Effects of Acute Pump Speed Changes on Cerebral Hemodynamics in Patients With an Implantable Continuous-Flow Left Ventricular Assist Devices

被引:0
作者
Konarik, Miroslav [1 ,2 ]
Sramko, Marek [3 ,4 ]
Dorazilova, Zora [3 ]
Blaha, Martin [3 ]
Netuka, Ivan [1 ,5 ]
Ivak, Peter [1 ,6 ,7 ]
Maly, Jiri [1 ]
Szarszoi, Ondrej [1 ,8 ]
机构
[1] Inst Clin & Expt Med, Dept Cardiac Surg, Videnska 1958-9, Prague 14021, Czech Republic
[2] Charles Univ Prague, Fac Med 1, Dept Physiol, Prague, Czech Republic
[3] Inst Clin & Expt Med, Dept Cardiol, Prague, Czech Republic
[4] Charles Univ Prague, Fac Med 1, Dept Internal Med 2, Prague, Czech Republic
[5] Charles Univ Prague, Fac Med 1, Dept Surg 2, Dept Cardiovasc Surg, Prague, Czech Republic
[6] Charles Univ Prague, Fac Med 3, Dept Physiol, Prague, Czech Republic
[7] Charles Univ Prague, Fac Med 1, Dept Surg 2, Dept Cardiovasc Surg, Prague, Czech Republic
[8] Charles Univ Prague, Fac Med 2, Dept Pathophysiol, Prague, Czech Republic
关键词
LVAD; Continuous flow; Plethysmography; Cerebral autoregulation; AUTOREGULATION; PULSATILITY;
D O I
10.33549/physiolres.934738
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Mechanical circulatory support (MCS) with an implantable left ventricular assist device (LVAD) is an established therapeutic option for advanced heart failure. Most of the currently used LVADs generate a continuous stream of blood that decreases arterial pulse pressure. This study investigated whether a change of the pulse pressure during different pump speed settings would affect cerebral autoregulation and thereby affect cerebral blood flow (CBF). The study included 21 haemodynamically stable outpatients with a continuous-flow LVAD (HeartMate II, Abbott, USA) implanted a median of 6 months before the study (interquartile range 3 to 14 months). Arterial blood pressure (measured by finger plethysmography) was recorded simultaneously with CBF (measured by transcranial Doppler ultrasound) during baseline pump speed (8900 rpm [IQR 8800; 9200]) and during minimum and maximum tolerated pump speeds (8000 rpm [IQR 8000; 8200] and 9800 rpm [IQR 9800; 10 000]). An increase in LVAD pump speed by 800 rpm [IQR 800; 1000] from the baseline lead to a significant decrease in arterial pulse pressure and cerebral blood flow pulsatility (relative change -24 % and -32 %, both p < 0.01), but it did not affect mean arterial pressure and mean CBF velocity (relative change 1 % and -1.7 %, p=0.1 and 0.7). In stable patients with a continuous-flow LVAD, changes of pump speed settings within a clinically used range did not impair static cerebral autoregulation and cerebral blood flow.
引用
收藏
页码:831 / 839
页数:9
相关论文
共 50 条
  • [1] Effects of continuous-flow left ventricular assist devices on cerebral hemodynamics
    Karahan, Mehmet
    Kocabeyoglu, Sinan Sabit
    Kervan, Umit
    Sert, Dogan Emre
    Aygun, Emre
    Tola, Muharrem
    Demirkan, Burcu
    Mungan, Semra
    Kursun, Oguzhan
    Catav, Zeki
    Pac, Mustafa
    ARTIFICIAL ORGANS, 2020, 44 (05) : 457 - 464
  • [2] Design changes in continuous-flow left ventricular assist devices and life-threatening pump malfunctions
    Soltani, Sajjad
    Kaufmann, Friedrich
    Vierecke, Juliane
    Kretzschmar, Alexandra
    Hennig, Ewald
    Stein, Julia
    Hetzer, Roland
    Krabatsch, Thomas
    Potapov, Evgenij V.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (06) : 984 - 989
  • [3] Physiologic and Pathologic Changes in Patients with Continuous-Flow Ventricular Assist Devices
    John, Ranjit
    Boyle, Andrew
    Pagani, Frank
    Miller, Leslie
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2009, 2 (02) : 154 - 158
  • [4] Physiologic and Pathologic Changes in Patients with Continuous-Flow Ventricular Assist Devices
    Ranjit John
    Andrew Boyle
    Frank Pagani
    Leslie Miller
    Journal of Cardiovascular Translational Research, 2009, 2 : 154 - 158
  • [5] Neurologic Events in Continuous-Flow Left Ventricular Assist Devices
    Kadakkal, Ajay
    Najjar, Samer S.
    CARDIOLOGY CLINICS, 2018, 36 (04) : 531 - +
  • [6] Clinical Implications of Physiologic Flow Adjustment in Continuous-Flow Left Ventricular Assist Devices
    Tchantchaleishvili, Vakhtang
    Luc, Jesica G. Y.
    Cohan, Caitlin M.
    Phan, Kevin
    Hubbert, Laila
    Day, Steven W.
    Masey, H. Todd
    ASAIO JOURNAL, 2017, 63 (03) : 241 - 250
  • [7] The Physiological Rationale for Incorporating Pulsatility in Continuous-Flow Left Ventricular Assist Devices
    Grosman-Rimon, Liza
    Billia, Filio
    Kobulnik, Jeremy
    Bar-Ziv, Stacey Pollock
    Cherney, David Z.
    Rao, Vivek
    CARDIOLOGY IN REVIEW, 2018, 26 (06) : 294 - 301
  • [8] Hematologic Effects of Continuous Flow Left Ventricular Assist Devices
    Slaughter, Mark S.
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2010, 3 (06) : 618 - 624
  • [9] Hematologic Effects of Continuous Flow Left Ventricular Assist Devices
    Mark S. Slaughter
    Journal of Cardiovascular Translational Research, 2010, 3 : 618 - 624
  • [10] Device-device interaction between cardiac implantable electronic devices and continuous-flow left ventricular assist devices
    Tanawuttiwat, Tanyanan
    Das, Mithilesh K.
    Miller, John M.
    Guglin, Maya E.
    HEART RHYTHM, 2023, 20 (06) : 918 - 926