Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens

被引:128
作者
Alio, Jorge L. [1 ,2 ]
Pinero, David P. [3 ]
Plaza-Puche, Ana B.
Joanna Rodriguez, Maria
机构
[1] Vissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[3] Univ Alicante, Dept Opt, E-03080 Alicante, Spain
关键词
HIGHER-ORDER ABERRATIONS; WAVE-FRONT ANALYSIS; CONTRAST SENSITIVITY; CATARACT-SURGERY; RETINAL STRAYLIGHT; CLINICAL-OUTCOMES; IMAGE QUALITY; IMPLANTATION; RESTOR; DISTANCE;
D O I
10.1016/j.jcrs.2010.08.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual acuity outcomes and ocular and intraocular optical quality in patients with a monofocal intraocular lens (IOL) or a multifocal IOL with rotational asymmetry. SETTING: Vissum Corporation, Alicante, Spain. DESIGN: Comparative case series. METHODS: Consecutive eyes of cataract patients were divided into 2 groups. One group received a Lentis Mplus LS-312 multifocal IOL and the other, an Acri.Smart 48S monofocal IOL. Distance and near visual acuities, contrast sensitivity, intraocular aberrations (global minus corneal aberrations), and defocus curves were evaluated preoperatively and postoperatively during a 3-month follow-up. RESULTS: The study evaluated 52 eyes of 29 patients (age range 36 to 87 years); 24 eyes were in multifocal IOL group and 28 eyes, in the monofocal IOL group. Both groups had a significant improvement in uncorrected and corrected distance visual acuities and in distance-corrected near visual acuity (DCNVA) postoperatively (P <=.04). The multifocal IOL group had significantly better uncorrected near acuity and DCNVA (Jaeger [J] 5 versus J2) (both P<.01). The defocus curves showed significantly better visual acuities in the multifocal group at several levels of defocus. The multifocal group had significantly higher amounts of postoperative intraocular primary coma (P<.01), especially in eyes with significant IOL tilt, although there were no significant differences in contrast sensitivity between the 2 IOL groups (P >=.25). CONCLUSIONS: The new-generation multifocal IOL restored distance, intermediate, and near visual function after cataract surgery. The optical quality with this type of IOL was particularly affected by IOL lilt and decentration.
引用
收藏
页码:241 / 250
页数:10
相关论文
共 48 条
[11]   Evidence for delayed presbyopia after photorefractive keratectomy for myopia [J].
Artola, A ;
Patel, S ;
Schimchak, P ;
Ayala, MJ ;
Ruiz-Moreno, JM ;
Alió, JL .
OPHTHALMOLOGY, 2006, 113 (05) :735-741
[12]  
Bellucci Roberto, 2005, Curr Opin Ophthalmol, V16, P33, DOI 10.1097/00055735-200502000-00006
[13]   Retinal straylight in patients with monofocal and multifocal intraocular lenses [J].
Cervino, Alejandro ;
Hosking, Sarah L. ;
Montes-Mico, Robert ;
Alio, Jorge L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03) :441-446
[15]   Decentred optical axes and aberrations along principal visual field meridians [J].
Charman, W. Neil ;
Atchison, David A. .
VISION RESEARCH, 2009, 49 (14) :1869-1876
[16]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[17]   Corrected and Uncorrected Near and Distance Vision with ReSTOR® Compared to Monofocal Intraocular Lens Implantation after Cataract Surgery: A Pooled Analysis [J].
Cochener, Beatrice ;
Arnould, Benoit ;
Viala, Muriel ;
de Climens, Aude Roborel ;
Berdeaux, Gilles .
OPHTHALMOLOGICA, 2009, 223 (02) :128-135
[18]   History and development of the apodized diffractive intraocular lens [J].
Davison, James A. ;
Simpson, Michael J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :849-858
[19]  
Dick H Burkhard, 2005, Curr Opin Ophthalmol, V16, P8, DOI 10.1097/00055735-200502000-00004
[20]  
Doshi JB, 2001, J REFRACT SURG, V17, P414