Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens

被引:128
作者
Alio, Jorge L. [1 ,2 ]
Pinero, David P. [3 ]
Plaza-Puche, Ana B.
Joanna Rodriguez, Maria
机构
[1] Vissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[3] Univ Alicante, Dept Opt, E-03080 Alicante, Spain
关键词
HIGHER-ORDER ABERRATIONS; WAVE-FRONT ANALYSIS; CONTRAST SENSITIVITY; CATARACT-SURGERY; RETINAL STRAYLIGHT; CLINICAL-OUTCOMES; IMAGE QUALITY; IMPLANTATION; RESTOR; DISTANCE;
D O I
10.1016/j.jcrs.2010.08.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual acuity outcomes and ocular and intraocular optical quality in patients with a monofocal intraocular lens (IOL) or a multifocal IOL with rotational asymmetry. SETTING: Vissum Corporation, Alicante, Spain. DESIGN: Comparative case series. METHODS: Consecutive eyes of cataract patients were divided into 2 groups. One group received a Lentis Mplus LS-312 multifocal IOL and the other, an Acri.Smart 48S monofocal IOL. Distance and near visual acuities, contrast sensitivity, intraocular aberrations (global minus corneal aberrations), and defocus curves were evaluated preoperatively and postoperatively during a 3-month follow-up. RESULTS: The study evaluated 52 eyes of 29 patients (age range 36 to 87 years); 24 eyes were in multifocal IOL group and 28 eyes, in the monofocal IOL group. Both groups had a significant improvement in uncorrected and corrected distance visual acuities and in distance-corrected near visual acuity (DCNVA) postoperatively (P <=.04). The multifocal IOL group had significantly better uncorrected near acuity and DCNVA (Jaeger [J] 5 versus J2) (both P<.01). The defocus curves showed significantly better visual acuities in the multifocal group at several levels of defocus. The multifocal group had significantly higher amounts of postoperative intraocular primary coma (P<.01), especially in eyes with significant IOL tilt, although there were no significant differences in contrast sensitivity between the 2 IOL groups (P >=.25). CONCLUSIONS: The new-generation multifocal IOL restored distance, intermediate, and near visual function after cataract surgery. The optical quality with this type of IOL was particularly affected by IOL lilt and decentration.
引用
收藏
页码:241 / 250
页数:10
相关论文
共 48 条
[21]   Visual results following implantation of a refractive multifocal IOL in one eye and a diffractive multifocal IOL in the contralateral eye [J].
Goes, Frank Joseph .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) :300-305
[22]  
Gonzalez C, 1996, OPHTHAL PHYSL OPT, V16, P19, DOI 10.1016/0275-5408(94)00010-7
[23]   Retinal Straylight and Complaint Scores 18 Months After Implantation of the AcrySof Monofocal and ReSTOR Diffractive Intraocular Lenses [J].
Hofmann, Thomas ;
Zuberbuhler, Bruno ;
Cervino, Alejandro ;
Montes-Mico, Robert ;
Haefliger, Eduard .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (06) :485-492
[24]   EVALUATION OF CONTRAST ACUITY AND DEFOCUS CURVE IN BIFOCAL AND MONOFOCAL INTRAOCULAR LENSES [J].
KNORZ, MC ;
CLAESSENS, D ;
SCHAEFER, RC ;
SEIBERTH, V ;
LIESENHOFF, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (04) :513-523
[25]   European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens [J].
Kohnen, T ;
Allen, D ;
Boureau, C ;
Dublineau, P ;
Hartmann, C ;
Mehdorn, E ;
Rozot, P ;
Tassinari, G .
OPHTHALMOLOGY, 2006, 113 (04) :578-584
[26]   Wavefront analysis of higher-order aberrations in patients with cataract [J].
Kuroda, T ;
Fujikado, T ;
Maeda, N ;
Oshika, T ;
Hirohara, Y ;
Mihashi, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03) :438-444
[27]   Wavefront analysis in eyes with nuclear or cortical cataract [J].
Kuroda, T ;
Fujikado, T ;
Maeda, N ;
Oshika, T ;
Hirohara, Y ;
Mihashi, T .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (01) :1-9
[28]   Multifocal versus monofocal intraocular lenses in cataract surgery [J].
Leyland, M ;
Zinicola, E .
OPHTHALMOLOGY, 2003, 110 (09) :1789-1798
[29]   Distance and near contrast sensitivity function after multifocal intraocular lens implantation [J].
Montés-Micó, R ;
Alió, JL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04) :703-711
[30]   Effect of intraocular lens asphericity on vertical coma aberration [J].
Nanavaty, Mayank A. ;
Spalton, David J. ;
Marshall, John .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (02) :215-221