Highly Sensitive Lanthanide-Doped Nanoparticles-Based Point-of-Care Diagnosis of Human Cardiac Troponin I

被引:12
作者
Chen, Lu [1 ]
Zhou, Shan-Yong [2 ]
Zhu, Wei [3 ]
Liu, Sheng-Ping [4 ]
Zhang, Jing-Xi [5 ]
Zhuang, He [5 ]
Zhang, Jing-Ling [5 ]
Li, Yong-Sheng [6 ]
Gao, Fei [4 ]
机构
[1] Fujian Matern & Child Hlth Hosp, Dept Paediat, Fuzhou 350000, Peoples R China
[2] Chinese Acad Sci, Fujian Inst Res Struct Matter, Fujian Key Lab Nanomat, Fuzhou 350002, Peoples R China
[3] Fujian Med Univ, Shengli Clin Med Coll, Fujian Prov Hosp, Dept Urol, Fuzhou 350001, Peoples R China
[4] Fujian Med Univ Union Hosp, Fujian Inst Hematol, Fujian Prov Key Lab Hematol, Fuzhou 350001, Peoples R China
[5] Fujian Med Univ Union Hosp, Dept Clin Lab, Fuzhou 350001, Fujian, Peoples R China
[6] Fujian Med Univ Union Hosp, Dept Urol, Fuzhou 350001, Peoples R China
关键词
cardiac troponin I; GdVO; 4; 30% Eu NPs; lateral flow test strip; point-of-care test; ACUTE MYOCARDIAL-INFARCTION; HYDROTHERMAL SYNTHESIS; MAGNETIC-PROPERTIES; PHOTOLUMINESCENCE; LUMINESCENT; NANOCRYSTALS; PROTEIN; SIZE; EU;
D O I
10.2147/IJN.S346415
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Introduction: Cardiac troponin I (cTnI) has been regarded as a gold standard for early diagnosis and prognosis monitoring of acute myocardial infarction (AMI) in clinical practice. Owing to its low concentration in blood, accurate determination of cTnI often requires high sensitivity. However, current established point-of-care (POC) assays are insufficient to meet clinically analytical requirements due to their low sensitivity. Methods: To this end, we established a highly sensitive and reliable POC lateral flow strip based on lanthanide-doped nanoparticles (NPs) for cTnI determination in human blood samples. The capture of cTnI on the lateral flow strip was performed in a sandwich assay, where Eu3+-doped vanadate nanoparticles (GdVO4:30% Eu NPs) were used as luminescent probes to allow quantification. Results: Our platform realized the analytical sensitivity enhancement with limit-of-detection (LOD) as low as 17 pg mL-1 for cTnI detection, which was lower than the commercial counterpart; meanwhile, it displayed high specificity, excellent reproducibility and outstanding accuracy for analyzing clinical serum samples. Conclusion: Overall, this strategy provided an ultrasensitive, cost-effective and user-friendly platform for on-site cTnI detection, demonstrating the prospect of lanthanide-doped NPs-based POC diagnosis of disease-related biomarkers.
引用
收藏
页码:635 / 646
页数:12
相关论文
共 37 条
[21]   A New and Highly Sensitive Serum Mannoprotein Lateral Flow Assay for Point-of-Care Diagnosis of Invasive Aspergillosis (Tripathy Method) [J].
Chaturvedi, Chandra P. ;
Hashim, Zia ;
Tripathy, Naresh K. .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
[22]   Performance of ivisen IA-1400, a new point-of-care device with an internal centrifuge system, for the measurement of cardiac troponin I levels [J].
Kim, Ha Nui ;
Yoon, Soo-Young .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (05)
[23]   The 99th percentile and imprecision of point-of-care cardiac troponin I in comparison to central laboratory tests in a large reference population [J].
Greiser, Anne ;
Winter, Theresa ;
Mahfoud, Hala ;
Kallner, Anders ;
Ittermann, Till ;
Masuch, Annette ;
Lubenow, Norbert ;
Kohlmann, Thomas ;
Greinacher, Andreas ;
Nauck, Matthias ;
Petersmann, Astrid .
CLINICAL BIOCHEMISTRY, 2017, 50 (18) :1198-1202
[24]   Utilizing saliva for non-invasive detection of exercise-induced myocardial injury with point-of-care cardiac troponin-I [J].
Ovchinnikov, Aleksandr N. .
SCIENTIFIC REPORTS, 2025, 15 (01)
[25]   A Novel Two-Electrode Microchip-Based Electrochemiluminescence Point-of-Care Testing System for Rapid and Highly Sensitive Multiple Biomarkers Analysis [J].
Yuan, Haojun ;
Gao, Wanlei ;
Yang, Ping ;
Cao, Xinyi ;
Wu, Yangbo ;
Guo, Zhiyong ;
Cong, Hui ;
Zhang, Xiaowei ;
Jin, Qinghui .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
[26]   Predictive value of routine point-of-care cardiac troponin T measurement for prehospital diagnosis and risk-stratification in patients with suspected acute myocardial infarction [J].
Rasmussen, Martin B. ;
Stengaard, Carsten ;
Sorensen, Jacob T. ;
Riddervold, Ingunn S. ;
Hansen, Troels M. ;
Giebner, Matthias ;
Rasmussen, Claus-Henrik ;
Botker, Hans E. ;
Terkelsen, Christian J. .
EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2019, 8 (04) :299-308
[27]   A novel PCR-based point-of-care method facilitates rapid, efficient, and sensitive diagnosis of influenza virus infection [J].
Schmidt, R. L. J. ;
Simon, A. ;
Popow-Kraupp, T. ;
Laggner, A. ;
Haslacher, H. ;
Fritzer-Szekeres, M. ;
Redlberger-Fritz, M. ;
Mayer, F. J. .
CLINICAL MICROBIOLOGY AND INFECTION, 2019, 25 (08) :1032-1037
[28]   Very early diagnosis of chest pain by point-of-care testing: comparison of the diagnostic efficiency of a panel of cardiac biomarkers compared with troponin measurement alone in the RATPAC trial [J].
Collinson, Paul ;
Goodacre, Steve ;
Gaze, David ;
Gray, Alasdair ;
Arrowsmith, Charlotte ;
Barth, Julian ;
Benger, Jonathan ;
Bradburn, Mike ;
Capwell, Simon ;
Chater, Tim ;
Coats, Tim ;
Cooper, Cindy ;
Cooper, Mandy ;
Coyle, Judy ;
Cross, Liz ;
Dixon, Simon ;
Fitzgerald, Patrick ;
Gendall, Emma ;
Goodwin, Emma ;
Hall, Alistair ;
Hall, Kevin ;
Hassan, Taj ;
Humphrey, Julian ;
Julious, Steven ;
Kendall, Jason ;
Lawlor, Vanessa ;
Mackness, Sue ;
Meades, Yvonne ;
Newby, David ;
Newell, Dawn ;
Quartey, Doris ;
Robinson, Karen ;
Sibbick, Glen ;
Smith, Jason ;
Squire, Roz .
HEART, 2012, 98 (04) :312-318
[29]   Development of a Point-of-Care Test Based on Selenium Nanoparticles for Heart-Type Fatty Acid-Binding Proteins in Human Plasma and Blood [J].
Wang, Lanju ;
Wu, Mengli ;
Ma, Jingjing ;
Ma, Ziwei ;
Liang, Jiahui ;
Tao, Ningya ;
Ren, Yangguang ;
Shao, Shujun ;
Qi, Xin ;
Wang, Zhizeng .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2022, 17 :1273-1284
[30]   A Shake&Read distance-based microfluidic chip as a portable quantitative readout device for highly sensitive point-of-care testing [J].
Xie, Yi ;
Wei, Xiaofeng ;
Yang, Qizhen ;
Guan, Zhichao ;
Liu, Dan ;
Liu, Xuan ;
Zhou, Leiji ;
Zhu, Zhi ;
Lin, Zhenyu ;
Yang, Chaoyong .
CHEMICAL COMMUNICATIONS, 2016, 52 (91) :13377-13380