Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens

被引:125
|
作者
Alio, Jorge L. [1 ,2 ]
Pinero, David P. [3 ]
Plaza-Puche, Ana B.
Joanna Rodriguez, Maria
机构
[1] Vissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[3] Univ Alicante, Dept Opt, E-03080 Alicante, Spain
关键词
HIGHER-ORDER ABERRATIONS; WAVE-FRONT ANALYSIS; CONTRAST SENSITIVITY; CATARACT-SURGERY; RETINAL STRAYLIGHT; CLINICAL-OUTCOMES; IMAGE QUALITY; IMPLANTATION; RESTOR; DISTANCE;
D O I
10.1016/j.jcrs.2010.08.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual acuity outcomes and ocular and intraocular optical quality in patients with a monofocal intraocular lens (IOL) or a multifocal IOL with rotational asymmetry. SETTING: Vissum Corporation, Alicante, Spain. DESIGN: Comparative case series. METHODS: Consecutive eyes of cataract patients were divided into 2 groups. One group received a Lentis Mplus LS-312 multifocal IOL and the other, an Acri.Smart 48S monofocal IOL. Distance and near visual acuities, contrast sensitivity, intraocular aberrations (global minus corneal aberrations), and defocus curves were evaluated preoperatively and postoperatively during a 3-month follow-up. RESULTS: The study evaluated 52 eyes of 29 patients (age range 36 to 87 years); 24 eyes were in multifocal IOL group and 28 eyes, in the monofocal IOL group. Both groups had a significant improvement in uncorrected and corrected distance visual acuities and in distance-corrected near visual acuity (DCNVA) postoperatively (P <=.04). The multifocal IOL group had significantly better uncorrected near acuity and DCNVA (Jaeger [J] 5 versus J2) (both P<.01). The defocus curves showed significantly better visual acuities in the multifocal group at several levels of defocus. The multifocal group had significantly higher amounts of postoperative intraocular primary coma (P<.01), especially in eyes with significant IOL tilt, although there were no significant differences in contrast sensitivity between the 2 IOL groups (P >=.25). CONCLUSIONS: The new-generation multifocal IOL restored distance, intermediate, and near visual function after cataract surgery. The optical quality with this type of IOL was particularly affected by IOL lilt and decentration.
引用
收藏
页码:241 / 250
页数:10
相关论文
共 50 条
  • [31] Visual function and mobility after multifocal versus monofocal intraocular lens implantation
    Hall, Courtney D.
    Barnes, Claire S.
    Gutherie, Audrey H.
    Lynch, Mary G.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2022, 105 (01) : 70 - 76
  • [32] Comparison of Visual Performance of Multifocal Intraocular Lenses with Same Material Monofocal Intraocular Lenses
    Yamauchi, Tomofusa
    Tabuchi, Hitoshi
    Takase, Kosuke
    Ohsugi, Hideharu
    Ohara, Zaigen
    Kiuchi, Yoshiaki
    PLOS ONE, 2013, 8 (06):
  • [33] Cataract surgery with new monofocal intraocular lens enhanced for intermediate vision and standard monofocal intraocular lens for retinal disorder
    Hwang, Hye Seong
    Lee, Hwanho
    Park, Jin Hyoung
    Chae, Ju Byung
    Kim, Dong Yoon
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [34] Clinical outcomes with an aspheric monofocal and a new enhanced monofocal intraocular lens with modified optical profile
    Oege Goslings
    Henk Veraart
    Janny van de Laar-Muskens
    David P. Piñero
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 2315 - 2326
  • [35] Effect of illumination on visual function after monofocal and multifocal intraocular lens implantation
    M A Elgohary
    A B Beckingsale
    Eye, 2006, 20 : 144 - 149
  • [36] Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
    Chen, Xiangfei
    Zhao, Ming
    Shi, Yuhua
    Yang, Liping
    Lu, Yan
    Huang, Zhenping
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (04) : 285 - 291
  • [37] Comparison of new monofocal innovative and standard monofocal intraocular lens after phacoemulsification
    Unsal, Ugur
    Sabur, Huri
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (01) : 273 - 282
  • [38] Visual and optical quality of enhanced intermediate monofocal versus standard monofocal intraocular lens
    Garzon, Nuria
    Poyales, Francisco
    Albarran-Diego, Cesar
    Rico-del-Viejo, Laura
    Perez-Sanz, Lidia
    Garcia-Montero, Maria
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (11) : 3617 - 3625
  • [39] Visual and optical quality of enhanced intermediate monofocal versus standard monofocal intraocular lens
    Nuria Garzón
    Francisco Poyales
    César Albarrán-Diego
    Laura Rico-del-Viejo
    Lidia Pérez-Sanz
    María García-Montero
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 3617 - 3625
  • [40] Visual and Refractive Outcomes Following Exchange of an Opacified Multifocal Intraocular Lens
    Stewart, Stephen A.
    McNeely, Richard N.
    Chan, Wing C.
    Moore, Jonathan E.
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1883 - 1891