Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens
被引:125
作者:
Alio, Jorge L.
论文数: 0引用数: 0
h-index: 0
机构:
Vissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
Univ Miguel Hernandez, Div Ophthalmol, Alicante, SpainVissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
Alio, Jorge L.
[1
,2
]
Pinero, David P.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Alicante, Dept Opt, E-03080 Alicante, SpainVissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
Pinero, David P.
[3
]
Plaza-Puche, Ana B.
论文数: 0引用数: 0
h-index: 0
机构:Vissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
Plaza-Puche, Ana B.
Joanna Rodriguez, Maria
论文数: 0引用数: 0
h-index: 0
机构:Vissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
Joanna Rodriguez, Maria
机构:
[1] Vissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
PURPOSE: To compare visual acuity outcomes and ocular and intraocular optical quality in patients with a monofocal intraocular lens (IOL) or a multifocal IOL with rotational asymmetry. SETTING: Vissum Corporation, Alicante, Spain. DESIGN: Comparative case series. METHODS: Consecutive eyes of cataract patients were divided into 2 groups. One group received a Lentis Mplus LS-312 multifocal IOL and the other, an Acri.Smart 48S monofocal IOL. Distance and near visual acuities, contrast sensitivity, intraocular aberrations (global minus corneal aberrations), and defocus curves were evaluated preoperatively and postoperatively during a 3-month follow-up. RESULTS: The study evaluated 52 eyes of 29 patients (age range 36 to 87 years); 24 eyes were in multifocal IOL group and 28 eyes, in the monofocal IOL group. Both groups had a significant improvement in uncorrected and corrected distance visual acuities and in distance-corrected near visual acuity (DCNVA) postoperatively (P <=.04). The multifocal IOL group had significantly better uncorrected near acuity and DCNVA (Jaeger [J] 5 versus J2) (both P<.01). The defocus curves showed significantly better visual acuities in the multifocal group at several levels of defocus. The multifocal group had significantly higher amounts of postoperative intraocular primary coma (P<.01), especially in eyes with significant IOL tilt, although there were no significant differences in contrast sensitivity between the 2 IOL groups (P >=.25). CONCLUSIONS: The new-generation multifocal IOL restored distance, intermediate, and near visual function after cataract surgery. The optical quality with this type of IOL was particularly affected by IOL lilt and decentration.
机构:
Rio RioLaser Refract Surg Ctr, Rio De Janeiro, BrazilRio RioLaser Refract Surg Ctr, Rio De Janeiro, Brazil
Crema, Armando S.
Walsh, Aileen
论文数: 0引用数: 0
h-index: 0
机构:
Rio RioLaser Refract Surg Ctr, Rio De Janeiro, BrazilRio RioLaser Refract Surg Ctr, Rio De Janeiro, Brazil
Walsh, Aileen
Ventura, Bruna V.
论文数: 0引用数: 0
h-index: 0
机构:
Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
Altino Ventura Fdn, Recife, PE, BrazilRio RioLaser Refract Surg Ctr, Rio De Janeiro, Brazil
Ventura, Bruna V.
Santhiago, Marcony R.
论文数: 0引用数: 0
h-index: 0
机构:
Rio RioLaser Refract Surg Ctr, Rio De Janeiro, Brazil
Univ Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
Univ Fed Rio de Janeiro, Dept Ophthalmol, Rio De Janeiro, BrazilRio RioLaser Refract Surg Ctr, Rio De Janeiro, Brazil