Highly Sensitive Lanthanide-Doped Nanoparticles-Based Point-of-Care Diagnosis of Human Cardiac Troponin I

被引:12
作者
Chen, Lu [1 ]
Zhou, Shan-Yong [2 ]
Zhu, Wei [3 ]
Liu, Sheng-Ping [4 ]
Zhang, Jing-Xi [5 ]
Zhuang, He [5 ]
Zhang, Jing-Ling [5 ]
Li, Yong-Sheng [6 ]
Gao, Fei [4 ]
机构
[1] Fujian Matern & Child Hlth Hosp, Dept Paediat, Fuzhou 350000, Peoples R China
[2] Chinese Acad Sci, Fujian Inst Res Struct Matter, Fujian Key Lab Nanomat, Fuzhou 350002, Peoples R China
[3] Fujian Med Univ, Shengli Clin Med Coll, Fujian Prov Hosp, Dept Urol, Fuzhou 350001, Peoples R China
[4] Fujian Med Univ Union Hosp, Fujian Inst Hematol, Fujian Prov Key Lab Hematol, Fuzhou 350001, Peoples R China
[5] Fujian Med Univ Union Hosp, Dept Clin Lab, Fuzhou 350001, Fujian, Peoples R China
[6] Fujian Med Univ Union Hosp, Dept Urol, Fuzhou 350001, Peoples R China
关键词
cardiac troponin I; GdVO; 4; 30% Eu NPs; lateral flow test strip; point-of-care test; ACUTE MYOCARDIAL-INFARCTION; HYDROTHERMAL SYNTHESIS; MAGNETIC-PROPERTIES; PHOTOLUMINESCENCE; LUMINESCENT; NANOCRYSTALS; PROTEIN; SIZE; EU;
D O I
10.2147/IJN.S346415
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Introduction: Cardiac troponin I (cTnI) has been regarded as a gold standard for early diagnosis and prognosis monitoring of acute myocardial infarction (AMI) in clinical practice. Owing to its low concentration in blood, accurate determination of cTnI often requires high sensitivity. However, current established point-of-care (POC) assays are insufficient to meet clinically analytical requirements due to their low sensitivity. Methods: To this end, we established a highly sensitive and reliable POC lateral flow strip based on lanthanide-doped nanoparticles (NPs) for cTnI determination in human blood samples. The capture of cTnI on the lateral flow strip was performed in a sandwich assay, where Eu3+-doped vanadate nanoparticles (GdVO4:30% Eu NPs) were used as luminescent probes to allow quantification. Results: Our platform realized the analytical sensitivity enhancement with limit-of-detection (LOD) as low as 17 pg mL-1 for cTnI detection, which was lower than the commercial counterpart; meanwhile, it displayed high specificity, excellent reproducibility and outstanding accuracy for analyzing clinical serum samples. Conclusion: Overall, this strategy provided an ultrasensitive, cost-effective and user-friendly platform for on-site cTnI detection, demonstrating the prospect of lanthanide-doped NPs-based POC diagnosis of disease-related biomarkers.
引用
收藏
页码:635 / 646
页数:12
相关论文
共 37 条
[31]   Performance Evaluation of Cardiac Troponin I Assay: A Comparison Between the Point-of-care Testing Radiometer AQT90 FLEX and the Central Laboratory Siemens Advia Centaur Analyzer [J].
Ahmed, Sibtain ;
Jafri, Lena ;
Raheem, Ahmed ;
Shakeel, Shahid ;
Siddiqui, Imran .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (03)
[32]   Simple, low-cost, sensitive and label-free aptasensor for the detection of cardiac troponin I based on a gold nanoparticles modified titanium foil [J].
Lopa, Nasrin Siraj ;
Rahman, Md. Mahbubur ;
Ahmed, Faiz ;
Ryu, Taewook ;
Sutradhar, Sabuj Chandra ;
Lei, Jin ;
Kim, Jaewoong ;
Kim, Dae Ho ;
Lee, Yong Hoon ;
Kim, Whangi .
BIOSENSORS & BIOELECTRONICS, 2019, 126 :381-388
[33]   Ultra-sensitive, rapid gold nanoparticle-quantum dot plexcitonic self-assembled aptamer-based nanobiosensor for the detection of human cardiac troponin I [J].
Rezaei, Zahra ;
Ranjbar, Bijan .
ENGINEERING IN LIFE SCIENCES, 2017, 17 (02) :165-174
[34]   Fouling-Free electrochemical strategy based on vertically-aligned peptide layer for cardiac troponin I sensitive detection in human serum [J].
Qin, Xingao ;
Ab, Xiaoyu ;
Zhu, Xiaoyu ;
Wang, Ying .
ANALYTICA CHIMICA ACTA, 2024, 1317
[35]   Highly sensitive and reproducible SERS substrate based on ordered multi-tipped Au nanostar arrays for the detection of myocardial infarction biomarker cardiac troponin I [J].
Xiang, Qing ;
Wang, Hao ;
Liu, Shengdong ;
Zheng, Yilong ;
Wang, Shipan ;
Zhang, Huanhuan ;
Min, Yonggang ;
Ma, Yuguang .
ANALYST, 2025, 150 (11) :2239-2250
[36]   Fabrication of Highly Sensitive Electrochemical Sensor Based on Chromium-Doped Ferrite Nanoparticles: Hybrid Graphene Nanosheets for the First Voltammetric Determination of Asenapine Maleate in Formulations and Human Plasma [J].
Gado, Mohamed S. ;
El-Desoky, Hanaa S. ;
Abdel-Galeil, Mohamed M. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (05)
[37]   Highly sensitive and selective label-free detection of dopamine in human serum based on nitrogen-doped graphene quantum dots decorated on Au nanoparticles: Mechanistic insights through microscopic and spectroscopic studies [J].
Das, Ruma ;
Paul, Kamal Kumar ;
Giri, P. K. .
APPLIED SURFACE SCIENCE, 2019, 490 :318-330