Indications for transvenous lead extraction and its procedural and early outcomes in elderly patients: a single-center experience

被引:3
作者
Zabek, Andrzej [1 ]
Boczar, Krzysztof [1 ]
Debskil, Maciej [1 ]
Pfitzner, Roman [2 ,3 ]
Ulmanl, Mateusz [1 ]
Holcman, Katarzyna [2 ,4 ]
Kostkiewicz, Magdalena [2 ,4 ]
Musial, Robert [5 ]
Lelakowski, Jacek [1 ,2 ]
Malecka, Barbara [1 ,2 ]
机构
[1] John Paul 2 Hosp, Dept Electrocardiol, Ul Pradnicka 80, PL-31202 Krakow, Poland
[2] Jagiellonian Univ, Inst Cardiol, Med Coll, Krakow, Poland
[3] John Paul 2 Hosp, Dept Cardiovasc Surg, Krakow, Poland
[4] John Paul 2 Hosp, Dept Cardiac & Vasc Dis, Krakow, Poland
[5] John Paul 2 Hosp, Dept Anesthesiol & Intens Therapy, Krakow, Poland
来源
POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ | 2020年 / 130卷 / 03期
关键词
cardiovascular implantable electronic devices; effectiveness; elderly; safety; transvenous lead extraction; PREDICTORS; MORTALITY; DEFIBRILLATOR; PACEMAKER; REGISTRY; SAFETY; 30-DAY; OLDER;
D O I
10.20452/pamw.15182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
INTRODUCTION Due to the prolonged survival of patients with cardiovascular implantable electronic devices, leads often need to be removed in elderly individuals. OBJECTIVES We aimed to analyze indications for transvenous lead extraction (TLE), procedure effectiveness and safety, as well as 30-day follow-up in younger patients (<= 80 years) and octogenarians (>80 years). PATIENTS AND METHODS This prospective study included 667 patients who underwent TLE: 90 octogenarians (13.5%) at a mean age of 83.8 (range, 80.4-93) years and 577 younger patients (86.5%) at a mean age of 64.2 (range, 18.9-79.9) years. RESULTS Octogenarians had a greater number of comorbidities, fewer implantable cardioverter-defibrillators implanted, and more frequently had infection as an indication for TLE, as compared with younger patients (33.3% vs 17.1%; P <0.001). In octogenarians, 138 leads were extracted, as compared with 894 leads in younger patients. Octogenarians and younger patients had similar rates of complete lead removal (98.6% and 97.1%, respectively; P = 0.48), total procedural success (97.8% and 96%, respectively; P = 0.7), major complications (0% and 1.6%, respectively; P = 0.45), and minor complications (2.2% and 1.6%, respectively; P = 0.45). There was 1 death associated with TLE in younger patients. Non-procedure-related deaths within 30 days after TLE were more frequent in octogenarians than in younger patients (5.6% vs 1.9%; P = 0.04). CONCLUSIONS We showed that TLE in patients older than 80 years seems to be as effective as in younger patients; however, it is associated with significantly higher non-procedure-related 30-day mortality.
引用
收藏
页码:216 / 224
页数:9
相关论文
共 50 条
[21]   Lead Extraction of Cardiac Rhythm Devices: A Report of a Single-Center Experience [J].
Azevedo, Ana Isabel ;
Primo, Joao ;
Goncalves, Helena ;
Oliveira, Marco ;
Adao, Luis ;
Santos, Elisabeth ;
Ribeiro, Jose ;
Fonseca, Marlene ;
Dias, Adelaide V. ;
Vouga, Luis ;
Ribeiro, Vasco Gama .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2017, 4
[22]   Safety and effectiveness of transvenous lead extraction in elderly patients [J].
Kutarski, Andrzej ;
Polewczyk, Anna ;
Boczar, Krzysztof ;
Zabek, Andrzej ;
Polewczyk, Maciej .
CARDIOLOGY JOURNAL, 2014, 21 (01) :47-52
[23]   Reimplantation and long-term mortality after transvenous lead extraction in a high-risk, single-center cohort [J].
Zsigmond, Elod-Janos ;
Miklos, Marton ;
Vida, Adorjan ;
Benak, Attila ;
Makai, Attila ;
Schvartz, Noemi ;
Klausz, Gergely ;
Hegedus, Zoltan ;
Bogats, Gabor ;
Saghy, Laszlo ;
Vamos, Mate .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (04) :847-855
[24]   Lead Removal Without Extraction Tools: A Single-Center Experience [J].
Lima, Neiberg de Alcantara ;
Cunha, Gisele Schinaider ;
de Menezes, Natalia Soares ;
da Silva Junior, Evilasio Leobino ;
de Vasconcelos Lima, Carol Cavalcante ;
Vitorino Sampaio, Stela Maria .
BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2019, 34 (04) :458-463
[25]   Safety and efficacy of transvenous lead extractions for noninfectious superfluous leads in a Japanese population: A single-center experience [J].
Higuchi, Satoshi ;
Shoda, Morio ;
Saito, Satoshi ;
Kanai, Miwa ;
Kataoka, Shohei ;
Yazaki, Kyoichiro ;
Yagishita, Daigo ;
Ejima, Koichiro ;
Hagiwara, Nobuhisa .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (12) :1517-1523
[26]   Indications and Outcomes of Renal Biopsies in Children: A Single-Center 12-Year Experience [J].
Cakici, Evrim Kargin ;
Yazilitas, Fatma ;
Uner, Cigdem ;
Can, Gokce ;
Kurt-Sukur, Eda Didem ;
Gungor, Tulin ;
Celikkaya, Evra ;
Eroglu, Fehime Kara ;
Karakaya, Deniz ;
Arda, Nilufer ;
Bulbul, Mehmet .
TURKISH JOURNAL OF NEPHROLOGY, 2019, 28 (04) :250-256
[27]   Efficacy and Safety of Transarterial Radioembolization in Elderly Patients with Hepatocellular Carcinoma: A Single-Center Experience [J].
Karaogullarindan, Umit ;
Gumurdulu, Yuksel ;
Uskudar, Oguz ;
Odabas, Emre ;
Guler, Hasan Selim ;
Geckalan, Cansu ;
Benli, Burcu Arslan ;
Delik, Anil ;
Ozdemir, Asena Ayca ;
Kuran, Sedef .
TURKISH JOURNAL OF GASTROENTEROLOGY, 2024, 35 (03)
[28]   CIED implantation in elderly patients: a single-center experience [J].
Ilov, Nikolay N. ;
Nechepurenko, Anatoly A. ;
Abdulkadyrov, Albert M. ;
Paskeev, Damir R. ;
Asfandiyarov, Timur F. ;
Tarasov, Dmitry G. .
JOURNAL OF GERIATRIC CARDIOLOGY, 2018, 15 (06) :460-462
[29]   Cardiac Perforation and Lead Dislodgement after Implantation of a MR-Conditional Pacing Lead: A Single-Center Experience [J].
Elmouchi, Darryl A. ;
Rosema, Shelly ;
Vanoosterhout, Stacie M. ;
Khan, Mohsin ;
Davis, Alan T. ;
Gauri, Andre J. ;
Finta, Bohuslav ;
Woelfel, Alan K. ;
Chalfoun, Nagib T. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (01) :4-10
[30]   Clinical features and therapeutic outcomes of patients with acromegaly: Single-center experience [J].
Dusek, T. ;
Kastelan, D. ;
Melada, A. ;
Baretic, M. ;
Polovina, T. Skoric ;
Perkovic, Z. ;
Giljevic, Z. ;
Jelcic, J. ;
Paladino, J. ;
Aganovic, I. ;
Korsic, M. .
JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2011, 34 (11) :E382-E385