Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens

被引:125
|
作者
Alio, Jorge L. [1 ,2 ]
Pinero, David P. [3 ]
Plaza-Puche, Ana B.
Joanna Rodriguez, Maria
机构
[1] Vissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[3] Univ Alicante, Dept Opt, E-03080 Alicante, Spain
关键词
HIGHER-ORDER ABERRATIONS; WAVE-FRONT ANALYSIS; CONTRAST SENSITIVITY; CATARACT-SURGERY; RETINAL STRAYLIGHT; CLINICAL-OUTCOMES; IMAGE QUALITY; IMPLANTATION; RESTOR; DISTANCE;
D O I
10.1016/j.jcrs.2010.08.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual acuity outcomes and ocular and intraocular optical quality in patients with a monofocal intraocular lens (IOL) or a multifocal IOL with rotational asymmetry. SETTING: Vissum Corporation, Alicante, Spain. DESIGN: Comparative case series. METHODS: Consecutive eyes of cataract patients were divided into 2 groups. One group received a Lentis Mplus LS-312 multifocal IOL and the other, an Acri.Smart 48S monofocal IOL. Distance and near visual acuities, contrast sensitivity, intraocular aberrations (global minus corneal aberrations), and defocus curves were evaluated preoperatively and postoperatively during a 3-month follow-up. RESULTS: The study evaluated 52 eyes of 29 patients (age range 36 to 87 years); 24 eyes were in multifocal IOL group and 28 eyes, in the monofocal IOL group. Both groups had a significant improvement in uncorrected and corrected distance visual acuities and in distance-corrected near visual acuity (DCNVA) postoperatively (P <=.04). The multifocal IOL group had significantly better uncorrected near acuity and DCNVA (Jaeger [J] 5 versus J2) (both P<.01). The defocus curves showed significantly better visual acuities in the multifocal group at several levels of defocus. The multifocal group had significantly higher amounts of postoperative intraocular primary coma (P<.01), especially in eyes with significant IOL tilt, although there were no significant differences in contrast sensitivity between the 2 IOL groups (P >=.25). CONCLUSIONS: The new-generation multifocal IOL restored distance, intermediate, and near visual function after cataract surgery. The optical quality with this type of IOL was particularly affected by IOL lilt and decentration.
引用
收藏
页码:241 / 250
页数:10
相关论文
共 50 条
  • [21] Clinics Outcomes Following Implantation of A New Aspheric Monofocal Intraocular Lens
    Yigit, Ulviye
    Cavusoglu, Ercan
    Onur, I. Umut
    Kaya, F. Selin
    JOURNAL OF ACADEMIC RESEARCH IN MEDICINE-JAREM, 2019, 9 : S35 - S40
  • [22] Comparison of visual performance with an aspheric intraocular lens and a spherical intraocular lens
    Thiagarajan, Manickam
    McClenaghan, Rory
    Anderson, David F.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) : 1993 - 2000
  • [23] Refractive outcomes after multifocal intraocular lens exchange
    Kim, Eric J.
    Sajjad, Ahmar
    de Oca, Ildamaris Montes
    Koch, Douglas D.
    Wang, Li
    Weikert, Mitchell P.
    Al-Mohtaseb, Zaina N.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (06) : 761 - 766
  • [24] Comparison of 3-month visual outcomes of a new multifocal intraocular lens vs a trifocal intraocular lens
    Dick, H. Burkhard
    Ang, Robert E.
    Corbett, Dean
    Hoffmann, Peter
    Tetz, Manfred
    Villarrubia, Alberto
    Palomino, Carlos
    Castillo-Gomez, Alfredo
    Tsai, Linda
    Thomas, Eugenia K.
    Janakiraman, Priya
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (11) : 1270 - 1276
  • [25] Clinical outcomes of a new diffractive multifocal intraocular lens
    Toygar, Baha
    Kiziloglu, Ozge Yabas
    Toygar, Okan
    Hacimustafaoglu, Ali Murat
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (12) : 1844 - 1850
  • [26] Dual intraocular lens implantation: Monofocal lens in the bag and additional diffractive multifocal lens in the sulcus
    Gerten, Georg
    Kermani, Omid
    Schmiedt, Karl
    Farvili, Elham
    Foerster, Andreas
    Oberheide, Uwe
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12) : 2136 - 2143
  • [27] Visual performance and patient satisfaction of multifocal contact lenses in eyes undergoing monofocal intraocular Lens implantation
    Kamiya, Kazutaka
    Fujimura, Fusako
    Ando, Wakako
    Iijima, Kei
    Shoji, Nobuyuki
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (03) : 218 - 221
  • [28] Comparison of an aspheric monofocal intraocular lens with the new generation monofocal lens using defocus curve
    Yangzes, Sonam
    Kamble, Neha
    Grewal, Sartaj
    Grewal, Satinder P. S.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) : 3025 - 3029
  • [29] Double-pass system analysis of the visual outcomes and optical performance of an apodized diffractive multifocal intraocular lens
    Moreno, Luis J.
    Pinero, David P.
    Alio, Jorge L.
    Fimia, Antonio
    Plaza, Ana B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12) : 2048 - 2055
  • [30] Effect of illumination on visual function after monofocal and multifocal intraocular lens implantation
    Elgohary, MA
    Beckingsale, AB
    EYE, 2006, 20 (02) : 144 - 149