Highly Sensitive Lanthanide-Doped Nanoparticles-Based Point-of-Care Diagnosis of Human Cardiac Troponin I

被引:12
作者
Chen, Lu [1 ]
Zhou, Shan-Yong [2 ]
Zhu, Wei [3 ]
Liu, Sheng-Ping [4 ]
Zhang, Jing-Xi [5 ]
Zhuang, He [5 ]
Zhang, Jing-Ling [5 ]
Li, Yong-Sheng [6 ]
Gao, Fei [4 ]
机构
[1] Fujian Matern & Child Hlth Hosp, Dept Paediat, Fuzhou 350000, Peoples R China
[2] Chinese Acad Sci, Fujian Inst Res Struct Matter, Fujian Key Lab Nanomat, Fuzhou 350002, Peoples R China
[3] Fujian Med Univ, Shengli Clin Med Coll, Fujian Prov Hosp, Dept Urol, Fuzhou 350001, Peoples R China
[4] Fujian Med Univ Union Hosp, Fujian Inst Hematol, Fujian Prov Key Lab Hematol, Fuzhou 350001, Peoples R China
[5] Fujian Med Univ Union Hosp, Dept Clin Lab, Fuzhou 350001, Fujian, Peoples R China
[6] Fujian Med Univ Union Hosp, Dept Urol, Fuzhou 350001, Peoples R China
关键词
cardiac troponin I; GdVO; 4; 30% Eu NPs; lateral flow test strip; point-of-care test; ACUTE MYOCARDIAL-INFARCTION; HYDROTHERMAL SYNTHESIS; MAGNETIC-PROPERTIES; PHOTOLUMINESCENCE; LUMINESCENT; NANOCRYSTALS; PROTEIN; SIZE; EU;
D O I
10.2147/IJN.S346415
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Introduction: Cardiac troponin I (cTnI) has been regarded as a gold standard for early diagnosis and prognosis monitoring of acute myocardial infarction (AMI) in clinical practice. Owing to its low concentration in blood, accurate determination of cTnI often requires high sensitivity. However, current established point-of-care (POC) assays are insufficient to meet clinically analytical requirements due to their low sensitivity. Methods: To this end, we established a highly sensitive and reliable POC lateral flow strip based on lanthanide-doped nanoparticles (NPs) for cTnI determination in human blood samples. The capture of cTnI on the lateral flow strip was performed in a sandwich assay, where Eu3+-doped vanadate nanoparticles (GdVO4:30% Eu NPs) were used as luminescent probes to allow quantification. Results: Our platform realized the analytical sensitivity enhancement with limit-of-detection (LOD) as low as 17 pg mL-1 for cTnI detection, which was lower than the commercial counterpart; meanwhile, it displayed high specificity, excellent reproducibility and outstanding accuracy for analyzing clinical serum samples. Conclusion: Overall, this strategy provided an ultrasensitive, cost-effective and user-friendly platform for on-site cTnI detection, demonstrating the prospect of lanthanide-doped NPs-based POC diagnosis of disease-related biomarkers.
引用
收藏
页码:635 / 646
页数:12
相关论文
共 45 条
[21]   Deposition of GdVO4:Eu3+ nanoparticles on silica nanospheres by a simple sol-gel method [J].
Liu, GX ;
Hong, GY ;
Wang, JX ;
Dong, XT .
NANOTECHNOLOGY, 2006, 17 (13) :3134-3138
[22]   Near-Infrared Lanthanide-Doped Nanoparticles for a Low Interference Lateral Flow Immunoassay Test [J].
Liu, Qingyun ;
Cheng, Shengming ;
Chen, Rui ;
Ke, Jiaming ;
Liu, Yawei ;
Li, Yongfang ;
Feng, Wei ;
Li, Fuyou .
ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (04) :4358-4365
[23]   Peptide Functionalized Gold Nanoparticles with Optimized Particle Size and Concentration for Colorimetric Assay Development: Detection of Cardiac Troponin I [J].
Liu, Xiaohu ;
Wang, Yi ;
Chen, Peng ;
McCadden, Austin ;
Palaniappan, Alagappan ;
Zhang, Jinling ;
Liedberg, Bo .
ACS SENSORS, 2016, 1 (12) :1416-1422
[24]   Hybrids of Upconversion Nanoparticles and Silver Nanoclusters Ensure Superior Bactericidal Capability via Combined Sterilization [J].
Liu, Xun ;
Cheng, Zihan ;
Wen, Hui ;
Zhang, Shangqing ;
Chen, Mingli ;
Wang, Jianhua .
ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (46) :51285-51292
[25]   Tunable photoluminescence and magnetic properties of Dy3+ and Eu3+ doped GdVO4 multifunctional phosphors [J].
Liu, Yanxia ;
Liu, Guixia ;
Dong, Xiangting ;
Wang, Jinxian ;
Yu, Wensheng .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2015, 17 (40) :26638-26644
[26]   Lanthanide-doped luminescent nanoprobes: controlled synthesis, optical spectroscopy, and bioapplications [J].
Liu, Yongsheng ;
Tu, Datao ;
Zhu, Haomiao ;
Chen, Xueyuan .
CHEMICAL SOCIETY REVIEWS, 2013, 42 (16) :6924-6958
[27]   Fluorescent Nanoprobes with Oriented Modified Antibodies to Improve Lateral Flow Immunoassay of Cardiac Troponin I [J].
Lou, Doudou ;
Fan, Lin ;
Cui, Yan ;
Zhu, Yefei ;
Gu, Ning ;
Zhang, Yu .
ANALYTICAL CHEMISTRY, 2018, 90 (11) :6502-6508
[28]   Luminescent lanthanide nanoparticle-based imaging enables ultra-sensitive, quantitative and multiplexed in vitro lateral flow immunoassays [J].
Mousseau, F. ;
Feraudet Tarisse, C. ;
Simon, S. ;
Gacoin, T. ;
Alexandrou, A. ;
Bouzigues, C. I. .
NANOSCALE, 2021, 13 (35) :14814-14824
[29]   Optimal Detection of Acute Myocardial Injury and Infarction with Cardiac Troponin: Beyond the 99th Percentile, into the High-Sensitivity Era [J].
Mullins, Kristin E. ;
Christenson, Robert H. .
CURRENT CARDIOLOGY REPORTS, 2020, 22 (09)
[30]   A Cellulose Paper-Based Fluorescent Lateral Flow Immunoassay for the Quantitative Detection of Cardiac Troponin I [J].
Natarajan, Satheesh ;
Jayaraj, Joseph ;
Prazeres, Duarte Miguel F. .
BIOSENSORS-BASEL, 2021, 11 (02)