Effects of Acute Pump Speed Changes on Cerebral Hemodynamics in Patients With an Implantable Continuous-Flow Left Ventricular Assist Devices

被引:0
作者
Konarik, Miroslav [1 ,2 ]
Sramko, Marek [3 ,4 ]
Dorazilova, Zora [3 ]
Blaha, Martin [3 ]
Netuka, Ivan [1 ,5 ]
Ivak, Peter [1 ,6 ,7 ]
Maly, Jiri [1 ]
Szarszoi, Ondrej [1 ,8 ]
机构
[1] Inst Clin & Expt Med, Dept Cardiac Surg, Videnska 1958-9, Prague 14021, Czech Republic
[2] Charles Univ Prague, Fac Med 1, Dept Physiol, Prague, Czech Republic
[3] Inst Clin & Expt Med, Dept Cardiol, Prague, Czech Republic
[4] Charles Univ Prague, Fac Med 1, Dept Internal Med 2, Prague, Czech Republic
[5] Charles Univ Prague, Fac Med 1, Dept Surg 2, Dept Cardiovasc Surg, Prague, Czech Republic
[6] Charles Univ Prague, Fac Med 3, Dept Physiol, Prague, Czech Republic
[7] Charles Univ Prague, Fac Med 1, Dept Surg 2, Dept Cardiovasc Surg, Prague, Czech Republic
[8] Charles Univ Prague, Fac Med 2, Dept Pathophysiol, Prague, Czech Republic
关键词
LVAD; Continuous flow; Plethysmography; Cerebral autoregulation; AUTOREGULATION; PULSATILITY;
D O I
10.33549/physiolres.934738
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Mechanical circulatory support (MCS) with an implantable left ventricular assist device (LVAD) is an established therapeutic option for advanced heart failure. Most of the currently used LVADs generate a continuous stream of blood that decreases arterial pulse pressure. This study investigated whether a change of the pulse pressure during different pump speed settings would affect cerebral autoregulation and thereby affect cerebral blood flow (CBF). The study included 21 haemodynamically stable outpatients with a continuous-flow LVAD (HeartMate II, Abbott, USA) implanted a median of 6 months before the study (interquartile range 3 to 14 months). Arterial blood pressure (measured by finger plethysmography) was recorded simultaneously with CBF (measured by transcranial Doppler ultrasound) during baseline pump speed (8900 rpm [IQR 8800; 9200]) and during minimum and maximum tolerated pump speeds (8000 rpm [IQR 8000; 8200] and 9800 rpm [IQR 9800; 10 000]). An increase in LVAD pump speed by 800 rpm [IQR 800; 1000] from the baseline lead to a significant decrease in arterial pulse pressure and cerebral blood flow pulsatility (relative change -24 % and -32 %, both p < 0.01), but it did not affect mean arterial pressure and mean CBF velocity (relative change 1 % and -1.7 %, p=0.1 and 0.7). In stable patients with a continuous-flow LVAD, changes of pump speed settings within a clinically used range did not impair static cerebral autoregulation and cerebral blood flow.
引用
收藏
页码:831 / 839
页数:9
相关论文
共 50 条
  • [21] Prevention and Treatment of Thrombotic and Hemorrhagic Complications in Patients Supported by Continuous-Flow Left Ventricular Assist Devices
    Loyaga-Rendon R.Y.
    Jani M.
    Fermin D.
    McDermott J.K.
    Vancamp D.
    Lee S.
    Current Heart Failure Reports, 2017, 14 (6) : 465 - 477
  • [22] Clinical management of continuous-flow left ventricular assist devices in advanced heart failure
    Slaughter, Mark S.
    Pagani, Francis D.
    Rogers, Joseph G.
    Miller, Leslie W.
    Sun, Benjamin
    Russell, Stuart D.
    Starling, Randall C.
    Chen, Leway
    Boyle, Andrew J.
    Chillcott, Suzanne
    Adamson, Robert M.
    Blood, Margaret S.
    Camacho, Margarita T.
    Idrissi, Katherine A.
    Petty, Michael
    Sobieski, Michael
    Wright, Susan
    Myers, Timothy J.
    Farrar, David J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (04) : S1 - S39
  • [23] Continuous-Flow Left Ventricular Assist Device Implantation in Patients With a Small Left Ventricle
    Kawabori, Masashi
    Kurihara, Chitaru
    Sugiura, Tadahisa
    Cohn, William E.
    Civitello, Andrew B.
    Frazier, O. Howard
    Morgan, Jeffrey A.
    ANNALS OF THORACIC SURGERY, 2018, 105 (03) : 799 - 806
  • [24] Effect of pulsatile and nonpulsatile flow on cerebral perfusion in patients with left ventricular assist devices
    Cornwell, William K., III
    Tarumi, Takashi
    Aengevaeren, Vincent L.
    Ayers, Colby
    Divanji, Punag
    Fu, Qi
    Palmer, Dean
    Drazner, Mark H.
    Meyer, Dan M.
    Bethea, Brian T.
    Hastings, Jeffrey L.
    Fujimoto, Naoki
    Shibata, Shigeki
    Zhang, Rong
    Markham, David W.
    Levine, Benjamin D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (12) : 1295 - 1303
  • [25] Factors Influencing the Rate of Flow Through Continuous-Flow Left Ventricular Assist Devices at Rest and With Exercise
    Levine, Benjamin D.
    Cornwell, William K., III
    Drazner, Mark H.
    JACC-HEART FAILURE, 2014, 2 (04) : 331 - 334
  • [26] Noninvasive measurement of arterial blood pressure in patients with continuous-flow left ventricular assist devices: a systematic review
    Paulino A. Alvarez
    Rakesh Ponnapureddy
    Dinesh Voruganti
    Ernesto Ruiz Duque
    Alexandros Briasoulis
    Heart Failure Reviews, 2021, 26 : 47 - 55
  • [27] Noninvasive measurement of arterial blood pressure in patients with continuous-flow left ventricular assist devices: a systematic review
    Alvarez, Paulino A.
    Ponnapureddy, Rakesh
    Voruganti, Dinesh
    Duque, Ernesto Ruiz
    Briasoulis, Alexandros
    HEART FAILURE REVIEWS, 2021, 26 (01) : 47 - 55
  • [28] The Impact of Acute Exercise on Hemostasis and Angiogenesis Mediators in Patients With Continuous-Flow Left Ventricular Assist Devices: A Prospective Observational Pilot Study
    Chan, Chris H. H.
    Passmore, Margaret R.
    Tronstad, Oystein
    Seale, Helen
    Bouquet, Mahe
    White, Nicole
    Teruya, Jun
    Hogan, Airlie
    Platts, David
    Chan, Wandy
    Dashwood, Alexander M.
    Mcgiffin, David C.
    Maiorana, Andrew J.
    Hayward, Christopher S.
    Simmonds, Michael J.
    Tansley, Geoff D.
    Suen, Jacky Y.
    Fraser, John F.
    Meyns, Bart
    Fresiello, Libera
    Jacobs, Steven
    ASAIO JOURNAL, 2025, 71 (01) : 11 - 20
  • [29] Cerebral Blood Flow Autoregulation Is Preserved After Continuous-Flow Left Ventricular Assist Device Implantation
    Ono, Masahiro
    Joshi, Brijen
    Brady, Kenneth
    Easley, R. Blaine
    Kibler, Kathy
    Conte, John
    Shah, Ashish
    Russell, Stuart D.
    Hogue, Charles W.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2012, 26 (06) : 1022 - 1028
  • [30] Continuous-Flow Left Ventricular Assist Device and the Right Ventricle
    Puhlman, Mark
    AACN ADVANCED CRITICAL CARE, 2012, 23 (01) : 86 - 90