MOLLI), and T-2-prepared balanced steady-state free precession (bSSFP) at 1.5T. Assessment T-1/T-2 values were measured in 16 myocardial segments at apical, medial, and basal slice positions. Test-retest and intrareader repeatability were assessed for the medial slice. cMRF and conventional mapping sequences were compared using ordinal and two alternative forced choice (2AFC) ratings. Statistical Tests Paired t-tests, Bland-Altman analyses, intraclass correlation coefficient (ICC), linear regression, one-way analysis of variance (ANOVA), and binomial tests. Results Average T-1 measurements were: basal 1007.4 +/- 96.5 msec (cMRF), 990.0 +/- 45.3 msec (MOLLI); medial 995.0 +/- 101.7 msec (cMRF), 995.6 +/- 59.7 msec (MOLLI); apical 1006.6 +/- 111.2 msec (cMRF); and 981.6 +/- 87.6 msec (MOLLI). Average T-2 measurements were: basal 40.9 +/- 7.0 msec (cMRF), 46.1 +/- 3.5 msec (bSSFP); medial 41.0 +/- 6.4 msec (cMRF), 47.4 +/- 4.1 msec (bSSFP); apical 43.5 +/- 6.7 msec (cMRF), 48.0 +/- 4.0 msec (bSSFP). A statistically significant bias (cMRF T-1 larger than MOLLI T-1) was observed in basal (17.4 msec) and apical (25.0 msec) slices. For T-2, a statistically significant bias (cMRF lower than bSSFP) was observed for basal (-5.2 msec), medial (-6.3 msec), and apical (-4.5 msec) slices. Precision was lower for cMRF-the average of the standard deviation measured within each slice was 102 msec for cMRF vs. 61 msec for MOLLI T-1, and 6.4 msec for cMRF vs. 4.0 msec for bSSFP T-2. cMRF and conventional techniques had similar test-retest repeatability as quantified by ICC (0.87 cMRF vs. 0.84 MOLLI for T-1; 0.85 cMRF vs. 0.85 bSSFP for T-2). In the ordinal image quality comparison, cMRF maps scored higher than conventional sequences for both T-1 (all five features) and T-2 (four features). Data Conclusion This work reports on myocardial T-1/T-2 measurements in healthy subjects using cMRF and standard mapping sequences. cMRF had slightly lower precision, similar test-retest and intrareader repeatability, and higher scores for map quality. Evidence Level 2 Technical Efficacy Stage 1
引用
收藏
页码:1044 / 1052
页数:9
相关论文
共 40 条
[1]  
Ahad J, 2018, P 26 ANN M ISMRM PAR, P4789
[2]   Joint Myocardial T1 and T2 Mapping Using a Combination of Saturation Recovery and T2-preparation [J].
Akcakaya, Mehmet ;
Weingaertner, Sebastian ;
Basha, Tamer A. ;
Roujol, Sebastien ;
Bellm, Steven ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) :888-896
[3]  
[Anonymous], 2012, J CARDIOVASC MAGN R, DOI [DOI 10.1186/1532-429X-14-83, DOI 10.1186/1532-429X-15-53]
[4]   Pseudo Steady-State Free Precession for MR-Fingerprinting [J].
Asslaender, Jakob ;
Glaser, Steffen J. ;
Hennig, Juergen .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) :1151-1161
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Performance of T1 and T2 Mapping Cardiovascular Magnetic Resonance to Detect Active Myocarditis in Patients With Recent-Onset Heart Failure [J].
Bohnen, Sebastian ;
Radunski, Ulf K. ;
Lund, Gunnar K. ;
Kandolf, Reinhard ;
Stehning, Christian ;
Schnackenburg, Bernhard ;
Adam, Gerhard ;
Blankenberg, Stefan ;
Muellerleile, Kai .
CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (06)
[7]   Robust free-breathing SASHA T1 mapping with high-contrast image registration [J].
Chow, Kelvin ;
Yang, Yang ;
Shaw, Peter ;
Kramer, Christopher M. ;
Salerno, Michael .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
[8]   Saturation Recovery Single-Shot Acquisition (SASHA) for Myocardial T1 Mapping [J].
Chow, Kelvin ;
Flewitt, Jacqueline A. ;
Green, Jordin D. ;
Pagano, Joseph J. ;
Friedrich, Matthias G. ;
Thompson, Richard B. .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) :2082-2095
[9]   Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging [J].
Christodoulou, Anthony G. ;
Shaw, Jaime L. ;
Nguyen, Christopher ;
Yang, Qi ;
Xie, Yibin ;
Wang, Nan ;
Li, Debiao .
NATURE BIOMEDICAL ENGINEERING, 2018, 2 (04) :215-226
[10]   MR fingerprinting Deep RecOnstruction NEtwork (DRONE) [J].
Cohen, Ouri ;
Zhu, Bo ;
Rosen, Matthew S. .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (03) :885-894